FTWIC-2235June, 2009locations of concealed Junction boxes, all piping, valves and underground utilities shallbe redlined as to their existence and location.C. At the conclusion of construction, the <strong>Contract</strong>or shall turn over their two sets of as-builtdrawings to the FAA COR.PART 3.00EXECUTION3.01 FIELD MEASUREMENTS:<strong>Contract</strong>or is responsible for making complete field measurements. Check all dimensions at thejob site for components requiring fit to surrounding conditions. Check shop drawings andindicate the actual dimension available at all locations.3.02 SAFETY REQUIREMENTS:A. <strong>Contract</strong>or is solely responsible for the safety and welfare of workmen on the project andthe general public around the construction site. Take precautions to adequately safeguardthe safety of all persons on or near the site. Comply with the regulations of the"Occupational Safety and Health Standards", and other safety regulations.B. Provide and maintain barricades, guard rails, covered walkways, and other protectivedevices necessary to warn and protect the workmen and general public from hazards atthe construction site. Maintain barricades around open ditches. Provide barricades atroads and passageways at dangerous conditions. Provide flares or flashing lights at suchbarriers at night. All barricades and protective devices shall comply with safetyrequirements and insurance carrier's requirements.3.03 FIRE PROTECTION:A. Maintain fire extinguishers at construction site in sufficient number to adequately protectthe structures during construction. Provide at least one fire extinguisher at eachconstruction office. Provide at least one fire extinguisher for welders or other tradesusing open flames in the execution of their work.B. Maintain the telephone number of the local fire department. Keep number postedconspicuously near telephone.3.04 DISRUPTION TO SERVICES:A. Disruption to existing utilities, piping, or electrical services must be held to a minimum.<strong>Contract</strong>or shall carefully plan work in a manner that such disruptions are coordinatedwith the <strong>Contract</strong>ing Officer. Any operation which requires shut down of some portionof the facilities operation must be in compliance with Section 01030 SPECIALPROVISIONS.B. Storm sewers and sanitary sewers shall be maintained in service at all times. In the eventthat it becomes necessary to disrupt one of the utilities, provide temporary service aroundthe construction or otherwise construct the structure in a manner that the flow is notcurtailed.01041-2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!