1.05 STANDARDS:.FTWIC-2235June 20097. Each primary protective device required for the delta-to-wye connectedtransformer shall be selected so the characteristics of the operating band is withinthe transformer parameters, which shall include a parameter equivalent to 58% ofthe withstand point to afford protection for secondary line-to-ground faults. Thetransformer damage curve shall be included for the transformer when the selectedprotective device is not within the associated parameters.8. Molded case circuit breakers shall be separated from each other and theassociated primary protective device by a 16% current margin for coordinationand protection in the event of secondary line-to-line faults.9. The protective device characteristics or operating bands shall be suitablyterminated to reflect the actual symmetrical fault currents sensed by the device.10. The <strong>Contract</strong>or shall note that the drawings and <strong>specifications</strong> indicate thegeneral requirements for motors and motor starting equipment. High voltage andlow voltage equipment furnished shall be determined in accordance with theresults of the protection coordination study.11. The study shall include verification of equipment ratings and settings. Theresults of the study shall be submitted before preparing shop drawings. The<strong>Contract</strong>or shall keep the study up to date with any project changes, which affectthe study, and submit the revised study for approval of changes.12. The study shall include a comprehensive table of all protective devices,associated ratings, and designated settings of all adjustable components.A. Electrical work shall be executed in accordance with local, State and national codes,ordinances and regulations which have jurisdiction or authority over the work. Ifconflicts occur between FAA documents and any other document, FAA requirementsshall be used. If conflicts occur between other documents, the most stringent shall apply.The applicable provisions and recommendations of the following standards shall becomplied with as if written here in their entirety:1. National Electrical Manufacturer Association (NEMA)2. American Society for Testing and Materials (ASTM)3. National Fire Protection Association (NFPA)4. National Electrical Safety Code (NESC)5. Institute of Electrical and Electronic Engineers (IEEE)6. National Electrical Code (NEC)7. Underwriters' Laboratories (UL)8. American National Standards Institute (ANSI)9. Standard Building Code10. Occupational Safety and Health <strong>Administration</strong> (OSHA)11. Local utility companies12. Town of Houma, LA Electrical Ordinance13. State of Louisiana Seismic Code16010-4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!