Table A-2 Explanation <strong>and</strong> Recommendations <strong>for</strong> <strong>the</strong> List of Key CALMET <strong>Model</strong> Options/Continued<br />

Option Parameter Recommend<br />

value<br />

Explanation <strong>and</strong> Justification<br />

Diagnostic module domain-averaged lapse IDIOPT2 0 Computed internally using twice daily upper air data or, prognostic fields.<br />

rate option<br />

DIAG.DAT file is no longer used.<br />

Upper air station to use <strong>for</strong> domain scale<br />

lapse rate<br />

Depth through which <strong>the</strong> domain scale lapse<br />

rate is computed<br />

IUPT -1 Use spatially varying potential temperature lapse rate<br />

ZUPT<br />

200m<br />

57<br />

Only used when temperature lapse rate is computed internally from available<br />

upper air or gridded prognostic data. Recommended ZUPT value is based on<br />

model testing <strong>and</strong> should not be changed without supporting data.<br />

Initial Guess Wind Field IDIOPT3 0 Computed internally from observations <strong>and</strong> or prognostic winds<br />

Upper air station to use <strong>for</strong> initial guess field<br />

(IGF).<br />

IUPWND -1 Use 3-D varying initial guess field. Only used if when using observational<br />

data to define <strong>the</strong> IGF (i.e., NOOBS=0). Default means use <strong>the</strong> 3-D initial<br />

guess field.<br />

ZUPWND 1 – 1000m Option not used with 3-D IGF.<br />

Bottom <strong>and</strong> top of layer through which <strong>the</strong><br />

domain-scale winds are computed<br />

Observed surface wind components <strong>for</strong> wind<br />

field module<br />

IDIOPT4 0 Keep at recommended value. DIAG.DAT file is no longer used.<br />

Observed upper air wind components IDIOPT5 0 Keep at recommended value. DIAG.DAT file is no longer used.