01.12.2012 Views

Generic Guidance and Optimum Model Settings for the CALPUFF ...

Generic Guidance and Optimum Model Settings for the CALPUFF ...

Generic Guidance and Optimum Model Settings for the CALPUFF ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LIST OF TABLES<br />

Page<br />

Table 2-1. Table shows <strong>the</strong> difference in ef<strong>for</strong>t required by <strong>the</strong> user to run CALMET in three different<br />

modes, (1) <strong>the</strong> most simple a No-Obs mode, (2) a Hybrid approach which combines<br />

observations with prognostic model data, <strong>and</strong> (3) an Observations only approach – which<br />

requires <strong>the</strong> most decisions <strong>and</strong> ef<strong>for</strong>t by <strong>the</strong> user.....................................................................8<br />

Table 2-2. <strong>Model</strong> Option Switches <strong>for</strong> No-Obs Simulations......................................................................9<br />

Table 2-3. Tabulated List of Various Methods <strong>for</strong> Including Meteorological Data into CALMET. The<br />

list is detailed in order of decreasing preference. ....................................................................15<br />

Table 3-1. Annual Average SO 2 Concentrations (µg/m 3 ) at Alcoa, TN <strong>for</strong> 1976 <strong>and</strong> 1977. Observed <strong>and</strong><br />

predicted concentrations using <strong>the</strong> BLP, <strong>CALPUFF</strong> <strong>and</strong> AERMOD models.........................29<br />

Table A-1. An Explanation of <strong>the</strong> 7 Critical User-Defined, Site Specific Parameters When Using<br />

Observational Data in CALMET.............................................................................................51<br />

Table A-2. Explanation <strong>and</strong> Recommendations <strong>for</strong> <strong>the</strong> List of Key CALMET <strong>Model</strong> Options ...............54<br />

Table A-3. Explanation <strong>and</strong> Recommendations <strong>for</strong> <strong>the</strong> Overwater Surface Fluxes Switches...................58<br />

Table A-4. Explanation <strong>and</strong> Recommendations <strong>for</strong> <strong>the</strong> List of Key CALUFF <strong>Model</strong> Options ................61<br />

Table of Contents vi

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!