12.07.2015 Views

VP-RS2BLNX Protocol Converter - Bosch

VP-RS2BLNX Protocol Converter - Bosch

VP-RS2BLNX Protocol Converter - Bosch

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

CCTV | <strong>VP</strong>-<strong>RS2BLNX</strong> <strong>Protocol</strong> <strong>Converter</strong><strong>VP</strong>-<strong>RS2BLNX</strong><strong>Protocol</strong> <strong>Converter</strong>• RS-232 and RS-485 to Bilinxconverter• Compatible with Dinion, Dinion XF ,Autodome cameras• Robust Design• Wide Range power supplyThe <strong>VP</strong>-<strong>RS2BLNX</strong> is a protocol converter that allows theintegration of remotely accessible cameras for control andset-up into an (existing) RS-232 or RS-485 infrastructure.When connected to <strong>Bosch</strong> cameras with Bilinx capabilities,the <strong>VP</strong>-<strong>RS2BLNX</strong> converts RS-232 or RS-485 messages intoBilinx communication data. In this way <strong>Bosch</strong> cameras withBilinx can be controlled directly from computers, digitalrecorders or video management systems.The <strong>VP</strong>-<strong>RS2BLNX</strong> is suitable for use with Dinion, Dinion XFand all Bilinx enabled AutoDome cameras. Applicationstypically include Traffic Management systems and VideoContent Analysis systems, where the camera performanceneeds to be optimized during operation.Security you can rely on.


2 | <strong>VP</strong>-<strong>RS2BLNX</strong> <strong>Protocol</strong> <strong>Converter</strong>Installation/Configuration NotesRS-232 configuration exampleRS-485b configuration exampleNote: For RS-485 communication a maximum of 64transceivers is permissible on a single bus.Ordering InformationModel & Description<strong>VP</strong>-<strong>RS2BLNX</strong> <strong>Protocol</strong> <strong>Converter</strong>RS-232 / RS-485 infrastructure, Bilinx to USB adaptor for use withconfiguration tool for dome/camerasTechnical SpecificationsElectricalPower12-28 VAC (50/60 Hz) and 12-40 VDC (polarityindependent). Galvanically insulated from video,RS-232 ground and casing.SpeedRS-4859600 baudRS-2329600 or 4800 baud selectableVideo connectors BNC connections, passive loop through, highimpedance, Video input 1Vpp nominal, 2 Vppmax.<strong>Protocol</strong>The serial protocol is described in the Serial<strong>Protocol</strong> Description. This document is availableupon request from <strong>Bosch</strong> Security Systems.Dimensions 88.5 x 100 x 28 mm(L x W x H) (3.38 x 3.94 x 1.1 inch)Temperature rangeoperating/storage -20°C to +50°C (-4°F to 122 °F)Comparison tableMin. Typ. Max. UnitPower supply input voltage AC 10.8 - 28 <strong>VP</strong>ower supply input voltage DC 10.8 - 40 <strong>VP</strong>ower consumption - 1.3 2 WRS-232Input voltage operating range -24 - 24 VInput logic threshold LOW 0.8 1.2 - VInput logic threshold HIGH - 1.7 2.4 VInput hysteresis 0.2 0.5 1 VInput resistance 3 5 7 kkkOhmOutput voltage swing-7.8 - 7.8 V(with 3 kOhm load)Output resistance 300 - - ohmData rate 4.8 9.6 - Kbits/sRS-485Input voltage operating range -7 12 VDifferential input logic- -0.2 - Vthreshold LOWDifferential input logic- 0.2 - Vthreshold HIGHDifferential input hysteresis - 70 - mVInput resistance 24 - - kOhmDifferential output (no load) - - 5 VCommon-mode output- - 3 V(load = 50 ohm)Data rate - 9.6 - Kbit/sAmericas:<strong>Bosch</strong> Security Systems130 Perinton ParkwayFairport, New York, 14450, USAPhone:+1 585 223 4060+1 800 289 0096security.sales@us.bosch.comhttp://www.boschsecurity.usEurope, Middle East, Africa:<strong>Bosch</strong> Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone:+31 (0) 40 27 83955Fax:+31 (0) 40 27 86668emea.securitysystems@bosch.comhttp://www.boschsecurity.comAsia-Pacific:<strong>Bosch</strong> Security Systems Pte Ltd38C Jalan PemimpinSingapore 577180Phone:+65 6319 3450Fax:+65 6319 3499apr.securitysystems@bosch.comhttp://www.boschsecurity.comData subject to change without notice | Printed in Netherlands | | 26. May 2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!