12.07.2015 Views

Systems house-building Systems house-building (SW6) - J.E. StorkAir

Systems house-building Systems house-building (SW6) - J.E. StorkAir

Systems house-building Systems house-building (SW6) - J.E. StorkAir

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Renovation and replacement<strong>Systems</strong> <strong>house</strong>-<strong>building</strong><strong>Systems</strong> <strong>house</strong>-<strong>building</strong> (<strong>SW6</strong>)Collective individual mechanical extractionUnievent system for individual mechanical ventilationin multi-storey dwellings. Every dwelling is equippedwith a domestic fan, type CMF or CMFe, a ductsystem, a non-powered extractor hood andadjustable ventilation valves in the rooms to beconnected. On the delivery side, the fan is connectedat an angle of 90° to a collective duct, to which areconnected all the vertically-adjacent dwellings. A nonreturnvalve and fire-retardant materials must also befitted on the delivery side between the fan and themain duct. A very low resistance Unievent extractorhood is fitted to the collective duct on the roof. Thishood is constructed in such a way that the volume ofextracted air remains more or less constantregardless of wind speed.VENTILATIE-UNITPagina- CMF 37- CMFe 45- CMFe R 45ACCESSOIRESPaginaVENTILATIEVENTIELEN- STB (luchtafvoer) 565- STC (luchtafvoer) 571- STK (luchtafvoer) 573- STV (luchtafvoer) 577WASEMKAP- WK 600-3 583- ExSense 585LUCHTTERUGSLAGKLEP- UK 125 581KEUKENBOX- SKB 581REGEL- EN SCHAKELAPP.Pagina3 STANDEN SCHAKELAAR- SA 1-3V 521RADIOGRAFISCHE BESTURING- RFZ 513Unievent kapLevering derdenCMF CMFe STB STK WK 600-3 UK 125 SKB SA RFZ1


Renovation and replacement<strong>Systems</strong> <strong>house</strong>-<strong>building</strong><strong>Systems</strong> <strong>house</strong>-<strong>building</strong> (<strong>SW6</strong>)Selecting fan and duct diameterThe choice of fan is determined by the choice of thesystem, the volume of air to be extracted and the lossof pressure. The loss of pressure on both the suctionand delivery side of the fan up until the main duct canbe determined through calculation. The tables belowgive the diameters of the main ducts, the air volumesand the number of storeys, whereby the maximumpressure loss in the main duct, including theextraction hood, amounts to 30Pa. and 50Parespectively. The collective ventilation ducts must beof the same diameter from the top to the bottomstoreys!GIW HighlightsWhen ventilating, bear in mind the specific notesdescribed in the GIW. Please visit the website for asummary.Aantal verdiepingen bij een drukverlies in hethoofdkanaal van 30 PaØ mm/ 225 250 280 315 355 400 450 500 560 630 710 800m³/h150 5 6 7 8 11 13 16 19 23 27 - -175 4 5 6 7 9 11 13 16 20 24 28 -200 3 4 4 5 7 8 10 12 15 18 22 -225 3 4 4 5 7 8 10 12 15 18 22 -250 3 3 4 5 6 7 9 11 13 17 20 28275 2 3 3 4 6 7 8 10 12 15 18 25300 2 2 3 4 5 6 7 9 11 14 17 24350 - 2 3 3 4 5 6 8 10 12 16 20400 - 2 2 3 4 4 5 7 9 11 14 18Numbers floors head los at headcanal from 50 PaØ mm/ 225 250 280 315 355 400 450 500 560 630 710 800m³/h150 6 7 9 11 14 16 20 24 28 - - -175 5 6 8 9 12 14 17 21 25 30 - -200 4 5 7 8 10 12 15 18 22 27 32 -225 4 5 6 7 9 11 13 16 20 24 29 -250 3 4 5 6 8 10 12 14 18 21 26 35275 3 4 5 6 7 9 11 13 16 19 24 32300 2 3 4 5 6 7 9 12 15 19 24 30350 2 3 3 4 5 6 8 10 13 16 20 25400 - 2 3 3 4 6 7 9 11 14 18 222

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!