12.07.2015 Views

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

It is possible to adjust the system to completely eliminate heating <strong>and</strong> coolingequipment cycling based on the outside air limitations, if this type of systemoperation is desired. Figure 6 illustrates two ways to eliminate overlappingdeadb<strong>and</strong> <strong>and</strong> the associated equipment cycling. Note that eliminating overlappingdeadb<strong>and</strong> may impact the control per<strong>for</strong>mance of certain zones during otherperiods of system operation.Heating Lockout =72°F (22°C)No Overlapping Deadb<strong>and</strong>Cooling Lockout =72°F (22°C)Outside Air TemperatureHeating Lockout =70°F (21°C)5F° (3C°)Deadb<strong>and</strong>;No Heating<strong>and</strong>No CoolingCooling Lockout =75°F (24°C)FIG:no_ovrlppng_ddbndOutside Air TemperatureFigure 6: No Overlapping Deadb<strong>and</strong>Seasonal ChangeoverHeating <strong>and</strong> cooling equipment cycling during seasonal changeover is almostinevitable with a VAV zoning control system, if any degree of occupancy com<strong>for</strong>tis to be maintained. A properly set up system delivers com<strong>for</strong>t to conflicting zonedem<strong>and</strong>s during seasonal changeover by alternating between heating <strong>and</strong> coolingat the rooftop controller.Unwanted heating <strong>and</strong> cooling switchovers are eliminated by either using <strong>and</strong>authorizing terminal reheat, or by limiting the rooftop controller heating <strong>and</strong>cooling capacity throughput based on the outside air temperature (H lock <strong>and</strong>C lock parameters). Note that limiting the rooftop controller heating <strong>and</strong> coolingcapacity throughput based on the outside air temperature may impact the controlper<strong>for</strong>mance of certain zones in the system, since the required heating or coolingcapacity is no longer available due to the lockout conditions.40<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!