Table 12: <strong>TEC</strong>2664Z-2 Rooftop <strong>Control</strong>ler Installer Configuration Menu (Part 4 of 5)ParameterAppearingon DisplayH lock 5C lock 52/4eventAux contProg recOcc CL 4Occ HT 4Unocc CL 4Description <strong>and</strong> DefaultDiscontinues Heating operation inresponse to the outside airtemperature. Requires that anoutside air temperature sensor beinstalled <strong>and</strong> connected.Default: 120.0°F/49.0°CDiscontinues Cooling operation inresponse to the outside airtemperature. Requires that anoutside air temperature sensor beinstalled <strong>and</strong> connected.Default: -40.0°F/-40.0°CSets the number <strong>and</strong> configurationof events.Default: 2 eventsEnergizes peripheral devices(lighting equipment, exhaust fans,<strong>and</strong> economizers).Default: n.o.Enables Progressive recovery.Default: offNote: Progressive recovery isautomatically disabled ifDI1 is configured <strong>for</strong>remote NSB.If network communication is lostwith the zone controller(s), thereturn air sensor controls the rooftopcontroller to maintain this Coolingsetpoint.Default: 72.0°F/22.0°CIf network communication is lostwith the zone controller(s), thereturn air sensor controls the rooftopcontroller to maintain this Heatingsetpoint.Default: 70.0°F/21.0°CIf network communication is lostwith the zone controller(s), thereturn air sensor controls the rooftopcontroller to maintain thisUnoccupied Cooling setpoint.Default: 82.0°F/28.0°CSelection OptionsRange: -15.0°F/-26.0°C to 120.0°F/49.0°CRange: -40.0°F/-40.0°C to 95.0°F/35.0°C(2 events): Sets up programming <strong>for</strong> the following:Event 1 is <strong>for</strong> Occupied setpoints.Event 2 is <strong>for</strong> Unoccupied setpoints.(4 events): Sets up programming <strong>for</strong> the following:Event 1 is <strong>for</strong> Occupied setpoints.Event 2 is <strong>for</strong> Unoccupied setpoints.Event 3 is <strong>for</strong> Occupied setpoints.Event 4 is <strong>for</strong> Unoccupied setpoints.(n.c.): Contact open = Occupied; contact closed = Unoccupied(n.o.): Contact closed = Occupied; contact open = UnoccupiedNote: The contact toggles with the internal Occupied/Unoccupiedschedule (or the remote NSB contact if DI1 is used).(on): Progressive recovery enabledNote: The programmed Occupied schedule time is the time atwhich the desired Occupied temperature is attained. Therooftop controller automatically optimizes the equipment starttime.(off): Progressive recovery disabledNote: The programmed Occupied schedule time is the time atwhich the system restarts.Range: 54.0°F/12.0°C to 100.0°F/37.5°CRange: 40.0°F/4.5°C to 90.0°F/32.0°CRange: 54.0°F/12.0°C to 100.0°F/37.5°C<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!