2. Check that the system is in the heating mode. To do so, press the SCROLLbutton on the rooftop controller to show the local Zone Sequence = Heatprompt.3. Adjust the appropriate setpoints to ensure that the voting zones call <strong>for</strong> heating.4. Adjust the local setpoint of the currently balanced zone controller to itsminimum value (<strong>for</strong> example, 60°F [16°C] or at least 7 to 8F° [3.5 to 4C°]lower than the current room temperature), to drive the zone damper to itsminimum position.5. Set the Min Pos parameter to the desired value, as required to balance theminimum airflow.To balance the maximum airflow:1. Set the outside heating lockout value (H lock parameter) at the rooftopcontroller to ensure that local system heating is allowed.2. Check that the system is in the heating mode. To do so, press the SCROLLbutton on the rooftop controller to show the local Zone Sequence = Heatprompt.3. Adjust the appropriate setpoints to ensure that the voting zones call <strong>for</strong> heating.4. Adjust the local setpoint of the currently balanced zone controller to itsmaximum value (<strong>for</strong> example, 80°F [27°C] or at least 7 to 8F° [3.5 to 4C°]higher than the current room temperature), to drive the zone damper to itsmaximum position.5. Set the Max Pos parameter to the desired value, as required to balance themaximum airflow.To balance the maximum heat flow:1. Set the outside cooling lockout value (C lock parameter) at the rooftopcontroller to ensure that local system cooling is allowed.2. Set the outside reheat lockout value (AO2 OALK or BO5 OALK parameter)at the zone controller to ensure that local reheat is allowed.3. Check that the system is in the cooling mode. To do so, press the SCROLLbutton on the rooftop controller to show the local Zone Sequence = Coolprompt.4. Adjust the appropriate setpoints to ensure that the voting zones call <strong>for</strong> cooling.5. Adjust the local setpoint of the currently balanced zone controller to itsmaximum value (<strong>for</strong> example, 80°F [27°C] or at least 7 to 8F° [3.5 to 4C°]higher than the current room temperature), to drive the zone damper to itsminimum position.6. Set the MaxH<strong>TP</strong>os parameter to the desired value, as required to balance themaximum heat flow.30<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!