Maximum Position Adjustment (Max Pos Parameter)This parameter sets the maximum position of the zone damper to deliver themaximum amount of hot or cold air to the zone in all conditions. When poweredup, the damper never opens above the maximum position setting.Note: Use the Max Pos parameter to set the maximum amount of hot airdelivered to the zone; not the MaxH<strong>TP</strong>os parameter. See Maximum HeatFlow Adjustment (MaxH<strong>TP</strong>os Parameter) on page 28 <strong>for</strong> a description ofthe MaxH<strong>TP</strong>os parameter.The Max Pos parameter is also used to set the maximum amount of cold airdelivered to the zone.Maximum Heat Flow Adjustment (MaxH<strong>TP</strong>os Parameter)Many assume the MaxH<strong>TP</strong>os parameter sets the maximum amount of hot airdelivered to the zone, but that is not a correct assumption. Instead, the Max Posparameter sets both the maximum amount of hot air <strong>and</strong> the maximum amount ofcold air delivered to the zone. See Maximum Position Adjustment(Max Pos Parameter) on page 28 <strong>for</strong> a description of the Max Pos parameter.The MaxH<strong>TP</strong>os parameter sets the minimum heating position of the zone damper,to maximize hot airflow on a call <strong>for</strong> reheat with cold supply air. The MaxH<strong>TP</strong>osfunction is only used if the local reheat configuration (RehtConf parameter) is setto any value other than (0): None (no local reheat). Table 9 includes the maximumheat flow adjustments <strong>for</strong> the various reheat stages <strong>and</strong> reheat output time bases.Table 9: Maximum Heat Flow Adjustment (Part 1 of 2)Reheat Stage(RehtConfParameter)Time Base <strong>for</strong>Reheat Output(BO5 TimeParameter)Maximum Heat Flow Adjustment(MaxH<strong>TP</strong>os Parameter)(0): None N/A Leave the maximum heat flow at its default setting of30%, or adjust it to any other setting. The maximumheat flow adjustment is not used in this scenario.(1): Analog DuctReheat OnlyN/AAdjust the maximum heat flow to any value higher thanthe current selected minimum position.Example: The minimum airflow is set at 25% <strong>and</strong> themaximum heat flow is set at 75%. If the primary air iscold, when the PI heating loop (<strong>and</strong> analog output)goes from 0 to 100%, the zone damper moves linearlyfrom 25 to 75% open.28<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!