TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Table 3: <strong>System</strong> Mode Calculation with Three Voting Zones (Example 1)Heat ActionVotingZone 1VotingZone 2VotingZone 3Current Heat Dem<strong>and</strong> 50% 0% 0%Heat Weight Set 50% 100% 100%Resulting Heat Weight to Rooftop <strong>Control</strong>ler 25% 0% 0%Highest Resulting Heat Weight of Three Zones 25%Average of Three Highest Resulting Heat Weights 8.3%Cool ActionVotingZone 1VotingZone 2VotingZone 3Current Cool Dem<strong>and</strong> 0% 100% 100%Cool Weight Set 100% 100% 50%Resulting Cool Weight to Rooftop <strong>Control</strong>ler 0% 100% 50%Highest Resulting Cool Weight of Three Zones 100%Average Cool Weight of Three Highest Zones 50%Table 3 shows that the resulting heat <strong>and</strong> cool weight used by the rooftop controller<strong>for</strong> the three voting zones is different, meaning different heating <strong>and</strong> cooling actionbased on the configuration of the rooftop controller.Table 4: <strong>System</strong> Mode Calculation with Three Voting Zones (Example 2)Heat ActionVotingZone 1VotingZone 2VotingZone 3Current Heat Dem<strong>and</strong> 100% 0% 0%Heat Weight Set 100% 100% 100%Resulting Heat Weight to Rooftop <strong>Control</strong>ler 100% 0% 0%Highest Resulting Heat Weight of Three Zones 100%Average of Three Highest Resulting Heat Weights 33.3%Cool ActionVotingZone 1VotingZone 2VotingZone 3Current Cool Dem<strong>and</strong> 0% 100% 100%Cool Weight Set 100% 75% 75%Resulting Cool Weight to Rooftop <strong>Control</strong>ler 0% 75% 75%Highest Resulting Cool Weight of Three Zones 75%Average Cool Weight of Three Highest Zones 50%Table 4 shows that the resulting heat <strong>and</strong> cool weight used by the rooftop controller<strong>for</strong> the three voting zones is different, meaning different heating <strong>and</strong> cooling actionbased on the configuration of the rooftop controller.• If the control type of the rooftop controller is set to the highest dem<strong>and</strong>, theaction of the rooftop controller is heating.• If the control type of the rooftop controller is set to the average of the threehighest dem<strong>and</strong>s, the action of the rooftop controller is cooling.<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin23

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!