Table 2: <strong>TEC</strong>2647Z-2 <strong>and</strong> <strong>TEC</strong>2647Z-2+PIR Zone <strong>Control</strong>ler InstallerConfiguration Menu (Part 6 of 7)ParameterAppearingon DisplayDescription <strong>and</strong> Default Selection OptionsTOccTimeCal RSDeadb<strong>and</strong>Heat maxCool minMin PosMax PosMaxH<strong>TP</strong>os 6PIHT Wei 7Sets the duration of the TemporaryOccupancy Time when the heatingor cooling setpoints in the Occupiedmode are established by:• an Override Function enabled inthe Main User Menu (when thezone controller is in theUnoccupied mode)• a temporary heating or coolingsetpointDefault: 2.0 hrsSets the desired room airtemperature sensor calibration(offset). The offset can be added toor subtracted from the actualdisplayed room temperature.Default: 0.0F°/0.0C°Sets the minimum deadb<strong>and</strong>between heating <strong>and</strong> coolingsetpoints.Default: 2.0F°/1.0C°Sets the Occupied, <strong>St<strong>and</strong></strong>by, <strong>and</strong>Unoccupied maximum Heatingsetpoint values.Default: 90.0°F/32.0°CSets the Occupied, <strong>St<strong>and</strong></strong>by, <strong>and</strong>Unoccupied minimum Coolingsetpoint values.Default: 54.0°F/12.0°CSets the minimum position of thezone damper.Default: 10%Sets the maximum position of thezone damper.Default: 100%Sets the minimum heating positionof the zone damper to maximize hotairflow on a call <strong>for</strong> reheat with coldsupply air.Default: 30%Sets the weight of the PI heatingdem<strong>and</strong> of a zone, used in thePI heating calculation of the zonecontroller.Default: 100%Range: 0.0 to 12.0 hrsNote: When adjusting the TOccTime, press the UP/DOWN arrowkeys to change the time in 1-hour increments; press <strong>and</strong> holdthe UP/DOWN arrow keys to change the time in 10-hourincrements.Range: -5.0F°/-2.5C° to 5.0F°/2.5C° adjustable in 1.0F°/0.5C°incrementsRange: 2.0F°/1.0C° to 5.0F°/2.5C° adjustable in 1.0F°/0.5C°incrementsRange: 40.0°F/4.5°C to90.0°F/32.0°CRange: 54.0°F/12.0°C to100.0°F/37.5°CRange: 0 to 100%Range: 0 to 100%Range: 0 to 100%Note: When adjusting thetemperature, press theUP/DOWN arrow keys tochange the temperature in0.5F°/0.5C° increments;press <strong>and</strong> hold theUP/DOWN arrow keys tochange the temperature in5.0F°/5.0C° increments.Note: When adjusting the damperposition, press theUP/DOWN arrow keys tochange the position in 1%increments; press <strong>and</strong> holdthe UP/DOWN arrow keys tochange the position in 10%increments.(0%): PI Heating Weight of 0%(25%): PI Heating Weight of 25%(50%): PI Heating Weight of 50%(75%): PI Heating Weight of 75%(100%): PI Heating Weight of 100%Note: A zone that includes a special application (such as a serverroom, mechanical room, or cafeteria) may affect the averageheating dem<strong>and</strong> at the rooftop controller level, resulting indiscom<strong>for</strong>t in other zones. Setting the PI heating weight to0% eliminates this problem.20<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!