12.07.2015 Views

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Monitoring Inputs BI2 <strong>and</strong> UI3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15<strong>TEC</strong>2647Z-2 <strong>and</strong> <strong>TEC</strong>2647Z-2+PIR Zone <strong>Control</strong>ler Operation <strong>and</strong> Strategy. . . . . . . . 21PIR Onboard Occupancy Sensor (<strong>TEC</strong>2647Z-2+PIR Model) . . . . . . . . . . . . . . . . . . . . . . . 22Dem<strong>and</strong>-Based Heating <strong>and</strong> Cooling <strong>System</strong> . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Overrides <strong>and</strong> Zone <strong>Control</strong>ler User Interface Lockouts . . . . . . . . . . . . . . . . . . . . . . . . . . . 24Zone Setpoint Limits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25Heating <strong>and</strong> Cooling Weight Zone Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Minimum, Maximum, <strong>and</strong> Heat Flow Adjustments. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Minimum Position Adjustment (Min Pos Parameter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Maximum Position Adjustment (Max Pos Parameter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Maximum Heat Flow Adjustment (MaxH<strong>TP</strong>os Parameter) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Balancing the Minimum, Maximum, <strong>and</strong> Heat Flow Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Terminal Reheat Lockout. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Configuring the <strong>TEC</strong>2664Z-2 Rooftop <strong>Control</strong>ler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Configuring Input DI1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32<strong>TEC</strong>2664Z-2 Rooftop <strong>Control</strong>ler Operation <strong>and</strong> Strategy. . . . . . . . . . . . . . . . . . . . . . . . 36Data Exchange between the Rooftop <strong>Control</strong>ler <strong>and</strong> the Zones . . . . . . . . . . . . . . . . . . . . . 36Occupancy <strong>and</strong> Overrides . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37Rooftop <strong>Control</strong>ler User Interface Lockouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Rooftop <strong>Control</strong>ler Heating <strong>and</strong> Cooling Supply Air Temperature Lockouts . . . . . . . . . . . . 38Rooftop <strong>Control</strong>ler Heating <strong>and</strong> Cooling Outside Air Temperature Lockouts . . . . . . . . . . . 39Seasonal Changeover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40Bypass Damper <strong>Control</strong> <strong>and</strong> Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42<strong>TEC</strong>2647Z-2 <strong>and</strong> <strong>TEC</strong>2647Z-2+PIR Zone <strong>Control</strong>lers . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42PIR Occupancy Sensor Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42PIR Occupancy Sensor Logic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<strong>TEC</strong>2664Z-2 Rooftop <strong>Control</strong>ler . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43<strong>TEC</strong>2664Z-2 Rooftop <strong>Control</strong>ler Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Main User Menu Access Modifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Sequence of Auto Status Display Scrolling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 502<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!