Table 2: <strong>TEC</strong>2647Z-2 <strong>and</strong> <strong>TEC</strong>2647Z-2+PIR Zone <strong>Control</strong>ler InstallerConfiguration Menu (Part 5 of 7)ParameterAppearingon DisplayDescription <strong>and</strong> Default Selection OptionsUnocc HTUnocc CLSt-By HT 3St-By CL 3Set TypeSets the Unoccupied Heatingsetpoint value.Default: 62.0°F/16.5°CSets the Unoccupied Coolingsetpoint value.Default: 80.0°F/26.5°CSets the <strong>St<strong>and</strong></strong>by Heating setpointvalue.The value of this parameter shouldreside between the occupied <strong>and</strong>unoccupied heating setpoints, <strong>and</strong>ensure that the difference betweenthe st<strong>and</strong>by <strong>and</strong> the occupiedvalues can be recovered in a timelymanner when motion is detected inthe zone.Default: 65.0°F/18.5°CNote: This setpoint is used whenan occupancy sensor isconnected <strong>and</strong> configuredon BI1, or when a PIRoccupancy sensor cover isused.Sets the <strong>St<strong>and</strong></strong>by Cooling setpointvalue.The value of this parameter shouldreside between the occupied <strong>and</strong>unoccupied cooling setpoints.Ensure that the difference betweenthe st<strong>and</strong>by <strong>and</strong> the occupiedvalues can be recovered in a timelymanner when motion is detected inthe zone.Default: 75.0°F/24.0°CNote: This setpoint is used whenan occupancy sensor isconnected <strong>and</strong> configuredon BI1, or when a PIRoccupancy sensor cover isused.Provides the option of temporarilychanging the heating or coolingsetpoint by pressing the UP/DOWNarrow keys.Default: permnentRange: 40.0°F/4.5°C to90.0°F/32.0°CRange: 54.0°F/12.0°C to100.0°F/37.5°CRange: 40.0°F/4.5°C to90.0°F/32.0°CRange: 54.0°F/12.0°C to100.0°F/37.5°CNote: When adjusting thetemperature, press theUP/DOWN arrow keys tochange the temperature in0.5F°/0.5C° increments;press <strong>and</strong> hold theUP/DOWN arrow keys tochange the temperature in5.0F°/5.0C° increments.(temporar): Local changes to the heating or cooling setpoints aretemporary <strong>and</strong> remain effective <strong>for</strong> the specified TOccTime.(permnent): Local changes to the heating or cooling setpoints arepermanently stored in the zone controller memory.<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!