12.07.2015 Views

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

TEC Zoning Control System for Stand-Alone and BACnet® MS/TP ...

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The OVERRIDE key also allows access to the Installer Configuration Menu.See Configuring the <strong>TEC</strong>2647Z-2 or <strong>TEC</strong>2647Z-2+PIR Zone <strong>Control</strong>ler onpage 15.• UP/DOWN arrow keys change the configuration parameters <strong>and</strong> activate asetpoint adjustment.Backlit LCDThe zone controller includes a two-line, eight-character backlit display. Low-levelbacklighting is present during normal operation <strong>and</strong> brightens when any userinterface key is pressed. The backlight returns to low level when the zonecontroller is left unattended <strong>for</strong> 45 seconds.Light-Emitting Diodes (LEDs)Two LEDs are included to show a call <strong>for</strong> heating or a call <strong>for</strong> cooling:• The HEAT LED is on when heating or reheat is on.• The COOL LED is on when cooling is on.Passive Infrared (PIR) Onboard Occupancy Sensor (<strong>TEC</strong>2647Z-2+PIR Model)The PIR onboard occupancy sensor allows <strong>for</strong> automatic switching between fullyadjustable occupied <strong>and</strong> st<strong>and</strong>by temperature setpoints without user interaction.This feature results in incremental energy savings during scheduled occupiedperiods when the space is unoccupied.Status Display MenuThe Status Display Menu appears during normal zone controller operation. Thismenu continuously scrolls through the following parameters:• Room Temperature• Occupancy Status(Occupied/Unoccupied/<strong>St<strong>and</strong></strong>by/Override)• Outside Temperature (Installation of an outside air temperature sensor allowsthe H lock <strong>and</strong> C lock parameters of the rooftop controller to discontinueheating or cooling operation in response to the outside air temperature. If anoutside air temperature sensor is not installed, an ambiguous outside airtemperature displays on the zone controller unless its MenuScro parameter isset to off.)Note: An option is available within the Installer Configuration Menu to lock outthe scrolling display <strong>and</strong> show only the Room Temperature parameter.PIR Onboard Occupancy Sensor Operation (<strong>TEC</strong>2647Z-2+PIR Model)The zone controller provides advanced occupancy logic when equipped with aPIR occupancy sensor cover or a remote PIR occupancy sensor attached to BI1.Note: Set the PIR Func parameter to on as described in Table 2 to enable thePIR occupancy sensing function.12<strong>TEC</strong> <strong>Zoning</strong> <strong>Control</strong> <strong>System</strong> <strong>for</strong> <strong>St<strong>and</strong></strong>-<strong>Alone</strong> <strong>and</strong> <strong>BACnet®</strong> <strong>MS</strong>/<strong>TP</strong> Networked ApplicationsTechnical Bulletin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!