CHAPTER 11.TESTSThe random vibrations are per<strong>for</strong>med with <strong>the</strong> intensity indicated in figure11.2: it has to be applied along each of three axis.Figure 11.2: Qualification level <strong>for</strong> random vibrationsThe test duration is 4 minutes.The shock test, and its equivalent sinus test, is per<strong>for</strong>med with <strong>the</strong> ShockResponse Spectrum (SRS) shown in figure 11.3 at severity level 2 <strong>for</strong> <strong>the</strong> amplificationfactor Q=10, corresponding to a damping ξ = 0.05. It has to beexecuted three times along each of three axis.Figure 11.3: Shock Response Spectrum <strong>for</strong> Q=10.qualification is <strong>the</strong> severity level 2The level prescripted <strong>for</strong>Galli Stefania 109 University of Liège