15.14. Print a Calibration ReportAfter you calibrate the unit, print a calibration report and keep it as proof of timely calibrationand as a reference, should any equipment need repair in the future.The calibration report contains the Calibration K constants. If the calibration file becomescorrupted, refer to the report and re-enter the Calibration K values on the Calibration dialogbox. This will save having to recalibrate the BCT.To print the calibration report, open the Calibration dialog box and click Print.15.15. Disconnect EquipmentObserve electrical safety precautions when disconnecting cables and replacing the BCTcover. High voltages may be present.1. Close the BCT-2000 software.2. Power off the BCT and the CS-2000.3. Disconnect the Cell cable and the System cable from the CS-2000 and BCT.4. Replace the BCT-128 or BCT-256 cover if required.15.16. Calibration BackupDuring the calibration process, calibration data is saved to the bct2000setup.mdb file underprogramfiles\alber\bct2000\setup. It is strongly recommended that you back up this data fileto a 3.5-inch disk, to save having to recalibrate the system if the BCT software must be reinstalled.Refer to Software Installation and Backup.70

16. MaintenanceThe BCT-2000 Series test system should provide years of service if properly maintained. Cleanthe laptop computer screen and case using a soft cloth, slightly moistened with water. Do not usecommercial or industrial cleaners that may attack the computer display and housing. Neverexpose the computer or the BCT-128 or BCT-256 to water, high humidity, or dampness.WARNING: Before cleaning any component, ensure the system is disconnected and power to theunit has been shut offSense Leads - Clean the BCT-2000 sense leads after each use. The acid to which the sense leadclips are exposed during testing should be neutralized often, using a water and baking sodamixture. Brush this mixture onto the sense lead clip, then rinse well with clean, cool tap water.When cleaning the sense lead clips with any water or water based solution, ensure the system isdisconnected and power to the unit has been shut off. Dry with a clean, soft cloth.The BCT-2000 is microprocessor based and has no user-replaceable components. Also, becausehigh voltage exists in several areas in each unit, only knowledgeable users should remove thecovers or cowling from devices when required. Failure to comply with this restriction could voidthe system warranty.WARNING: High voltages exist inside the BCT-2000 system components and on the CS-2000terminals. Calibration must be performed only by technically qualified persons. Observeelectrical safety precautions when removing and installing the BCT cover, and when connectingleads and making adjustments.The shipping cases will protect the BCT-2000 from normal bumps and bangs when storedproperly, and will provide protection during shipment between test sites.71

15.14. Print a Calibration ReportAfter you calibrate the unit, print a calibration report <strong>and</strong> keep it as proof of timely calibration<strong>and</strong> as a reference, should any equipment need repair in the future.The calibration report contains the Calibration K constants. If the calibration file becomescorrupted, refer to the report <strong>and</strong> re-enter the Calibration K values on the Calibration dialogbox. This will save having to recalibrate the <strong>BCT</strong>.To print the calibration report, open the Calibration dialog box <strong>and</strong> click Print.15.15. Disconnect EquipmentObserve electrical safety precautions when disconnecting cables <strong>and</strong> replacing the <strong>BCT</strong>cover. High voltages may be present.1. Close the <strong>BCT</strong>-<strong>2000</strong> software.2. Power off the <strong>BCT</strong> <strong>and</strong> the CS-<strong>2000</strong>.3. Disconnect the Cell cable <strong>and</strong> the System cable from the CS-<strong>2000</strong> <strong>and</strong> <strong>BCT</strong>.4. Replace the <strong>BCT</strong>-<strong>128</strong> or <strong>BCT</strong>-<strong>256</strong> cover if required.15.16. Calibration BackupDuring the calibration process, calibration data is saved to the bct<strong>2000</strong>setup.mdb file underprogramfiles\alber\bct<strong>2000</strong>\setup. It is strongly recommended that you back up this data fileto a 3.5-inch disk, to save having to recalibrate the system if the <strong>BCT</strong> software must be reinstalled.Refer to <strong>Software</strong> Installation <strong>and</strong> Backup.70

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!