12.07.2015 Views

BCT-2000 Software and BCT-128 and BCT-256 User's Guide - Alber

BCT-2000 Software and BCT-128 and BCT-256 User's Guide - Alber

BCT-2000 Software and BCT-128 and BCT-256 User's Guide - Alber

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

15.4. Cell As-Found1. Complete the Cell – Before Calibration section of the Calibration Record as follows:2. On the main menu, click Calibration to open the Calibration dialog box.3. Set the DMM to volts.4. Connect the DMM to the CS-<strong>2000</strong> Cell 1 banana jacks.5. Set the CS-<strong>2000</strong> Cell 1 switch to +12V.6. Observe the DMM voltage reading. Record the voltage on the Calibration Record underDMM Input.7. In the Present Readings area of the Calibration dialog box, observe the value in the Cell 1box. Record the value under Cell – As-Found.8. Set the CS-<strong>2000</strong> Cell 1 switch to +2V.9. Observe the DMM voltage reading. Record the voltage under DMM Input.10. Observe the value in the Cell 1 box. Record the value under Cell – As-Found.11. Remove the DMM from the CS-<strong>2000</strong>.15.5. Overall Current As-Found1. Complete the Overall Current – Before Calibration section of the Calibration Record asfollows:2. Set the DMM to millivolts.3. Connect the DMM to the CS-<strong>2000</strong> 0 – 200mV jacks.4. Set the CS-<strong>2000</strong> Reverse Polarity switch to plus (+).5. Adjust the CS-<strong>2000</strong> for a DMM reading of 50mV. Record the voltage on the CalibrationRecord under DMM Input.6. In the Present Readings area, observe the value in the Amps box. Record the value underOverall Current – As-Found.7. Adjust the CS-<strong>2000</strong> for a DMM reading of 100mV. Record the voltage under DMMInput.8. Observe the value in the Amps box. Record the value under Overall Current – As-Found.9. Adjust the CS-<strong>2000</strong> for a DMM reading of 150mV. Record the voltage under DMMInput.10. Observe the value in the Amps box. Record the value under Overall Current – As-Found.11. Set the CS-<strong>2000</strong> Reverse Polarity switch to minus (-).12. Repeat steps 5 to 10 for negative inputs of 50mV, 100mV, <strong>and</strong> 150mV.NOTE: The <strong>BCT</strong>-<strong>2000</strong> only displays positive numbers, even though the input is negative.13. Remove the DMM from the CS-<strong>2000</strong>.62

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!