11.8. ContactOn the Setup menu, click Contact to display the Contact dialog box.Figure 16. Setup - ContactThe Contact dialog box is an information screen and has no effect on tests. Type the names ofpersons responsible for the system at the site and for service, and their telephone numbers ande-mail addresses.11.9. Voltage PolarityThe BCT-2000 systems features automatic polarity sensing, and no user input is required.The system senses when Cell 1 is the most positive or the most negative cell in the string.30
12. Running the TestAt this point, the BCT-2000 must be connected as described in Connecting the System and themain menu displayed. On the main menu, click Test. The BCT Test screen displays all relevantinformation for monitoring test progress and parameters in a real time mode.OV, Amps, KW, and Capacity - The top of the screen indicates battery OV (overall voltage),load in amps, power in kilowatts, and the present capacity of the battery. (The capacity iscalculated only during a Performance or Modified Performance test.)Intertier - The Intertier area displays the voltage of each intertier. Single click on a bar to displaythe value of an intertier. Double-click the graph to increase it to full screen. In this mode, thegraph does not update. To return to normal view, press ESC.Figure 17. BCT TestNudge - Next to the Amps value are arrows that slightly increase or decrease (nudge) the loadwithin target when in the auto mode. When controlling the load, the BCT is considered on targetwhen the target current plus 1.5% of target current plus 1.5 amps is achieved. For example, on aload of 500 amps, the BCT-2000 could set the load at 500 amps plus 1.5% (7.5 amps) plus 1.5amps, or as high as 509 amps. The Nudge control lets you change the load to move the currentcloser to 500 amps.Duration and Test Time - Individual cells or modules are displayed in a bar graph format.Presently active step duration and target value, in amps or watts, are in the lower left of thescreen. The Test Time area displays the present step total test times.31
- Page 5 and 6: 1. Warranty and Limitation of Liabi
- Page 9 and 10: Table of Contents1. WHAT'S NEW ....
- Page 11: 15.8. Preamp Offset and Gain As-Fou
- Page 14 and 15: The manual has more screen shots. I
- Page 16 and 17: 3. System RequirementsThe following
- Page 18 and 19: 5. PasswordWhen you select certain
- Page 20 and 21: 7. BCT-2000 Initial TestBefore conn
- Page 22 and 23: 8. Main MenuThe main menu is where
- Page 24 and 25: 9. Recommended TestsPrior to perfor
- Page 26 and 27: 10. Connecting the SystemAfter perf
- Page 28 and 29: 17. Connect the leads labeled IT-1(
- Page 30 and 31: Add Site / Delete Site - To add a s
- Page 32 and 33: 11.4.1. Performance TestAlso known
- Page 34 and 35: 11.4.4. Rundown TestA rundown test
- Page 36 and 37: 11.5.3. Temperature and CorrectionA
- Page 38 and 39: 11.5.7. Calculate Capacity at Targe
- Page 40 and 41: 11.7. Load BankOn the Setup menu, c
- Page 44 and 45: Test Leads and Voltages - Click a b
- Page 46 and 47: 20, 10, 5, 1 and All Off - You may
- Page 48 and 49: 12.5. Test Screen ToolbarThe Toolba
- Page 50 and 51: Figure 26. Test Steps - Constant Po
- Page 52 and 53: 12.6. Charger Test ScreenWhen the C
- Page 54 and 55: The Files of Type drop-down list le
- Page 56 and 57: 13.5. Criteria ScreenClick the Crit
- Page 58 and 59: Ignore Zero Target Steps in Capacit
- Page 60 and 61: 13.9. Filter ScreenClick the Filter
- Page 62 and 63: Change - Use the Properties dialog
- Page 64 and 65: 13.17. Opening an Archive FileLoad
- Page 66 and 67: 14. Running DiagnosticsThe DAM (Dat
- Page 68 and 69: 14.3. Load Bank DiagnosticLoad bank
- Page 70 and 71: Figure 50. Load Bank AnalysisThe Lo
- Page 72 and 73: 15. System CalibrationThis section
- Page 74 and 75: 15.4. Cell As-Found1. Complete the
- Page 76 and 77: 15.8. Preamp Offset and Gain As-Fou
- Page 78 and 79: 15.10. Cell Calibration1. Calibrate
- Page 80 and 81: 15.12. Overall Battery Calibration1
- Page 82 and 83: 15.14. Print a Calibration ReportAf
- Page 84 and 85: 17. Upgrading BCT-2000 SoftwareUpgr
- Page 86 and 87: 3. Select F2 Load Control Diagnosti
- Page 88 and 89: OVERALLBATTERYBefore CalibrationAft
- Page 90 and 91: 19. Run Time Error MessagesRun Time
12. Running the TestAt this point, the <strong>BCT</strong>-<strong>2000</strong> must be connected as described in Connecting the System <strong>and</strong> themain menu displayed. On the main menu, click Test. The <strong>BCT</strong> Test screen displays all relevantinformation for monitoring test progress <strong>and</strong> parameters in a real time mode.OV, Amps, KW, <strong>and</strong> Capacity - The top of the screen indicates battery OV (overall voltage),load in amps, power in kilowatts, <strong>and</strong> the present capacity of the battery. (The capacity iscalculated only during a Performance or Modified Performance test.)Intertier - The Intertier area displays the voltage of each intertier. Single click on a bar to displaythe value of an intertier. Double-click the graph to increase it to full screen. In this mode, thegraph does not update. To return to normal view, press ESC.Figure 17. <strong>BCT</strong> TestNudge - Next to the Amps value are arrows that slightly increase or decrease (nudge) the loadwithin target when in the auto mode. When controlling the load, the <strong>BCT</strong> is considered on targetwhen the target current plus 1.5% of target current plus 1.5 amps is achieved. For example, on aload of 500 amps, the <strong>BCT</strong>-<strong>2000</strong> could set the load at 500 amps plus 1.5% (7.5 amps) plus 1.5amps, or as high as 509 amps. The Nudge control lets you change the load to move the currentcloser to 500 amps.Duration <strong>and</strong> Test Time - Individual cells or modules are displayed in a bar graph format.Presently active step duration <strong>and</strong> target value, in amps or watts, are in the lower left of thescreen. The Test Time area displays the present step total test times.31