ANSALDO ENERGIA Power Generation Solutions

ANSALDO ENERGIA Power Generation Solutions ANSALDO ENERGIA Power Generation Solutions

ansaldoenergia.com
from ansaldoenergia.com More from this publisher
12.07.2015 Views

specific architectural requirements to ensure environmentaland landscape integration in such a way as toreduce visual and acoustic impact. The buildings areclad in panels that insulate from and absorb sound,which represent one of the main visual features of theplant, along with the big hexagonal concrete stack about100 m high and the brick red colour used for variousplant sections, recalling the natural colours of the areasurrounding the plant. So far as power generation is concerned,the plant has been designed to meet the voltageand frequency regulation requirements of the Italiantransmission network as stipulated by Terna (the ItalianNational Grid operator), while on a functional level theplant has been designed to deliver maximum operatingflexibility in accordance with legal atmospheric pollutantemission criteria. The customer can vary load on a dailybasis in peak hours and during the weekend. Rapidplant start up allows the customer to begin generatingpower quickly, as well as to operate with different plantconfigurations and variable loads, providing a rapid andflexible response to network demand.The project was given the “Notice to Proceed” by the customerin April 2008 and construction work began in February2009. A constant focus on the real needs of thecustomer and the climate of proactive collaborationestablished, together with technical expertise and carefulplanning and monitoring of work, have made it possibleto achieve the general project objectives and,specifically, plant delivery (PAC issued by customer Sorgenia)in just 30 months from the NTP. Site work (civilworks, electromechanical assembly, start-up activitiesand testing) involved up to about 850 people on site inpeak periods and was performed in such a way as to ensurethe health and safety of both its own workers, andthose of associated companies and sub-contractorsworking on site.With the final hand-over of the plant to the customer,planned for November 2010, the Long Term ServiceAgreement covering maintenance will come into effect.Under the terms of this contract Ansaldo Energia is committedfor 7+7 years to managing and performing routinemaintenance and repair work on the 2 gas turbinesets, undertaking to maintain performance values withminimum deterioration and high turbo generator availabilityvalues for the entire duration of the contract.The agreement also entails operating parameter loggingand remote monitoring 24/7 from the diagnostic controlroom at Ansaldo Energia’s Genoa production facility.

Contract: TuranoLodigianoClient: SorgeniaType of supply contract: EPC ContractCountry: ItalySite Type: GreenfieldService Agreement: LTSACommercial operation: 2010Configuration:800 MW (2+1) Multishaft CCGENGENGENGTSTGTHRSGCond.HRSGThe information contained in this publication is provided for illustrative purposesonly. Product descriptions and content may change in consideration of specific marketsituations. Ansaldo Energia may make changes to the descriptions provided atany time for technical or commercial reasons.Main characteristicsPlant main featuresTurano Lodigiano is a 2+1 combined cycle unit with aircondenser for electrical energy production. The expectedplant efficiency is over 57%. The plant minimum technicalload, thanks to the new VeLoNOx TM burners, will be aboutthe 50%. This power plant is characterized by an architectonicalcover solution for the main components and for theHRSG stack to minimize the environmental impact andpromote the plant acceptance and territorial integration.Moreover, to reduce the environmental impact, the newproprietary ZLD system has been implemented to reducethe fresh water consumption and to comply with the localregulation that prohibits any liquid effluents emission fromthe industrial sites. This system allows an industrial waterrecover of about the 98%.Gas TurbineAE94.3A x 277.2 MW - 50 HzMain fuel: natural gasSteam TurbineRT30 x 268 MW - 50 Hz123/28.5/4.9 bar - 544/549/231°CGeneratorGT units: TRY - L56 - 330 MVA - 18 kV - 50 Hz - air cooledST unit: TRX - L56 - 330 MVA - 18 kV - 50 Hz - air cooledHeat Recovery Steam GeneratorThree pressure levels with RH, natural circulation,drum type with integrated deareator.Cooling SystemAir Condenser, single row, 24 modules, double speed type.16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

Contract: TuranoLodigianoClient: SorgeniaType of supply contract: EPC ContractCountry: ItalySite Type: GreenfieldService Agreement: LTSACommercial operation: 2010Configuration:800 MW (2+1) Multishaft CCGENGENGENGTSTGTHRSGCond.HRSGThe information contained in this publication is provided for illustrative purposesonly. Product descriptions and content may change in consideration of specific marketsituations. Ansaldo Energia may make changes to the descriptions provided atany time for technical or commercial reasons.Main characteristicsPlant main featuresTurano Lodigiano is a 2+1 combined cycle unit with aircondenser for electrical energy production. The expectedplant efficiency is over 57%. The plant minimum technicalload, thanks to the new VeLoNOx TM burners, will be aboutthe 50%. This power plant is characterized by an architectonicalcover solution for the main components and for theHRSG stack to minimize the environmental impact andpromote the plant acceptance and territorial integration.Moreover, to reduce the environmental impact, the newproprietary ZLD system has been implemented to reducethe fresh water consumption and to comply with the localregulation that prohibits any liquid effluents emission fromthe industrial sites. This system allows an industrial waterrecover of about the 98%.Gas TurbineAE94.3A x 277.2 MW - 50 HzMain fuel: natural gasSteam TurbineRT30 x 268 MW - 50 Hz123/28.5/4.9 bar - 544/549/231°CGeneratorGT units: TRY - L56 - 330 MVA - 18 kV - 50 Hz - air cooledST unit: TRX - L56 - 330 MVA - 18 kV - 50 Hz - air cooledHeat Recovery Steam GeneratorThree pressure levels with RH, natural circulation,drum type with integrated deareator.Cooling SystemAir Condenser, single row, 24 modules, double speed type.16152 Genova - Via N. Lorenzi, 8 - ItalyPhone: +39 010 6551 - Fax: +39 010 655 6209www.ansaldoenergia.it

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!