dimension shall be 20 <strong>in</strong>ches. The net clear open<strong>in</strong>g dimensionsshall be the result of normal operation of the open<strong>in</strong>g.c. 1009.3 Maximum height from the floor: Emergency escape <strong>and</strong>rescue open<strong>in</strong>g shall have the bottom of the clear open<strong>in</strong>g notgreater than 44 <strong>in</strong>ches (1118 mm) measured from the floor.5. Basement Egress W<strong>in</strong>dows:a. Sill height of w<strong>in</strong>dow above floor: Not to exceed 44”M<strong>in</strong>imum open<strong>in</strong>g area: ≥ 5.7 sq. ft.M<strong>in</strong>imum open<strong>in</strong>g height ≥ 24”M<strong>in</strong>imum open<strong>in</strong>g width: ≥ 20”b. W<strong>in</strong>dow Wells/Area Wells:Required where w<strong>in</strong>dow open<strong>in</strong>g sill height is below groundelevation.Horizontal dimensions: ≥ 9 sq.ft. (width x projection)Horizontal projection: ≥ 36 “c. Ladders:Required on w<strong>in</strong>dow wells deeper than 44” <strong>and</strong> must bepermanently attached.Ladder may encroach <strong>in</strong>to well up to 6”.Step distance between rungs: ≤ 18”Rungs:12” wide or greater <strong>and</strong> must project a m<strong>in</strong>imum of 3” awayfrom wall but maximum of 6”.d. Grates:Shall be removable without special tools.6. Safety Glaz<strong>in</strong>ga. Safety Glaz<strong>in</strong>g Requirements from IBC 2003:b. 2406.3 Hazardous locations. The follow<strong>in</strong>g shall be consideredspecific hazardous locations requir<strong>in</strong>g safety glaz<strong>in</strong>g materials:c. Glaz<strong>in</strong>g <strong>in</strong> sw<strong>in</strong>g<strong>in</strong>g doors except jalousiesd. Glaz<strong>in</strong>g <strong>in</strong> fixed <strong>and</strong> slid<strong>in</strong>g panels of slid<strong>in</strong>g door assemblies <strong>and</strong>panels <strong>in</strong> slid<strong>in</strong>g <strong>and</strong> bifold closet door assemblies.e. Glaz<strong>in</strong>g <strong>in</strong> storm doors.f. Glaz<strong>in</strong>g <strong>in</strong> unframed sw<strong>in</strong>g<strong>in</strong>g doors.g. Glaz<strong>in</strong>g <strong>in</strong> doors <strong>and</strong> enclosures for hot tubs, whirlpools, saunas,steam rooms, bathtubs <strong>and</strong> showers. Glaz<strong>in</strong>g <strong>in</strong> any portion of abuild<strong>in</strong>g wall enclos<strong>in</strong>g these compartments where the bottomexposed edge of the glaz<strong>in</strong>g is less than 60 <strong>in</strong>ches above ast<strong>and</strong><strong>in</strong>g surface.h. Glaz<strong>in</strong>g <strong>in</strong> an <strong>in</strong>dividual fixed or operable panel adjacent to a doorwhere the nearest exposed edge of the glaz<strong>in</strong>g is with<strong>in</strong> a 24-<strong>in</strong>charc of either vertical edge of the door <strong>in</strong> a closed position <strong>and</strong>where the bottom exposed edge of the glaz<strong>in</strong>g is less than 60<strong>in</strong>ches above the walk<strong>in</strong>g surface.i. Exceptions:6

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!