REF. LENGTH DISTAL THREADDIAMETERPITCH DISTALTHREADDIAMETEROF THE HEADPITCHPROXIMAL THREADSCREW SHAFTDIAMETERHEXAGONALBROACHINSIDEDIAMETERME TATARSAL OSTEOTOMY (SCARF)- Easy insertion thanks to guide wire- Complete sinking of the screw headPHALANGEAL OSTEOTOMY WITH SCREWV30- Maximum inter-fragmentary compression enabling early return of weight bearingand «per primam» consolidation- Stabilization of the reduction before screw insertion- Easy insertion thanks to guide wire- Inter -fragmentary compression effect- Long distal thread ensuring maximum anchoring of the screw in the cortexV23V3010 10 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3012 12 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3014 14 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3016 16 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3018 18 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3020 20 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3022 22 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3024 24 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3026 26 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3028 28 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3030 30 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3032 32 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3034 34 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3036 36 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3038 38 mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmV3040 40mm 3 mm 1,25 mm 4,7 mm 1,05 mm 1,9 mm 2 mm 0,8 mmAll the screws here are available sterile (VS30)V2312 12 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2314 14 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2316 16 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2318 18 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2320 20 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2322 22 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2324 24 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2326 26 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmV2328 28 mm 2,3 mm 1 mm 3,4 mm 0,8 mm 1,6 mm 1,5 mm 0,8 mmAll the screws here are available sterile (VS23)WEIL T YPE CER VICO - CEPHALIC OSTEOTOMY- Direct fitting of implant thanks to the distal perforator- Non-retractable screw avoiding any conflict with extensory apparatus- Optimal fixation of the osteotomy through inter-fragmentary compressionand “per priman” consolidationPHALANGEAL OSTEOTOMY WITH MICRO NAIL-PLATE- Inter fragmentary compression and self-reduction effect (DCP)- Optimum resistance in weak bone- Easy placementV20A23V20 11 11 mm 2 mm 0,8 mm 3,2 mm 0,6 mm 1,2 mm 1,5 mm -V2012 12 mm 2 mm 0,8 mm 3,2 mm 0,6 mm 1,2 mm 1,5 mm -V2013 13 mm 2 mm 0,8 mm 3,2 mm 0,6 mm 1,2 mm 1,5 mm -V2014 14 mm 2 mm 0,8 mm 3,2 mm 0,6 mm 1,2 mm 1,5 mm -All the screws here are available sterile (VS20)BR080 Key-Wire diameter : 0,8 mm - Length : 80 mm - Simple trocar pointBR100 K-Wire diameter : 0,8 mm - Length : 100 mm - Simple trocar pointA2300 Micro nail-plate lenght : 14 mm pitch : 10 mm thickness : 0,95 mmA2311 11 mm 2,3 mm 1 mm 3,15 mm - 1,6 mm 1,5 mm 0,8 mmA2312 12 mm 2,3 mm 1 mm 3,15 mm - 1,6 mm 1,5 mm 0,8 mmA2313 13 mm 2,3 mm 1 mm 3,15 mm - 1,6 mm 1,5 mm 0,8 mmA2314 14 mm 2,3 mm 1 mm 3,15 mm - 1,6 mm 1,5 mm 0,8 mmA2315 15 mm 2,3 mm 1 mm 3,15 mm - 1,6 mm 1,5 mm 0,8 mmAll the screws here are available sterile (AS23)FP - 0101OMNITECH - rév.02 - 12/2012 - ENSmall fragmentsosteosynthesis screws- Screw head is completely sunk and blunt tipped, therefore non agressive305, Allées de Craponne13300 Salon de ProvenceFranceTel. : +33 (0)4 90 44 60 60Fax : +33 (0)4 90 44 60 61think Simplewww.biotech-<strong>ortho</strong>.com


INSTRUMENTATIONTOTAL TRACEABILITY SYSTEMMV000US Patent N° 6.802.421 - French Patent N° 98 13350Ergonomic handle with quick couplingsystem (A.O. Synthes style), for countersinking,screw drinving and nail-plate manipulation.FT301Bone holding forcepsfor metatarsal osteotomy (Scarf)Screws for metatarsalosteotomy (Scarf)A stainless steelsterilization containerwith its protected filter isalso available (Ref. CS100=TRACER SUPPORT AND OMNITECH SCREW ASSEMBLYFT 300Rotating toolswith quick couplingsystem(A.O.Synthes style)Traceability is the ability to trace the history, application or location of an entity, bymeans of recorded identifications.FR 300Disengaged from the implant during the procedure, the coded lot number which isetched on the tracer support is then easily transfered to the patient file.SB000K-Wires housing whichmay contain up to 6 wiresTV 300Depth gaugeMicro nails-platesand associated screwsfor phalangeal osteotomyScrews for Weil-typeosteotomyGripping slotsImplant to be recordedErgonomic handlewith quick coupling system(A.O. Synthese style)Bone lever for metatarsal headluxation during Weil’s osteotomyScrews for phalangeal osteotomyJA000Depth gaugeFT 230Removable K-Wires housingGuide for phalangealosteotomy withmicro nail-plateMaterial coded lotnumber of thetracer supportImplant coded lotnumber, etched on thetracer supportFR 230TV 230SMALL FRAGMENTS OSTEOSYNTHESIS SCREWSVA000TTS UTILIZATION PROTOCOLaPlace screws forceps’ jaws in the slots and remove the assembly while maintainingthe tightening.Guide for micro nail-plateand drill guide Ø 2mmTV 200Surgical correction of static forefoot disorder has benefited over the pastfew years from the development of new techniques: Scarf osteotomy ofthe first metatarsal and phalangeal osteotomy, Weil-type cervico-cephalicosteotomy, etc.bThe implant is then splitted off from the tracer support, this latter is put back in itschamber so that reference and lot number can be easily transfered to the patientfile at the end of surgical operation.SP000lBone lever for metatarsal headluxation during Weil’s osteotomyFT 150For all these procedures the quality of the osteosynthesis is a key elementtowards the lessening of post operative pain and the patient’s early returnto walking, as well as towards reliable clinical results.The <strong>Omnitech</strong>® system is grouped into a single tray and enables a simplersurgical procedure.TV 230FT 230This product must be decontaminated and sterilized by using hightemperature steam : 134°C for 18 minutes in compliance with therecommandations of WHO. The sterilization by the method is under theresponsability of the user.A 2300

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!