12.07.2015 Views

Soot Deposits and Fires in Exhaust Gas Boiler - Martin's Marine ...

Soot Deposits and Fires in Exhaust Gas Boiler - Martin's Marine ...

Soot Deposits and Fires in Exhaust Gas Boiler - Martin's Marine ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Chapter II<strong>Boiler</strong> Experience <strong>and</strong>Design CriteriaStatistical analyses of soot fires<strong>Soot</strong> fires <strong>in</strong> exhaust gas boilers werevery unusual some years ago but, dur<strong>in</strong>gthe last two decades, soot deposits<strong>and</strong> soot fires have occurred more often.Analyses of soot fires <strong>in</strong>dicate that, <strong>in</strong>most cases, they occur <strong>in</strong> connectionwith manoeuvr<strong>in</strong>g, often follow<strong>in</strong>g astay <strong>in</strong> harbour.On the basis of a sample of 82 ships,most of which are equipped with twostrokema<strong>in</strong> eng<strong>in</strong>es <strong>and</strong> water tube typeboilers, the NK “Guide to Prevention of<strong>Soot</strong> Fire on <strong>Exhaust</strong> <strong>Gas</strong> Economizers1992”, Ref. [4], presents a statisticalparameter survey of soot fires. The surveycovers 53 ships with troubles (sootfire <strong>and</strong> damage) <strong>and</strong>, for comparisonpurposes, also 29 NK ships with notroubles. The eng<strong>in</strong>es are <strong>in</strong> the powerrange of about 4,000-30,000 kW, <strong>and</strong>about 10% of the boilers are of thelarge capacity types, <strong>in</strong>clud<strong>in</strong>g dualpressure type boilers.It should be noted that ships with troubleswere extracted from a representativesample of all NK ships, while ships withno troubles were limited to cases <strong>in</strong>which NK received answers from shipyardsor boiler makers.The parameters stated below have(where known) been obta<strong>in</strong>ed from theshipyards <strong>and</strong> boiler makers <strong>in</strong> question.The parameters have been studied withregard to any dist<strong>in</strong>ct <strong>in</strong>fluence on boilertroubles <strong>and</strong>, if any such <strong>in</strong>fluence wasfound, it is <strong>in</strong>dicated <strong>in</strong> Table 1.Trouble/no trouble comparisons for someof the most <strong>in</strong>terest<strong>in</strong>g parameters havebeen made <strong>in</strong> graphical form <strong>and</strong> areshown <strong>in</strong> Figs. 17, 18, 19, 20 <strong>and</strong> 21.Even though the ships <strong>in</strong>cluded <strong>in</strong> theParameterAny dist<strong>in</strong>ct<strong>in</strong>fluence?Ship typenoMa<strong>in</strong> eng<strong>in</strong>e type no Fig. 17Ma<strong>in</strong> eng<strong>in</strong>e(s) MCR powerno<strong>Boiler</strong> sections (evaporator, preheater, etc.)noType of boiler tubes (pla<strong>in</strong>, gilled, etc.) no Fig. 18<strong>Exhaust</strong> gas <strong>in</strong>let/outlet temperatures no Fig. 19Design mean gas velocity <strong>in</strong> exhaust gas boiler yes Fig. 20Water <strong>in</strong>let velocity to boiler yes Fig. 21Circulation water flow ratio yes Fig. 21Table 1: Statistical parameter survey of soot fires <strong>in</strong> exhaust gas boilersRef.: Nippon Kaiji Kyokai, Tokyo (NK)Number of cases121086420TroubleNo troubleK L-MC K-MC RND RTA D E H L KZ L P-4L-G S-MC RD RL VMAN B&W Sulzer Mitsubishi UE MAN PielstickFig. 17: <strong>Boiler</strong> trouble – <strong>in</strong>fluence of ma<strong>in</strong> eng<strong>in</strong>e typeexam<strong>in</strong>ation have been freely selected,for which reason simple comparisonscannot be made, the results of thecomparisons may be considered as be<strong>in</strong>gvery <strong>in</strong>dicative.Ma<strong>in</strong> eng<strong>in</strong>e typesInfluence of ma<strong>in</strong> eng<strong>in</strong>e typeIt is rather <strong>in</strong>terest<strong>in</strong>g, but not surpris<strong>in</strong>g,to see that, as shown <strong>in</strong> Fig. 17, themake <strong>and</strong> type of ma<strong>in</strong> eng<strong>in</strong>e had nodist<strong>in</strong>ct <strong>in</strong>fluence on the risk of soot fire.14This document, <strong>and</strong> more, is available for download at Mart<strong>in</strong>'s Mar<strong>in</strong>e Eng<strong>in</strong>eer<strong>in</strong>g Page - www.dieselduck.net

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!