MSC 85/26/Add.2ANNEX 3Page 154EMERGENCY PROCEDURESSPECIAL EMERGENCY EQUIPMENT TO BE CARRIEDNilEMERGENCY PROCEDURESNilEMERGENCY ACTION IN THE EVENT OF FIREDo not use water. Do not use steam. Do not use CO 2 .Batten down.The specific procedures in the event of emergency provided by the shipper should beconsulted and followed, as appropriate. If in doubt, expert advice should be sought asquickly as possible.Preparations should be made for grab discharge if serious heating occurs.MEDICAL FIRST AIDRefer to the Medical First Aid Guide (MFAG), as amended.I:\MSC\85\26-Add-2.doc
MSC 85/26/Add.2ANNEX 3Page 155DIRECT REDUCED IRON (B)Lumps, pellets, cold-moulded briquettesDESCRIPTIONDirect reduced iron (DRI) (B) is a highly porous, black/grey metallic material formed by thereduction (removal of oxygen) of iron oxide at temperatures below the fusion point of iron.Cold-moulded briquettes are defined as those which have been moulded at a temperature lessthan 650 o C or which have a density of less than 5,000 kg/m 3 . Fines and small particlesunder 6.35 mm in size shall not exceed 5% by weight.CHARACTERISTICSANGLE OF REPOSE BULK DENSITY (kg/m 3 ) STOWAGE FACTOR (m 3 /t)Not applicable 1750 to 2000 0.5 to 0.57SIZE CLASS GROUPLumps and pellets:Average particle size 6.35 mmto 25 mm.Cold-moulded briquettes:Approximate maximumdimensions 35 mm to 40 mm.Fines and small particles under6.35 mm up to 5% by weight.MHBBHAZARDTemporary increase in temperature of about 30 o C due to self-heating may be expected aftermaterial handling in bulk.There is a risk of overheating, fire and explosion during transport. This cargo reacts with air andwith fresh water or seawater to produce heat and hydrogen. Hydrogen is a flammable gas thatcan form an explosive mixture when mixed with air in concentrations above 4% by volume. Thereactivity of this cargo depends upon the origin of the ore, the process and temperature ofreduction, and the subsequent ageing procedures. Cargo heating may generate very hightemperatures that are sufficient to ignite the cargo. Build-up of fines may also lead toself-heating, auto-ignition and explosion. Oxygen in cargo spaces and enclosed spaces may bedepleted.STOWAGE & SEGREGATION“Separated from” goods of classes 1 (division 1.4S), 2, 3, 4 and 5, and class 8 acids in packagedform (See IMDG Code).“Separated from” solid bulk materials of classes 4 and 5.Goods of class 1, other than division 1.4S, shall not be carried in the same ship.Boundaries of compartments where this cargo is carried shall be resistant to fire and passage ofliquid.I:\MSC\85\26-Add-2.doc
- Page 104 and 105: MSC 85/26/Add.2ANNEX 3Page 104.4 th
- Page 106 and 107: MSC 85/26/Add.2ANNEX 3Page 1062.2.3
- Page 108 and 109: MSC 85/26/Add.2ANNEX 3Page 108DISCH
- Page 110 and 111: MSC 85/26/Add.2ANNEX 3Page 110CARBO
- Page 112 and 113: MSC 85/26/Add.2ANNEX 3Page 112CARRI
- Page 114 and 115: MSC 85/26/Add.2ANNEX 3Page 114VENTI
- Page 116 and 117: MSC 85/26/Add.2ANNEX 3Page 116CARRI
- Page 118 and 119: MSC 85/26/Add.2ANNEX 3Page 118CHARC
- Page 120 and 121: MSC 85/26/Add.2ANNEX 3Page 120CHOPP
- Page 122 and 123: MSC 85/26/Add.2ANNEX 3Page 122CHROM
- Page 124 and 125: MSC 85/26/Add.2ANNEX 3Page 124CLAYD
- Page 126 and 127: MSC 85/26/Add.2ANNEX 3Page 126LOADI
- Page 128 and 129: MSC 85/26/Add.2ANNEX 3Page 1282.2 A
- Page 130 and 131: MSC 85/26/Add.2ANNEX 3Page 130.2 Pe
- Page 132 and 133: MSC 85/26/Add.2ANNEX 3Page 1322.2 S
- Page 134 and 135: MSC 85/26/Add.2ANNEX 3Page 1342.7.1
- Page 136 and 137: MSC 85/26/Add.2ANNEX 3Page 136PRECA
- Page 138 and 139: MSC 85/26/Add.2ANNEX 3Page 138CARRI
- Page 140 and 141: MSC 85/26/Add.2ANNEX 3Page 140COKE
- Page 142 and 143: MSC 85/26/Add.2ANNEX 3Page 142COLEM
- Page 144 and 145: MSC 85/26/Add.2ANNEX 3Page 144COPPE
- Page 146 and 147: MSC 85/26/Add.2ANNEX 3Page 146VENTI
- Page 148 and 149: MSC 85/26/Add.2ANNEX 3Page 148DIAMM
- Page 150 and 151: MSC 85/26/Add.2ANNEX 3Page 150DIREC
- Page 152 and 153: MSC 85/26/Add.2ANNEX 3Page 152Appro
- Page 156 and 157: MSC 85/26/Add.2ANNEX 3Page 156HOLD
- Page 158 and 159: MSC 85/26/Add.2ANNEX 3Page 158The s
- Page 160 and 161: MSC 85/26/Add.2ANNEX 3Page 160EMERG
- Page 162 and 163: MSC 85/26/Add.2ANNEX 3Page 162WEATH
- Page 164 and 165: MSC 85/26/Add.2ANNEX 3Page 164Any c
- Page 166 and 167: MSC 85/26/Add.2ANNEX 3Page 166EMERG
- Page 168 and 169: MSC 85/26/Add.2ANNEX 3Page 168FELSP
- Page 170 and 171: MSC 85/26/Add.2ANNEX 3Page 170FERRO
- Page 172 and 173: MSC 85/26/Add.2ANNEX 3Page 172FERRO
- Page 174 and 175: MSC 85/26/Add.2ANNEX 3Page 174CARRI
- Page 176 and 177: MSC 85/26/Add.2ANNEX 3Page 176VENTI
- Page 178 and 179: MSC 85/26/Add.2ANNEX 3Page 178(vi)
- Page 180 and 181: MSC 85/26/Add.2ANNEX 3Page 180venti
- Page 182 and 183: MSC 85/26/Add.2ANNEX 3Page 182(v) P
- Page 184 and 185: MSC 85/26/Add.2ANNEX 3Page 184space
- Page 186 and 187: MSC 85/26/Add.2ANNEX 3Page 186FISH
- Page 188 and 189: MSC 85/26/Add.2ANNEX 3Page 188PRECA
- Page 190 and 191: MSC 85/26/Add.2ANNEX 3Page 190FLUOR
- Page 192 and 193: MSC 85/26/Add.2ANNEX 3Page 192FLY A
- Page 194 and 195: MSC 85/26/Add.2ANNEX 3Page 194GRANU
- Page 196 and 197: MSC 85/26/Add.2ANNEX 3Page 196GYPSU
- Page 198 and 199: MSC 85/26/Add.2ANNEX 3Page 198PRECA
- Page 200 and 201: MSC 85/26/Add.2ANNEX 3Page 200CARRI
- Page 202 and 203: MSC 85/26/Add.2ANNEX 3Page 202CARRI
<strong>MSC</strong> <strong>85</strong>/<strong>26</strong>/<strong>Add.2</strong><strong>ANNEX</strong> 3Page 154EMERGENCY PROCEDURESSPECIAL EMERGENCY EQUIPMENT TO BE CARRIEDNilEMERGENCY PROCEDURESNilEMERGENCY ACTION IN THE EVENT OF FIREDo not use water. Do not use steam. Do not use CO 2 .Batten down.The specific procedures in the event of emergency provided by the shipper should beconsulted and followed, as appropriate. If in doubt, expert advice should be sought asquickly as possible.Preparations should be made for grab discharge if serious heating occurs.MEDICAL FIRST AIDRefer to the Medical First Aid Guide (MFAG), as amended.I:\<strong>MSC</strong>\<strong>85</strong>\<strong>26</strong>-Add-2.doc