12.07.2015 Views

Three analytical methods for determination of Epinastine ...

Three analytical methods for determination of Epinastine ...

Three analytical methods for determination of Epinastine ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Ramzia I. El-Bagary et al J. Chem. Pharm. Res., 2012, 4(2):1361-1369______________________________________________________________________________For the <strong>determination</strong> <strong>of</strong> the optimum UV detector wavelength, variable wavelength values were set <strong>for</strong> detection <strong>of</strong>the eluted drug and its internal standard. The optimum wavelength with ideal sensitivity and low noise was found tobe 262 nm .An accurate aliquot (0.2 ml) <strong>of</strong> EPH standard stock solution was transferred into a 10 ml volumetric flask followedby 0.1 ml <strong>of</strong> methylparaben standard tock solution then the volume was completed with methanol. When 20 µlaliquot <strong>of</strong> this mixture solution was subjected to the previously mentioned chromatographic conditions, a typicalchromatogram <strong>of</strong> both compounds in Fig (4) showing well resolved peaks <strong>of</strong> EPH at 4.004 min and its internalstandard at 5.309 min. The total run time <strong>for</strong> a complete quantification <strong>of</strong> the drug and its internal standard wasabout 6.5 min.Fig.(4): HPLC chromatogram <strong>of</strong> EPH (20 µg.ml -1 ) and methyl paraben (1 µg.ml -1 )3.4.Method validation :The proposed <strong>methods</strong> <strong>of</strong> analysis were validated as per the recommendations <strong>of</strong> ICH (IQ1,IQ2)[14] <strong>for</strong> theparameters like accuracy, linearity, precision, specificity, detection limit and quantitation limit. The regressionanalysis <strong>for</strong> the three proposed <strong>methods</strong> using the method <strong>of</strong> least squares was applied <strong>for</strong> the slope (a) and theintercept (b) where results are summarized in Table (2).Table (2): Method validation and <strong>analytical</strong> parameters obtained by the proposed <strong>methods</strong>Parameters Difference method Colorimetric method HPLC methodLinearity range (µg.ml -1 ) 16-96 20-220 20-100Regression equation *:Intercept (a)Slope (b)Y=0.0096X-0.0191 Eq.(1)-0.01910.0096Y=0.0046X+0.0257 Eq.(2)+0.0257.0.0046Y=0.0249X-0.0221 Eq.(3)-0.0221.0.0249Limit <strong>of</strong> detection (LOD) 1.31 3.25 0.76Limit <strong>of</strong> quantitation(LOQ) 3.96 9.84 2.32SD <strong>of</strong> slope S b 0.000061 0.0000082 0.0000226SD <strong>of</strong> intercept S a 0.0038 0.004528 0.0576444Correlation coefficient, r 0.9994 0.9992 0.9998Confidence limit <strong>of</strong> intercept ** -0.0191±0.008103 0.0257±0.009645 0.0221±0.122782Confidence limit <strong>of</strong> slope ** 0.0096±0.0001299 0.0046±0.0000174 0.0249±0.000048* is regression equation: Y= a + bX , where Y is the measured response , X is the concentration <strong>of</strong> the drug (µg.ml -1 )**95% confidence level.3.4.1.Linearity and Range:Linearity was established by per<strong>for</strong>ming the proposed <strong>methods</strong> using a minimum <strong>of</strong> six concentrations on threedifferent days. Linear relationships were observed over the concentration ranges <strong>of</strong> EPH stated in Table (2).3.4.2. Accuracy & Precision:Accuracy <strong>of</strong> the <strong>methods</strong> was determined by per<strong>for</strong>ming recovery studies via the standard addition technique inwhich pre-analyzed samples were taken and known quantities <strong>of</strong> standard EPH were added. Results are shown inTable (3).Interday & Intraday precisions were per<strong>for</strong>med at three concentrations levels (32, 64, 96 µg.ml -1 ) <strong>for</strong> differencemethod, (40,100,160 µg.ml -1 )<strong>for</strong> colorimetric method and (30,50,70 µg.ml -1 ) <strong>for</strong> HPLC analysis. The <strong>determination</strong>s1366

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!