Table 2 — Main Base Board Inputs and OutputsDESCRIPTION INPUT/OUTPUT I/O TYPE* <strong>Controls</strong> discharge and liquid line isolation soleniods for 30RB120-190 brine units only.SCROLLING MARQUEEPOINT NAMEPower (24 vac supply) — — —Local Equipment Network — — —<strong>Carrier</strong> Comfort Network ®(CCN)— — —CONNECTION POINTPin NotationMBB-J1, MBB-J1A,MBB-J1B11 24 vac12 GroundMBB-J9A, MBB-J9B,MBB-J9C, MBB-J9D+G-MBB-J12+G-External ChilledWater Pump InterlockPMPI Switch INPUTS→GEN.I→LOCK MBB-J4-CH15AChilled Water Flow Switch CWFS Switch INPUTS→GEN.I→LOCKMBB-J5A-CH15B15BDemand Limit Switch #1 Demand Limit SW1 Switch INPUTS→GEN.I→DLS1 MBB-J4-CH13Circuit A DischargePressure TransducerCircuit B DischargePressure TransducerDPTADPTBPressure Transducer(0-5 VDC)Pressure Transducer(0-5 VDC)PRESSURE→PRC.A→DP.APRESSURE→PRC.B→DP.BMBB-J7A-CH65V 5 vdc Ref.S SignalR ReturnMBB-J7C-CH85V 5 vdc Ref.S SignalR ReturnDual ChillerLWT ThermistorDUAL 5k Thermistor TEMPERATURE→UNIT→CHWS MBB-J6-CH3Dual Set Point Input Dual Set Point Switch INPUTS→GEN.I→DUAL MBB-J4-CH12Entering Water Thermistor EWT 5k Thermistor TEMPERATURE→UNIT→EWT MBB-J6-CH2Leaving Water Thermistor LWT 5k Thermistor TEMPERATURE→UNIT→LWT MBB-J6-CH1Outdoor Air Thermistor OAT 5k Thermistor TEMPERATURE→UNIT→OAT MBB-J6-CH4MBB-J5C-CH18Pump #1 InterlockPMP1Pump #2 InterlockPMP2SwitchINPUTS→GEN.I→PUMP 18CReverse Rotation Board Reverse Rotation Board Switch INPUTS→GEN.I→ELECMBB-J5A-CH16B16BCircuit A SuctionPressure TransducerCircuit B SuctionPressure TransducerSPTASPTBPressure Transducer(0-5 VDC)Pressure Transducer(0-5 VDC)PRESSURE→PRC.A→SP.APRESSURE→PR.B→SP.BMBB-J7B-CH75V 5 vdc Ref.S SignalR ReturnMBB-J7D-CH95V 5 vdc Ref.S SignalR ReturnUnit Status Remote Contact-Off-Enable Switch INPUTS→GEN.I→ONOF MBB-J4-CH11Alarm Relay ALM R Relay OUTPUTS→GEN.O→ALRM MBB-J3-CH24Alert Relay ALT R Relay OUTPUTS→GEN.O→ALRT MBB-J3-CH25Cooler Heater CL-HT TRIAC OUTPUTS→GEN.O→CO.HT MBB-J2B-CH21Circuit A MinimumLoad Control*MLV-A TRIAC OUTPUTS→CIR.A→HGB.A MBB-J2C-CH22Circuit B MinimumLoad Control*MLV-B TRIAC OUTPUTS→CIR.B→HGB.B MBB-J2C-CH23Pump #1 <strong>Start</strong>er PMP1 TRIAC OUTPUTS→GEN.O→PMP.1 MBB-J2A-CH19Pump #2 <strong>Start</strong>er PMP2 TRIAC OUTPUTS→GEN.O→PMP.2 MBB-J2A-CH20Ready Relay RDY R Relay OUTPUTS→GEN.O→REDY MBB-J3-CH264

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!