Table 6 — Fan Board 1 (AUX1, AUX2) Outputs*DESCRIPTION INPUT/OUTPUT I/O TYPESCROLLING MARQUEEPOINT NAMEPower (24 vac supply) — — —Local Equipment Network — — —Circuit A Low Ambient TemperatureHead Pressure Control Speed SignalCircuit B Low Ambient TemperatureHead Pressure Control Speed Signal(sizes 060-150, 210-250)Outdoor Fan Motor 1 OFM1 TRIACOutdoor Fan Motor 2 OFM2 TRIACOutdoor Fan Motor 3 OFM3 TRIACOutdoor Fan Motor 4 OFM4 TRIACOutdoor Fan Motor 5 OFM5 TRIACOutdoor Fan Motor 6 OFM6 TRIACOutdoor Fan Motor 7 OFM7 TRIACOutdoor Fan Motor 8 OFM8 TRIACMM-A† 0-10 VDC OUTPUTS→CIR.A→SPD.AMM-B† 0-10 VDC OUTPUTS→CIR.B→SPD.B*Fan boards 1 and 2 will use the AUX1 board when the low ambient temperature head pressure control option is installed.†Supplied on AUX1 board onlyNOTE: Fan Board 1 is used on 30RB060-390.CONNECTION POINTPin NotationFB1-J111 24 vac12 GroundFB1-J9+G-+G-FB1-CH9+-FB1-CH10+-FB1-J2-CH1(sizes 060-110)FB1-J2-CH2(sizes 120-150, 210-250)FB1-J2-CH3(sizes 160-190, 275, 300,315,390)FB1-J2-CH2(sizes 060-110)FB1-J2-CH3(sizes 120-150, 210-250)FB1-J2-CH4(sizes 160-190, 275, 300,315-390)FB1-J2-CH3(sizes 060, 070,090-110)FB1-J3-CH5(size 080)FB1-J2-CH1(sizes 120-150, 210-250)FB1-J2-CH2(sizes 160-190, 275, 300,315-390)FB1-J3-CH5(sizes 060, 070)FB1-J3-CH6(size 080)FB1-J3-CH7(sizes 090-110)FB1-J2-CH4(sizes 130, 150, 210-250)FB1-J3-CH6(sizes 160-190, 275-300,315-390)FB1-J3-CH5(sizes 090-110)FB1-J3-CH6(sizes 120-150, 210-250)FB1-J2-CH1(sizes 160-190, 275-300,315-390)FB1-J3-CH6(sizes 090-110, 160-190,275-300, 315-390)FB1-J3-CH7(sizes 120-150, 210-250)FB1-J3-CH5(sizes 120-150, 210-250)FB1-J3-CH8(sizes 120-150, 210-250)10
Table 7 — Fan Board 2 (AUX1, AUX2) Outputs*DESCRIPTION INPUT/OUTPUT I/O TYPESCROLLING MARQUEEPOINT NAMEPower (24 vac supply) — — —Local Equipment Network — — —Circuit B Low Ambient TemperatureHead Pressure ControlSpeed Signal(sizes 160-190, 275-300, 315-400)Outdoor Fan Motor 7 OFM7† TRIACOutdoor Fan Motor 8 OFM8 TRIACOutdoor Fan Motor 9 OFM9 TRIACOutdoor Fan Motor 10 OFM10 TRIACOutdoor Fan Motor 11 OFM11 TRIACOutdoor Fan Motor 12 OFM12 TRIACMM-B† 0-10 VDC OUTPUTS→CIR.B→SPD.B*Fan boards 1 and 2 will use the AUX1 board when the low ambient temperature head pressure control option is installed.†Output only on units with low ambient temperature head pressure control installed (AUX1).NOTE: Fan Board 2 used on 30RB160-190, 275-300, 315-390.CONNECTION POINTPinNotationFB2-J111 24 vac12 GroundFB2-J9+G-+G-FB2-CH9+-FB2-J2-CH2(sizes 160, 170, 315-345, 360B)FB2-J2-CH3(sizes 190, 275, 300, 360A, 390)FB2-J2-CH3(sizes 160, 170, 315-345, 360B)FB2-J2-CH4(sizes 190, 275, 300, 360A, 390)FB2-J2-CH1(sizes 160, 170, 315-345, 360B)FB2-J2-CH2(sizes 190, 275, 300, 360A, 390)FB2-J2-CH4(sizes 160, 170, 315-345, 360B)FB2-J3-CH5(sizes 190, 275, 300, 360A, 390)FB2-J2-CH1(sizes 190, 275-300, 360A, 390)FB2-J3-CH6(sizes 190, 275-300, 360A, 390)Reverse Rotation Board — The reverse rotationboard monitors the three-phase electrical system to providephase reversal, phase loss and under-voltage protection. SeeFig. 5. In addition, a 24-v time delay relay and contactor is usedto deenergize the entire control power of the chiller as part ofthe protection scheme. See Fig. 6. The reverse rotation boardhas two LEDs (light-emitting diodes) and two adjustable dialsettings. Under normal conditions, the upper LED will light upgreen. The lower LED is red and will flash (phase reversal) orturn on solid (phase loss and under-voltage) according to theconditions sensed.DIAL SETTINGS — The reverse rotation board has two dials.See Fig. 5. The upper dial should be set to match the incomingthree-phase voltage to the chiller with no compressorsrunning. This dial must be adjusted for 208/230-v chillers operatingon 208-v power supply. The dial should be adjusted to200-v minimum setting for this case. The lower dial is used fortrip delay and should be set fully counterclockwise to the minimum0.1 second setting. The time delay relay in the 24-v circuithas a delay setting as well and it should be set fully clockwiseto the maximum 1.0 second setting. See Fig. 6.PHASE REVERSAL PROTECTION — The control monitorsthe three-phase power sequence supplied at terminals L1,L2, and L3. If the control senses an incorrect phase relationship,the relay contacts (11/14) on the board will open. The relaycontacts will automatically reset when the correct phase sequenceis applied.PHASE LOSS AND UNDER-VOLTAGE PROTEC-TION — If the reverse rotation board senses that any one ofthe three phase inputs has no AC voltage or that any one phasehas dropped more than 20% below the voltage dial setting, therelay contacts (11/14) on the board will open. In addition,board relay contacts (21/24) will also open. If the contacts donot close within one second (time delay relay dial setting), the24-v control power to the chiller will be removed and all motoroutputs will be turned off. Control power will be restored automaticallywhen all three phases are present, in the correct sequenceand are within the limits of the voltage dial setting.LED STATUS<strong>Up</strong>per (green) LED on continuouslyLower (red) LED blinkingLower (red) LED on continuously<strong>Up</strong>per (green) LED offFUNCTIONRelay contacts closed (normaloperation)Relay contacts open (phase reversalhas occurred)Relay contacts open (phase lossor under-voltage has occurred)Power not present at L1, L2, L3(off)NOTE: Normal operation of the reverse rotation board (forexample, no faults are detected) results in a closed contactbeing applied to the MBB (plug J5A, channel 16B) through theclosed 11/14 relay contact.11