12.07.2015 Views

836-837 TANDEM - Romstal

836-837 TANDEM - Romstal

836-837 TANDEM - Romstal

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>836</strong>-<strong>837</strong> <strong>TANDEM</strong>MAIN FEATURES• Electric modulator of the gas outlet pressure:stepped (<strong>836</strong> <strong>TANDEM</strong>)or continuous (<strong>837</strong> <strong>TANDEM</strong>).• Two near-silent automatic shut-off valves in class B(class A on request).• Servo-controlled pressure regulator.• Pilot outlet (optional) with gas flow restrictor.• Inlet and pilot filters.• Inlet and outlet pressure test points.• Threaded gas inlet and outlet with provision forflange connection.• Connection for pressure regulator/combustionchamber compensation.DESCRIPTION2 4 31 On-off solenoid valve EV12 Gas outlet pressure modulator53 Adjustment screw for gas flow to thepilot4 Inlet pressure test point5 Outlet pressure test point10 1 66 On-off solenoid valve EV27 Pilot outlet8 Main gas outlet9 Holes (M5) for fixing flanges10 Connection for pressure regulator/combustion chamber compensation798214<strong>836</strong>-<strong>837</strong> <strong>TANDEM</strong>


CODES<strong>836</strong> <strong>TANDEM</strong>CodesAmbientEV Electric supplyEVModulator Electric supplyPressureAdj. StepPilot outlet Maximum gasTemperatureClassRegulator range opening rangeinlet pressurerange [°C][mbar](seconds][mbar]0<strong>836</strong>010 0÷60 220/240 V - 50 Hz B 230 V RAC 2-50 / No 600<strong>836</strong>011 0÷60 220V - 60 Hz B 220 V RAC 2-50 / No 600<strong>836</strong>016 0÷60 230/240 V - 50 Hz A 230 V RAC 2-50 / No 600<strong>836</strong>017 0÷60 220/240 V - 50 Hz B 240 V RAC 2-37 / No 600<strong>836</strong>018 0÷60 220/240 V - 50 Hz B 240 V RAC 2-37 / Yes 600<strong>836</strong>019 0÷60 220/240 V - 50 Hz B 230 V RAC 6-50 7-12 No 600<strong>836</strong>021 -20÷60 220/240 V - 50 Hz B 230 V RAC 6-50 7-12 Yes 60<strong>836</strong>-<strong>837</strong> <strong>TANDEM</strong>


<strong>837</strong> <strong>TANDEM</strong>CodesAmbientEV Electric supplyEVModulator Electric supplyPressureAdj. StepPilot outlet Maximum gasTemperatureClassRegulator range opening rangeinlet pressurerange [°C][mbar](seconds][mbar]0<strong>837</strong>010 0÷60 220/240 V - 50 Hz B 16 V DC 310 mA 2-18 / No 500<strong>837</strong>011 0÷60 220/240 V - 50 Hz B 16 V DC 310 mA 3-37 / No 500<strong>837</strong>013 0÷60 220/240 V - 50 Hz B 28 V DC 165 mA 3-37 / No 500<strong>837</strong>023 0÷60 220/240 V - 50 Hz B 28 V DC 165 mA 2-20 / No 500<strong>837</strong>024 0÷60 220/240 V - 50 Hz B 28 V DC 165 mA 3-37 / No 500<strong>837</strong>025 0÷60 220/240 V - 50 Hz B 28 V DC 165 mA 3-37 / Yes 500<strong>837</strong>029 0÷60 220/240 V - 50 Hz B 28 V DC 165 mA 2-20 / P 500<strong>837</strong>033 0÷60 220/240 V - 50 Hz B 28 V DC 165 mA 2-18 / No 500<strong>837</strong>034 0÷60 24 V - 50 Hz (Low Energy) B 28 V DC 165 mA 1.5-25 / No 500<strong>837</strong>035 0÷60 24 V - 50 Hz (Low Energy) B 28 V DC 165 mA 2.5-37 / No 500<strong>837</strong>038 0÷60 220/240 V - 50 Hz B 28 V DC 165 mA 3-37 / P 500<strong>837</strong>100 0÷60 120 V - 60 Hz B 16 V DC 310 mA 3-37 / No 500<strong>837</strong>301 -20÷60 220/240 V - 50 Hz B 16 V DC 310 mA 2-20 / No 500<strong>837</strong>302 -20÷60 220/240 V - 50 Hz B 16 V DC 310 mA 3-37 / No 500<strong>837</strong>303 -20÷60 220/240 V - 50 Hz B 28 V DC 165 mA 3-37 / No 500<strong>837</strong>304 -20÷60 24 V - 60 Hz (Low Energy) B 28 V DC 165 mA 2÷25 / No 500<strong>837</strong>305 -20÷60 220/240 V - 50 Hz B 16 V DC 310 mA 2-18 / No 50PPlugged (0972041)216<strong>836</strong>-<strong>837</strong> <strong>TANDEM</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!