12.07.2015 Views

SkyView System Installation Guide - Dynon Avionics

SkyView System Installation Guide - Dynon Avionics

SkyView System Installation Guide - Dynon Avionics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

5. SV-ADAHRS-20X <strong>Installation</strong> and ConfigurationThe <strong>SkyView</strong> ADAHRS module uses MEMS sensor technology to accurately measure inertial,magnetic, and air data. To ensure accuracy in its readings, it is very important that you installthe module correctly and perform the specified calibration steps. This chapter guides youthrough that process.<strong>Dynon</strong> sells a primary ADAHRS model (SV-ADAHRS-200) and a backup model (SV-ADAHRS-201).Throughout the guide, these models are collectively referred to as “SV-ADAHRS-20X.” Theprimary and backup models are identical in functionality.Read and understand the <strong>System</strong> Planning Chapter before installing the ADAHRS.If you have more than one ADAHRS in your <strong>SkyView</strong> system, all ADAHRScalibrations are applied to all ADAHRS simultaneously. In other words, yougenerally only need to go these steps once per system, provided all ADAHRS arecalibrated, installed and are connected via <strong>SkyView</strong> Network. However, if anadditional SV-ADAHRS-20X is installed and configured at a time after the originalinstallation and calibrations in this chapter have been performed, all setup andcalibration steps in this section of the <strong>SkyView</strong> <strong>Installation</strong> manual should beperformed as if the ADAHRS is being installed for the first time.Figure 22 is a high-level overview of a suggested and installation and configuration procedurefor the SV-ADAHRS-20X:Choose alocation based onLocationRequirementsSectionPrepare thelocationInstall <strong>SkyView</strong>network cablingInstall AOA/PitotprobeReferenceAccessory<strong>Installation</strong> andConfigurationChapterInstall static port(not covered inthis guide)Install pneumaticplumbingInstall OAT probeand wiringInstall ADAHRSmodule withelectrical andpneumaticconnectionsConfigure<strong>SkyView</strong> Network*ConfigureADAHRS-relatedsettings on<strong>SkyView</strong> display*Perform magneticcalibrationPerform AOAcalibration*Assumes SV-D700 or SV-D1000 is properly installed and working.Figure 22–Suggested SV-ADAHRS-20X <strong>Installation</strong> Procedure<strong>SkyView</strong> <strong>System</strong> <strong>Installation</strong> <strong>Guide</strong> - Revision O 5-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!