12.07.2015 Views

SkyView System Installation Guide - Dynon Avionics

SkyView System Installation Guide - Dynon Avionics

SkyView System Installation Guide - Dynon Avionics

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Appendix A: Maintenance and TroubleshootingOperational State of the Internal Battery Management CircuitryThe operational state of the display's internal battery management circuitry is listed here. Ifthere is an SV-BAT-320 backup battery connected to the display, you will see one of thefollowing states:CHARGING: <strong>SkyView</strong> system voltage is above 12.25V. <strong>SkyView</strong> is running on masterpower and is charging the SV-BAT-320.DISCHARGING: <strong>SkyView</strong> system voltage is below 10V. <strong>SkyView</strong> runs on the SV-BAT-320.The SV-BAT-320 discharges.CHARGED: <strong>SkyView</strong> system voltage is above 12.25V, and the SV-BAT-320 is fully charged.STANDBY: <strong>SkyView</strong> system voltage is above 10V, but below 12.25V: <strong>SkyView</strong> runs onmaster power but does not charge the SV-BAT-320. To conserve your aircraft battery,the SV-BAT-320 is only charged with <strong>SkyView</strong> detects your alternator/generator to beonline.NO BATTERY: No SV-BAT-320 is connected.Operational State of the Internal VoltagesThere are several important voltages in the display. You will find their statuses here. If they areall operating at specified levels, then you will see OK. If any voltage is operating out ofspecification, you will see X.XV FAIL for that voltage.Screen Brightness LevelThe screen's brightness level is shown here as a percent. For example, 100.0 means 100% and50.0 means 50%.Local Light Sensor OutputEach <strong>SkyView</strong> display has an integrated light sensor on the front bezel and its output is shownhere.External Light Control Signal Output<strong>SkyView</strong> displays are compatible with external light control signals. The state of the externallight control signal is shown here. This feature is not supported in the current release of<strong>SkyView</strong>.Brightness Level Output<strong>SkyView</strong> displays can output a brightness level signal to control the brightness of compatibleexternal equipment screens. The level of the output is shown here. This feature is notsupported in the current release of <strong>SkyView</strong>.Contact Input StatusEach <strong>SkyView</strong> display has four contact inputs. The status of each contact input is shown here aseither HIGH or LOW.17-6 <strong>SkyView</strong> <strong>System</strong> <strong>Installation</strong> <strong>Guide</strong> - Revision O

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!