Accessory <strong>Installation</strong> and ConfigurationIf you have more than one <strong>SkyView</strong> display, note that like all other serial devices, the encoderconverter module needs to be connected to a serial TX from each display simultaneously. Seethe Serial Devices section for more information about this requirement.Any general purpose <strong>SkyView</strong> display serial port is compatible with the Encoder Convertermodule. Connect the Encoder’s input (green or red) to an appropriate wire on the displayharness (reference the SV-D700 / SV-D1000 Electrical <strong>Installation</strong> Section for details on whichpins to use). Also ensure that the display and the Encoder Converter Module share a ground.Figure 94 illustrates the basic electrical connection between the <strong>SkyView</strong> display and theEncoder Converter module.Transponder<strong>SkyView</strong> DisplayDB37 ConnectorTXGND<strong>SkyView</strong> Display Serial TransmitShared GroundEncoder ConverterModuleGreen WireBlack WireYellowGreenWhite/BlueBlueOrangeWhite/RedWhite/GreenWhiteWhite/BlackUnconnectedUnconnectedA1A2A4B1B2B4C1C2C4D4StrobeThe Encoder Converter Moduleis compatible with all <strong>SkyView</strong>display serial ports.RedBlackFigure 94–Encoder Converter Module Electrical Connections10-30 voltsGroundSerial Port Setup–DYNON CONVERTER FormatEnter the Serial Port Setup Menu (SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP) oneach display and configure the appropriate serial port for use with the Encoder Serial-to-GrayCode Converter module with the following settings:SERIAL # IN DEVICE:NONESERIAL # IN FUNCTION:NONESERIAL # IN/OUT BAUD RATE: 1200SERIAL # OUT DEVICE: DYNON CONVERTERCapacitance-to-Voltage Converter <strong>Installation</strong> and Configuration<strong>Dynon</strong> <strong>Avionics</strong>’ Capacitance-to-Voltage Converter (<strong>Dynon</strong> P/N 100654-000) is suitable forgeneral use with most capacitive plate fuel level sensors. It accepts an input via a female BNCand outputs a DC voltage signal that can be read by the SV-EMS-220/221. It requires 10 to 15volts DC for power and draws minimal current. We recommend that you connect the<strong>SkyView</strong> <strong>System</strong> <strong>Installation</strong> <strong>Guide</strong> - Revision O 15-13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!