SV-EMS-220/221 <strong>Installation</strong> and ConfigurationExample Oil Temperature Sensor SetupAssume this sensor was mapped on the Sensor Input Mapping Wizard as:PIN # FUNCTION SENSOR NAMEC37 P7 TEMPERATURE 5/8”-18 NPT FLUID TEMP (100409-000) OILNow, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu andopen the OIL TEMPERATURE Page (SETUP MENU > EMS SETUP > SENSOR SETUP > OILTEMPERATURE).Configure OIL TEMPERATURE with the following properties: ALARM: LATCHING MAXIMUM GRAPHICAL DISPLAY: 260 °F MINIMUM GRAPHICAL DISPLAY: 80 °F RANGE 1o ENABLEYESo COLORYELLOWo TOP 165 °Fo BOTTOM 80 °F RANGE 2o ENABLEYESo COLORGREENo TOP 220 °Fo BOTTOM 165 °F RANGE 3o ENABLEYESo COLORYELLOWo TOP 240 °Fo BOTTOM 220 °F RANGE 4o ENABLEYESo COLORREDo TOP 260 °Fo BOTTOM 240 °F RANGE 5o ENABLENOo COLORREDo TOP 5 °Fo BOTTOM 0 °FFigure 46–Anatomy of aWidget: OilTemperatureNote that oil temperature is configured with a latching alarm in this example. If oiltemperature ever reaches a range configured as red, an alarm will trigger and amessage will show up in the message box on the Main Menu.7-62 <strong>SkyView</strong> <strong>System</strong> <strong>Installation</strong> <strong>Guide</strong> - Revision O