SV-EMS-220/221 Installation and ConfigurationExample Contact Sensor SetupAssume this sensor was mapped on the Sensor Input Mapping Wizard as:PIN # FUNCTION SENSOR NAMEC37 P9 CANOPY Contact CANOPYNow, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu andopen the CANOPY CONTACT Page (SETUP MENU > EMS SETUP > SENSOR SETUP > CANOPYCONTACT).Note that although inputs set up as contacts can physically accept up to 15V (sothat they can accept nominal aircraft voltage as one of their two states), themaximum the EMS can measure is 5.0V. This means that as depicted below, thetwo measured ranges should be set to 0-2.5V and 2.5-5V to measure the absenceand presence of power.Configure CANOPY CONTACT with the following properties: ALARM: OFF MAXIMUM GRAPHICAL DISPLAY: 5.0 VOLTS MINIMUM GRAPHICAL DISPLAY: 0.0 VOLTS RANGE 1o ENABLEYESo NAMEOPENo COLORREDo TOP5.0 VOLTSo BOTTOM2.5 VOLTS RANGE 2o ENABLEo NAMEo COLORo TOPo BOTTOM RANGE 3o ENABLEo NAMEo COLORo TOPo BOTTOM RANGE 4o ENABLEo NAMEo COLORo TOPo BOTTOM RANGE 5o ENABLEYESCLOSEDGREEN2.5 VOLTS0.0 VOLTSNOR3GREEN20.0 VOLTS10.0 VOLTSNOR4YELLOW10.0 VOLTS5.0 VOLTSNOFigure 44–Anatomyof a Widget: CanopyContact7-60 SkyView System Installation Guide - Revision O

Example RPM SetupSV-EMS-220/221 Installation and ConfigurationAssume this sensor was mapped on the Sensor Input Mapping Wizard as:PIN # FUNCTION SENSOR NAMEC37 P32/34 RPM RPM RPMNow, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu andopen the RPM RPM Page (SETUP MENU > EMS SETUP > SENSOR SETUP > RPM RPM).Configure RPM RPM with the following properties: ALARM: OFF MAXIMUM GRAPHICAL DISPLAY: 3000 RPM MINIMUM GRAPHICAL DISPLAY: 0 RPM RANGE 1o ENABLEYESo COLORGREENo TOP2000 RPMo BOTTOM0 RPM RANGE 2o ENABLEYESo COLORYELLOWo TOP2250 RPMo BOTTOM2000 RPM RANGE 3o ENABLEYESo COLORGREENo TOP2700 RPMo BOTTOM2250 RPM RANGE 4o ENABLEYESo COLORYELLOWo TOP2750 RPMo BOTTOM2700 RPM RANGE 5o ENABLEYESo COLORREDo TOP3000 RPMo BOTTOM2750 RPMFigure 45–Anatomy of aWidget: RPMSkyView System Installation Guide - Revision O 7-61

Example RPM SetupSV-EMS-220/221 <strong>Installation</strong> and ConfigurationAssume this sensor was mapped on the Sensor Input Mapping Wizard as:PIN # FUNCTION SENSOR NAMEC37 P32/34 RPM RPM RPMNow, we want to configure its alert and graphical properties. Go to the Sensor Setup Menu andopen the RPM RPM Page (SETUP MENU > EMS SETUP > SENSOR SETUP > RPM RPM).Configure RPM RPM with the following properties: ALARM: OFF MAXIMUM GRAPHICAL DISPLAY: 3000 RPM MINIMUM GRAPHICAL DISPLAY: 0 RPM RANGE 1o ENABLEYESo COLORGREENo TOP2000 RPMo BOTTOM0 RPM RANGE 2o ENABLEYESo COLORYELLOWo TOP2250 RPMo BOTTOM2000 RPM RANGE 3o ENABLEYESo COLORGREENo TOP2700 RPMo BOTTOM2250 RPM RANGE 4o ENABLEYESo COLORYELLOWo TOP2750 RPMo BOTTOM2700 RPM RANGE 5o ENABLEYESo COLORREDo TOP3000 RPMo BOTTOM2750 RPMFigure 45–Anatomy of aWidget: RPM<strong>SkyView</strong> <strong>System</strong> <strong>Installation</strong> <strong>Guide</strong> - Revision O 7-61

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!