SV-EMS-220/221 <strong>Installation</strong> and ConfigurationConnect the red wire to EMS pin 15 (12V power). Connect the black wire to ground (an SV-EMS-220/221 ground is appropriate). Connect the white wire to any of the “C” type inputs on the SV-EMS-220/221 module - pins 8, 22, or 31 only.Fuel Flow SensorThe approximate pulses/gallon setting for the FloScan 201B (i.e., cast metal caselegacy <strong>Dynon</strong> sensor) is 28,000 to 31,000. The approximate pulses/gallon for theElectronics International FT-60 (i.e., the red cube) is 68,000. You must configure thefuel flow sensor using this numerical value in the Sensor Setup Menu (SETUP MENU> HARDWARE CALIBRATION > EMS CALIBRATION > FUEL FLOW CALIBRATION).More information on this topic is discussed in the Fuel Computer Configurationsection of this chapter.7-40 <strong>SkyView</strong> <strong>System</strong> <strong>Installation</strong> <strong>Guide</strong> - Revision O