SV-EMS-220/221 <strong>Installation</strong> and Configuration36 Blue or Unwired Not connected37 Green or Unwired Not connectedTable 30–Example Rotax 912 37-pin Connector Sensor MapPinEMS 25-pin Thermocouple Sensor (with <strong>Dynon</strong> part number ifHarness Wire Colorapplicable)1 Open N/A2 Open N/A3 Open N/A4 Open N/A5 Open N/A6 Red N/A7 Red N/A8 Red N/A9 Red N/A10 Red N/A11 Red EGT 2 (K-type thermocouple, 100405-000*)12 Red N/A13 Red EGT 114 Open N/A15 Open N/A16 Open N/A17 Open N/A18 White N/A19 Yellow N/A20 White N/A21 Yellow N/A22 White N/A23 Yellow EGT 224 White N/A25 Yellow EGT 1Table 31–Example Rotax 912 25-pin Connector Sensor Map* Note that J-type and K-type thermocouples apply to all CHTs or EGTs, respectively. They arenot repeated in the table for brevity’s sake.7-24 <strong>SkyView</strong> <strong>System</strong> <strong>Installation</strong> <strong>Guide</strong> - Revision O