12.07.2015 Views

AC Frequency Inverters NXP / NXC - Andantex UK

AC Frequency Inverters NXP / NXC - Andantex UK

AC Frequency Inverters NXP / NXC - Andantex UK

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

vacon nxp controlThe Vacon <strong>NXP</strong> offers a high-performance control platform forall demanding drive applications. There are five slots (A, B, C, Dand E) for I/O boards, and a suitable board can be selected foreach slot (see table below).An external +24 V supply option enables communication withthe control unit even if the mains supply is switched off (e.g. forfieldbus communication and parameter setting).The Vacon <strong>NXP</strong> supports both induction motors and permanentmagnet motors in open and closed loop control modes.The Vacon <strong>NXP</strong> also supports special motors such as highspeedmotors.For closed loop control encoder, feedback from an incrementalpulse encoder is normally used. It is also possible to use absoluteencoders as the Vacon <strong>NXP</strong> is available with EnDat andresolver interfaces.A fast drive-to-drive communication is possible by usingVacon’s fast SystemBus fiber optic communication.option boardsType Card slot I / O signal12DI DO DI AI AI AO AO RO RO RO +10V refTherm +24V/ pt100 42-240 DI/DO DI/DO/ Resolver Out +5V/ Out Out +5V/A B C D E DO (mA/ (mA) (mA/V) (mA) (NO/ (NO) (NC)EXT V<strong>AC</strong> Encoder Encoder+15V/ +15V/ +12V/ NoteV/±V) isolated isolated NC)+24V input (10...24V) (RS422)+24V +24V +15VBasic I/O cards (OPT-A)OPT-A1 6 1 2 1 1 2OPT-A2 2OPT-A3 1 1 1OPT-A4 2 3/0 1OPT-A5 2 3/0 1OPT-A7 6/2 1 2 enc. input + 1 enc. outputOPT-A8 6 1 2 1 1 2 1)OPT-A9 6 1 2 1 1 2 2.5 mm 2 terminalsOPT-AE 2 3/0 1 DO = Divider+DirectionOPT-AF 2 2 1 3) Safe disable EN954-1, cat 3I/O expander cards (OPT-B)OPT-B1 6 1 Selectable DI/DOOPT-B2 1 1 1OPT-B4 1 2 1OPT-B5 3 2)OPT-B8 1 3OPT-B9 2 1 5OPT-BB 2 0/2 1 + EnDat + Sin/Cos 1 Vp-pOPT-BC 3/3 1 Encoder out = Resolver simulationFieldbus cards (OPT-C)OPT-C2 RS-485 (Multiprotocol) Modbus, N2OPT-C3Profibus DPOPT-C4LonWorksOPT-C5Profibus DP (D9-type connector)OPT-C6CANopen (slave)OPT-C7DeviceNetOPT-C8 RS-485 (Multiprotocol, D9-type connector) Modbus, N2OPT-CFCAN / EuromapOPT-CGSELMA 2 protocol (SAMI)OPT-CIModbus/TCP (Ethernet)Communication cards (OPT-D)OPT-D1System Bus adapter (2 x fiber optic pairs)OPT-D2System Bus adapter (1 x fiber optic pair) & CAN-bus adapter (galvanically decoupled)OPT-D3RS232 adapter card (galvanically decoupled), used mainly for application engineering to connect another keypadOPT-D6CAN-bus adapter (galvanically decoupled)NOTES: Allowed slots for the board are marked in blue.1) analogue signals galvanically isolated as a group2) analogue signals galvanically isolated separately3) certification pending

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!