Infrared Sensor to Control Temperature of Pots on Consumer Hobs ...

Infrared Sensor to Control Temperature of Pots on Consumer Hobs ... Infrared Sensor to Control Temperature of Pots on Consumer Hobs ...

dias.infrared.de
from dias.infrared.de More from this publisher
30.11.2012 Views

DIAS ong>Infraredong> GmbH – Publications – No. 3 1 ong>Infraredong> ong>Sensorong> ong>toong> ong>Controlong> ong>Temperatureong> ong>ofong> ong>Potsong> on Consumer Hobs Uwe Has, Bosch-Siemens Hausgeräte GmbH Jörg Schieferdecker, EG&G Heimann Opong>toong>electronics GmbH Dimitar Wassilew, DIAS ong>Infraredong> GmbH 1 Summary ong>ofong> the problem Anytime food is cooked in a pot the temperature ong>ofong> the food has ong>toong> be controlled carefully. Two major ways have been tried ong>toong> achieve an auong>toong>matic cooking system for hobs capable ong>toong> do this. First, measuring the temperature ong>ofong> the pot botong>toong>m by a contact probe [1] and, second, putting a temperature probe inong>toong> the food [2]. Both systems show problems: The thermal contact between a contact probe and the botong>toong>m is not reproducible. The heat ong>ofong> the heater disturbs the probe. Therefore, the signal provided by a contact probe is not accurate. ong>Temperatureong> probes ong>toong> put inong>toong> the food are difficult ong>toong> handle because they must be placed correctly. The temperature signal is ong>toong> be transferred ong>toong> a controller by wire. Furthermore, due ong>toong> hygienic and culinary reasons this system is not accepted everywhere. Therefore, these probes are not user friendly. A reliable and user friendly way ong>toong> measure the temperature ong>ofong> food is needed. 2 The new solution It has been suggested ong>toong> measure the temperature ong>ofong> the food without contact ong>ofong> food and probe by using an infrared-sensor [3]. The infrared sensor measures the temperature on the side ong>ofong> the pot. This paper describes the first infrared system suitable in hobs for mass production. 3 Technical implementation set point infrared sensor controller power Figure 1: Construction ong>ofong> hob with infrared sensor. Figure 1 shows the construction ong>ofong> a ceramic hob with infrared sensor. The temperature ong>ofong> the wall ong>ofong> the pot represent the temperature ong>ofong> the food ong>toong> be cooked. The pot is placed in front ong>ofong> the infrared sensor. The infrared detecong>toong>r is placed in a little sensor casing. It measures the temperature ong>ofong> a well defined spot on the side ong>ofong> the pot. The measuring spot is covered with enamel. The distance between pot and sensor is about 45 millimetres. The measuring spot is in a high ong>ofong> about 30 millimetres above

DIAS <str<strong>on</strong>g>Infrared</str<strong>on</strong>g> GmbH – Publicati<strong>on</strong>s – No. 3 1<br />

<str<strong>on</strong>g>Infrared</str<strong>on</strong>g> <str<strong>on</strong>g>Sensor</str<strong>on</strong>g> <str<strong>on</strong>g>to</str<strong>on</strong>g> <str<strong>on</strong>g>C<strong>on</strong>trol</str<strong>on</strong>g> <str<strong>on</strong>g>Temperature</str<strong>on</strong>g> <str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>Pots</str<strong>on</strong>g> <strong>on</strong> C<strong>on</strong>sumer <strong>Hobs</strong><br />

Uwe Has, Bosch-Siemens Hausgeräte GmbH<br />

Jörg Schieferdecker, EG&G Heimann Op<str<strong>on</strong>g>to</str<strong>on</strong>g>electr<strong>on</strong>ics GmbH<br />

Dimitar Wassilew, DIAS <str<strong>on</strong>g>Infrared</str<strong>on</strong>g> GmbH<br />

1 Summary <str<strong>on</strong>g>of</str<strong>on</strong>g> the problem<br />

Anytime food is cooked in a pot the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the food has <str<strong>on</strong>g>to</str<strong>on</strong>g> be c<strong>on</strong>trolled carefully. Two<br />

major ways have been tried <str<strong>on</strong>g>to</str<strong>on</strong>g> achieve an au<str<strong>on</strong>g>to</str<strong>on</strong>g>matic cooking system for hobs capable <str<strong>on</strong>g>to</str<strong>on</strong>g> do this. First,<br />

measuring the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the pot bot<str<strong>on</strong>g>to</str<strong>on</strong>g>m by a c<strong>on</strong>tact probe [1] and, sec<strong>on</strong>d, putting a temperature<br />

probe in<str<strong>on</strong>g>to</str<strong>on</strong>g> the food [2].<br />

Both systems show problems: The thermal c<strong>on</strong>tact between a c<strong>on</strong>tact probe and the bot<str<strong>on</strong>g>to</str<strong>on</strong>g>m is not<br />

reproducible. The heat <str<strong>on</strong>g>of</str<strong>on</strong>g> the heater disturbs the probe. Therefore, the signal provided by a c<strong>on</strong>tact<br />

probe is not accurate. <str<strong>on</strong>g>Temperature</str<strong>on</strong>g> probes <str<strong>on</strong>g>to</str<strong>on</strong>g> put in<str<strong>on</strong>g>to</str<strong>on</strong>g> the food are difficult <str<strong>on</strong>g>to</str<strong>on</strong>g> handle because they must<br />

be placed correctly. The temperature signal is <str<strong>on</strong>g>to</str<strong>on</strong>g> be transferred <str<strong>on</strong>g>to</str<strong>on</strong>g> a c<strong>on</strong>troller by wire. Furthermore,<br />

due <str<strong>on</strong>g>to</str<strong>on</strong>g> hygienic and culinary reas<strong>on</strong>s this system is not accepted everywhere. Therefore, these probes<br />

are not user friendly. A reliable and user friendly way <str<strong>on</strong>g>to</str<strong>on</strong>g> measure the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> food is needed.<br />

2 The new soluti<strong>on</strong><br />

It has been suggested <str<strong>on</strong>g>to</str<strong>on</strong>g> measure the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the food without c<strong>on</strong>tact <str<strong>on</strong>g>of</str<strong>on</strong>g> food and probe by<br />

using an infrared-sensor [3]. The infrared sensor measures the temperature <strong>on</strong> the side <str<strong>on</strong>g>of</str<strong>on</strong>g> the pot. This<br />

paper describes the first infrared system suitable in hobs for mass producti<strong>on</strong>.<br />

3 Technical implementati<strong>on</strong><br />

set point<br />

infrared sensor<br />

c<strong>on</strong>troller<br />

power<br />

Figure 1: C<strong>on</strong>structi<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> hob with infrared sensor.<br />

Figure 1 shows the c<strong>on</strong>structi<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> a ceramic hob with infrared sensor. The temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the wall<br />

<str<strong>on</strong>g>of</str<strong>on</strong>g> the pot represent the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the food <str<strong>on</strong>g>to</str<strong>on</strong>g> be cooked. The pot is placed in fr<strong>on</strong>t <str<strong>on</strong>g>of</str<strong>on</strong>g> the infrared<br />

sensor. The infrared detec<str<strong>on</strong>g>to</str<strong>on</strong>g>r is placed in a little sensor casing. It measures the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> a well<br />

defined spot <strong>on</strong> the side <str<strong>on</strong>g>of</str<strong>on</strong>g> the pot. The measuring spot is covered with enamel. The distance between<br />

pot and sensor is about 45 millimetres. The measuring spot is in a high <str<strong>on</strong>g>of</str<strong>on</strong>g> about 30 millimetres above


DIAS <str<strong>on</strong>g>Infrared</str<strong>on</strong>g> GmbH – Publicati<strong>on</strong>s – No. 3 2<br />

hobs surface. The signal <str<strong>on</strong>g>of</str<strong>on</strong>g> the infrared sensor is evaluated by a rule based c<strong>on</strong>trol algorithm. It is implemented<br />

in a 8 bit micro c<strong>on</strong>troller.<br />

4 Descripti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the sensing system<br />

The infrared radiati<strong>on</strong> emitted by the enamel passes trough a first window in<str<strong>on</strong>g>to</str<strong>on</strong>g> the sensor casing.<br />

Then, the radiati<strong>on</strong> is focused in<str<strong>on</strong>g>to</str<strong>on</strong>g> the sensor by a ellipsoid mirror. The radiati<strong>on</strong> passes in<str<strong>on</strong>g>to</str<strong>on</strong>g> the infrared<br />

detec<str<strong>on</strong>g>to</str<strong>on</strong>g>r trough a sec<strong>on</strong>d window. In the Figure 2 the sensor system is shown in detail.<br />

pot with enamel<br />

Figure 2: Detailed view <str<strong>on</strong>g>of</str<strong>on</strong>g> the sensor system<br />

c<strong>on</strong>cave<br />

mirror<br />

thermopile<br />

The window in the sensor casing and the <strong>on</strong>e in the thermopile are made <str<strong>on</strong>g>of</str<strong>on</strong>g> silic<strong>on</strong>. They form a<br />

spectral filter. This filter limits the spectral range used for the measurement from 6 µm <str<strong>on</strong>g>to</str<strong>on</strong>g> 15 µm. In<br />

this range the filter has an transmittance <str<strong>on</strong>g>of</str<strong>on</strong>g> about 70 % and nearly no absorpti<strong>on</strong>. In the spectral range<br />

from 6 µm <str<strong>on</strong>g>to</str<strong>on</strong>g> 15 µm the enamel shows an average emissivity <str<strong>on</strong>g>of</str<strong>on</strong>g> 0.9. This is the emissivity <str<strong>on</strong>g>of</str<strong>on</strong>g> dried<br />

food, <str<strong>on</strong>g>to</str<strong>on</strong>g>o. Therefore, the measurement is insensitive against this kind <str<strong>on</strong>g>of</str<strong>on</strong>g> dirt as it might stick <strong>on</strong> the<br />

side <str<strong>on</strong>g>of</str<strong>on</strong>g> the pot.<br />

The infrared detec<str<strong>on</strong>g>to</str<strong>on</strong>g>r is an uncooled thermopile [4]. It works in a temperature range from room<br />

temperature <str<strong>on</strong>g>to</str<strong>on</strong>g> 100 °C. During operati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the hob the typical ambient temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the thermopile<br />

is in the range <str<strong>on</strong>g>of</str<strong>on</strong>g> 30 °C <str<strong>on</strong>g>to</str<strong>on</strong>g> 60 °C. The thermopile c<strong>on</strong>tains a thermis<str<strong>on</strong>g>to</str<strong>on</strong>g>r <str<strong>on</strong>g>to</str<strong>on</strong>g> measure the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g><br />

the thermopile. Therefore, it is possible <str<strong>on</strong>g>to</str<strong>on</strong>g> compensate errors in measurement <str<strong>on</strong>g>of</str<strong>on</strong>g> the pot temperature<br />

caused by variati<strong>on</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> the ambient temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the thermopile. This compensati<strong>on</strong> is d<strong>on</strong>e by circuit<br />

placed <strong>on</strong> the printed circuit board inside the sensor casing.<br />

The ellipsoid mirror focused <strong>on</strong> a measuring spot <strong>on</strong> the side <str<strong>on</strong>g>of</str<strong>on</strong>g> the pot that has a diameter <str<strong>on</strong>g>of</str<strong>on</strong>g> less<br />

than 20 millimetres. This spot provides 95 % <str<strong>on</strong>g>of</str<strong>on</strong>g> the signal. Figure 3 shows the energy distributi<strong>on</strong> in<br />

the field <str<strong>on</strong>g>of</str<strong>on</strong>g> view <str<strong>on</strong>g>of</str<strong>on</strong>g> the sensor system. The different shades <str<strong>on</strong>g>of</str<strong>on</strong>g> grey indicate the relative intensity as<br />

given in the bar and the logarithmic diagram shown above. In Figure 3 the measuring spot is turned<br />

90° <str<strong>on</strong>g>to</str<strong>on</strong>g> the left side. That means, the upper side <str<strong>on</strong>g>of</str<strong>on</strong>g> the spot is <strong>on</strong> the left side in Figure 3.<br />

5°<br />

0°<br />

-5°<br />

-10° 0°<br />

10°<br />

Figure 3: Field <str<strong>on</strong>g>of</str<strong>on</strong>g> view <str<strong>on</strong>g>of</str<strong>on</strong>g> sensing system<br />

1.00<br />

0.10<br />

0.01


DIAS <str<strong>on</strong>g>Infrared</str<strong>on</strong>g> GmbH – Publicati<strong>on</strong>s – No. 3 3<br />

It has been tried <str<strong>on</strong>g>to</str<strong>on</strong>g> use a lens <str<strong>on</strong>g>to</str<strong>on</strong>g> focus the infrared radiati<strong>on</strong> in<str<strong>on</strong>g>to</str<strong>on</strong>g> the thermopile. The lens was made<br />

<str<strong>on</strong>g>of</str<strong>on</strong>g> polyethylene. In the spectral range used for the measurement this material has an absorpti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g><br />

about 40 %. The absorpti<strong>on</strong> affects the accuracy <str<strong>on</strong>g>of</str<strong>on</strong>g> the measurement. Therefore, this approach did not<br />

lead <str<strong>on</strong>g>to</str<strong>on</strong>g> success.<br />

The typical temperature resoluti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> a single sensor system is shown in Figure 4. At a pot temperature<br />

in the range from 80 °C <str<strong>on</strong>g>to</str<strong>on</strong>g> 100 °C and an emissivity <str<strong>on</strong>g>of</str<strong>on</strong>g> the enamel 90 % the sensor systems<br />

shows a sensitivity <str<strong>on</strong>g>of</str<strong>on</strong>g> about 27 mV/K.<br />

Under household c<strong>on</strong>diti<strong>on</strong>s heating <str<strong>on</strong>g>of</str<strong>on</strong>g> water is the most critical point. For set points in the range<br />

from 80 °C <str<strong>on</strong>g>to</str<strong>on</strong>g> 100 °C the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the food varies in the range <str<strong>on</strong>g>of</str<strong>on</strong>g> set point ±1.5 K if the operating<br />

instructi<strong>on</strong>s are observed.<br />

Due <str<strong>on</strong>g>to</str<strong>on</strong>g> <str<strong>on</strong>g>to</str<strong>on</strong>g>lerances in producti<strong>on</strong> every sensor system has <str<strong>on</strong>g>to</str<strong>on</strong>g> be calibrated after mounting in<str<strong>on</strong>g>to</str<strong>on</strong>g> the<br />

hob. Tolerances in the temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the food are not <strong>on</strong>ly caused by the sensor system itself. More<br />

important are <str<strong>on</strong>g>to</str<strong>on</strong>g>lerances in the emissivity <str<strong>on</strong>g>of</str<strong>on</strong>g> the enamel that forms the measuring spot.<br />

NETD in K<br />

temperature in °C<br />

0.08<br />

0.07<br />

0.06<br />

0.05<br />

0.04<br />

0.03<br />

0.02<br />

0.01<br />

0<br />

60 70 80 90 100 110 120 130 140 150 160 170 180 190 200<br />

90<br />

80<br />

70<br />

60<br />

50<br />

40<br />

30<br />

20<br />

10<br />

object temperature in °C<br />

Figure 4: Typical temperature resoluti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> a single sensor system<br />

temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> water<br />

signal <str<strong>on</strong>g>of</str<strong>on</strong>g> pcb with thermopile<br />

0<br />

1.5<br />

0 5 10 15 20 25 30 35 40<br />

time in min<br />

Figure 5: <str<strong>on</strong>g>Sensor</str<strong>on</strong>g> signal and temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> water during experiment<br />

2.5<br />

2.0<br />

signal in V


DIAS <str<strong>on</strong>g>Infrared</str<strong>on</strong>g> GmbH – Publicati<strong>on</strong>s – No. 3 4<br />

5 Experimental results<br />

Water was heated <str<strong>on</strong>g>to</str<strong>on</strong>g> test the temperature measurement. The set point was a temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> 85 °C.<br />

Figure 5 shows a chart <str<strong>on</strong>g>of</str<strong>on</strong>g> the water temperature and the signal <str<strong>on</strong>g>of</str<strong>on</strong>g> the infrared sensor during the experiment.<br />

The temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the water is measured with a thermocouple inside the water. The temperature<br />

signal obtained as an electrical voltage satisfies the needs <str<strong>on</strong>g>of</str<strong>on</strong>g> a temperature c<strong>on</strong>troller.<br />

6 C<strong>on</strong>clusi<strong>on</strong><br />

The IR-sensor-system c<strong>on</strong>sisting <str<strong>on</strong>g>of</str<strong>on</strong>g> enamel covering the measuring spot, a thermopile with correcti<strong>on</strong><br />

circuit, a filter and a focal mirror is suitable <str<strong>on</strong>g>to</str<strong>on</strong>g> provide a temperature measurement that can be<br />

used for c<strong>on</strong>trol purpose. If the ambient temperature <str<strong>on</strong>g>of</str<strong>on</strong>g> the thermopile stays in the range <str<strong>on</strong>g>of</str<strong>on</strong>g> 30 °C <str<strong>on</strong>g>to</str<strong>on</strong>g><br />

60 °C the error <str<strong>on</strong>g>of</str<strong>on</strong>g> the complete system is less than 1.5 K.<br />

7 References<br />

[1] W. Renz: Moderne Elektro-Kochstellen und ihre Steuer- und Regelelemente, Teil 1.<br />

elektrotechnik (1989) 5, S. 51-55<br />

[2] S. Koide, K. Hiejima: <str<strong>on</strong>g>Temperature</str<strong>on</strong>g> <str<strong>on</strong>g>C<strong>on</strong>trol</str<strong>on</strong>g>led Inducti<strong>on</strong> Heating and Cooking Apparatus.<br />

United States Patent 4,617,441<br />

[3] K. Wolf: Anordnung zum Messen der Temperatur in einem Heizsystem aus Heizplatte und<br />

Koch<str<strong>on</strong>g>to</str<strong>on</strong>g>pf. Deutsches Patent 33 41 234<br />

[4] J. Schieferdecker, M. Schulze, R. Quad, A. Beudt: Thermopile-IR-<str<strong>on</strong>g>Sensor</str<strong>on</strong>g>modul zur berührungslosen<br />

Temperaturmessung in Haushaltsgeräten. Wissenschaftliche Zeitung der Technischen<br />

Universität Dresden 43 (1994) 6, S. 41-44

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!