Smart - Serrata Science Equipment

Smart - Serrata Science Equipment Smart - Serrata Science Equipment

serrata.com.au
from serrata.com.au More from this publisher
12.07.2015 Views

TECHNOLOGYQSmartK-Type ThermocoupleAdaptor & ProbeLarge CandleReading Temperature 0 C1 4452 5943 4044 5395 459404 0 C445 0 C539 0 C459 0 C594 0 CThese results were obtained using Snapshot mode.The Copy Table option in Edit has been used tocopy the table into a word processing application.Birthday CandleReading Temperature 0 C1 2572 5363 496257 0 C496 0 C536 0 C●●●●●Comparing the temperature of different flames i.e. candles v bunsen burner.Investigating whether wax type in candles affects the rate of combustion.Discovering at what temperature popcorn pops – evaluating poppers andvarieties of popping corn.Melting point of copper, bismuth or other solids.Temperature of dry ice or liquid air.WarrantyAll Data Harvest Sensors are warranted to be free from defects in materials andworkmanship for a period of 12 months from date of purchase provided they havebeen used in accordance with any instructions, under normal laboratoryconditions. This warranty does not apply if the Sensor has been damaged byaccident or misuse.In the event of a fault developing within the 12-month period, the Sensor must bereturned to Data Harvest for repair or replacement at no expense to the user otherthan postal charges.Note: Data Harvest products are designed for educational use and are not intended for use inindustrial, medical or commercial applications.WEEE (Waste Electrical and Electronic Equipment) Legislation.Data Harvest Group Limited are fully compliant with WEEE legislation and arepleased to provide a disposal service for any of our products when their lifeexpires. Simply return them to us clearly identified as ‘life expired’ and we willdispose of them for you.3

TECHNOLOGYQ<strong>Smart</strong>K-Type ThermocoupleAdaptor & ProbeLarge CandleReading Temperature 0 C1 4452 5943 4044 5395 459404 0 C445 0 C539 0 C459 0 C594 0 CThese results were obtained using Snapshot mode.The Copy Table option in Edit has been used tocopy the table into a word processing application.Birthday CandleReading Temperature 0 C1 2572 5363 496257 0 C496 0 C536 0 C●●●●●Comparing the temperature of different flames i.e. candles v bunsen burner.Investigating whether wax type in candles affects the rate of combustion.Discovering at what temperature popcorn pops – evaluating poppers andvarieties of popping corn.Melting point of copper, bismuth or other solids.Temperature of dry ice or liquid air.WarrantyAll Data Harvest Sensors are warranted to be free from defects in materials andworkmanship for a period of 12 months from date of purchase provided they havebeen used in accordance with any instructions, under normal laboratoryconditions. This warranty does not apply if the Sensor has been damaged byaccident or misuse.In the event of a fault developing within the 12-month period, the Sensor must bereturned to Data Harvest for repair or replacement at no expense to the user otherthan postal charges.Note: Data Harvest products are designed for educational use and are not intended for use inindustrial, medical or commercial applications.WEEE (Waste Electrical and Electronic <strong>Equipment</strong>) Legislation.Data Harvest Group Limited are fully compliant with WEEE legislation and arepleased to provide a disposal service for any of our products when their lifeexpires. Simply return them to us clearly identified as ‘life expired’ and we willdispose of them for you.3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!