XPM0For Moeller Electric Sales and Support call KMparts.com (866) 595-9616poleX<strong>FI</strong>MAZ-3NAZXHI1116/2System overview<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s, residual-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sMoeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s7XUA99X<strong>FAZ</strong>pole<strong>FAZ</strong>11pole<strong>FAZ</strong>-21X<strong>FAZ</strong>X <strong>FAZ</strong>Xpole<strong>FAZ</strong>-331X<strong>FAZ</strong>-2pole<strong>FAZ</strong>Xpole<strong>FAZ</strong>XpoleXpoleXpole<strong>FAZ</strong>-4<strong>FAZ</strong>3XFSM411X<strong>FI</strong>LSpolePKNM213511XpoleX<strong>FI</strong>-40pole<strong>FI</strong>510AZ XAAX<strong>FI</strong>P-4pole<strong>FI</strong>-40AZ116AZ-2XFSM126AZ-386AZ<strong>FI</strong>M-4-125-0,36


System overview<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s, residual-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/3http://catalog.moeller.netBase unitsMoeller HPL0211-2007/2008Add-on functions<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s <strong>FAZ</strong> 1Characteristics/rated curent rangesB/4 … 63 A; C/0,5 … 63 A; D/6 … 40 ASwitching capacity:15 kA to IEC/EN 60947-2B, C, D characteristic1-, 1N-, 2-, 3-, 3N-, 4-poleSpecial miniature <strong>circuit</strong>-<strong>breaker</strong>s forauxiliary <strong>circuit</strong>s (1 and 2 pole)Special miniature <strong>circuit</strong>-<strong>breaker</strong> for DCapplicationsup to 500 V DCa page 16/4<strong>FAZ</strong>-PN miniature <strong>circuit</strong>-<strong>breaker</strong>s 2Characteristic/rated <strong>current</strong> rangesB/6 … 40 A; C/2 … 40 ASwitching capacity:6 kA to IEC/EN 60898B, C characteristic1 N polea page 16/8<strong>Residual</strong> <strong>current</strong> protective modules 3for attachment to <strong>FAZ</strong>Protection in the event of fault <strong>current</strong>Rated <strong>current</strong> range 40 … 63 ARated fault <strong>current</strong> 30 mA, 300 mAa page 16/12<strong>Residual</strong> <strong>current</strong> protective modules 12for attachment to AZProtection in the event of fault <strong>current</strong>Rated <strong>current</strong> range 80 … 125 ARated fault <strong>current</strong> 30 mA, 300 mAa page 16/12PKNM combined RCD/MCB <strong>device</strong> 4Overload, short-<strong>circuit</strong> protection andprotection with fault <strong>current</strong>sCharacteristic/rated <strong>current</strong> rangesB/6-40 A; C/6-40 A; 1N poleSwitching capacity:10 kA to IEC/EN 60898Rated fault <strong>current</strong> 30 mA, 300 mAa page 16/13<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s 5AC <strong>current</strong> sensitive2 pole 16 … 80 A4 pole 25 … 80 APulsed <strong>current</strong> sensitive2 pole 16 … 40 A4 pole 25 … 125 AAC/DC4 pole 40 … 125 ARated fault <strong>current</strong>30 mA, 100 mA, 300 mA, 500 mA4 pole selective, 63 … 80 ARated fault <strong>current</strong>100 mA, 300 mA4 pole frequency-inverter immune 40,63 A100 mA, 300 mAa page 16/14<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s AZ 6Characteristic/rated <strong>current</strong> ranges C/20-125 A; D/50-100 ASwitching capacity: 15 … 25 kA to IEC/EN 60947-2, 1-, 2-, 3-, 3N-, 4-polea page 16/10Auxiliary contacts <strong>FAZ</strong> 7Standard auxiliary contactsTrip-indicating auxiliary contactAuxiliary contactsa page 16/17Auxiliary contacts AZ 8Standard auxiliary contactsa page 16/17<strong>FAZ</strong> voltage releases 9Undervoltage releaseShunt releaseCan be fitted to <strong>FAZ</strong> or <strong>FAZ</strong>-<strong>FI</strong>Ma page 16/17Voltage releases AZ 10Shunt releasea page 16/17<strong>Residual</strong>-<strong>current</strong> auxiliary contact 13Auxiliary contactsa page 16/17Remote switching module 11Suitable for remote switching and automaticrestart of a miniature <strong>circuit</strong>-<strong>breaker</strong>or RCCB, for remote trip testing of aRCCB in conjunction with a remote testmodulea page 16/20<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


For Moeller Electric Sales and Support call KMparts.com (866) 595-961616/4Ordering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>sOrdering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/5<strong>FAZ</strong>-BMoeller HPL0211-2007/2008http://catalog.moeller.nethttp://catalog.moeller.netMoeller HPL0211-2007/2008<strong>FAZ</strong>-B<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sRated <strong>current</strong><strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s <strong>FAZ</strong>Characteristic BInstantaneous releaseresponse <strong>current</strong> 3 … 5x InSwitching capacity15 kA (IEC/EN 60947-2)I nA1 pole 2 pole 3 pole 4 pole 2 pole 4 polePart no.Article no.4 <strong>FAZ</strong>-B4/1-HS2792745 <strong>FAZ</strong>-B5/12785286 <strong>FAZ</strong>-B6/12785298 <strong>FAZ</strong>-B8/127853010 <strong>FAZ</strong>-B10/127853112 <strong>FAZ</strong>-B12/127853213 <strong>FAZ</strong>-B13/127853315 <strong>FAZ</strong>-B15/127853416 <strong>FAZ</strong>-B16/127853520 <strong>FAZ</strong>-B20/127853625 <strong>FAZ</strong>-B25/127853732 <strong>FAZ</strong>-B32/127853840 <strong>FAZ</strong>-B40/127853950 <strong>FAZ</strong>-B50/127854063 <strong>FAZ</strong>-B63/127854112Pricesee pricelistStd. packWith 2 protected poles With 3 protected poles With 4 protected poles With 1 protected pole, Nswitching with polePart no.Article no.12 off <strong>FAZ</strong>-B4/2-HS27927512<strong>FAZ</strong>-B6/2278728<strong>FAZ</strong>-B8/2278729<strong>FAZ</strong>-B10/2278730<strong>FAZ</strong>-B12/2278731<strong>FAZ</strong>-B13/2278732<strong>FAZ</strong>-B15/2278733<strong>FAZ</strong>-B16/2278734<strong>FAZ</strong>-B20/2278735<strong>FAZ</strong>-B25/2278736<strong>FAZ</strong>-B32/2278737<strong>FAZ</strong>-B40/2278738<strong>FAZ</strong>-B50/2278739<strong>FAZ</strong>-B63/227874034Pricesee pricelistStd.pack1off1 3 52 4 6Part no.Article no.<strong>FAZ</strong>-B6/3278841<strong>FAZ</strong>-B8/3278842<strong>FAZ</strong>-B10/3278843<strong>FAZ</strong>-B12/3278844<strong>FAZ</strong>-B13/3278845<strong>FAZ</strong>-B15/3278846<strong>FAZ</strong>-B16/3278847<strong>FAZ</strong>-B20/3278848<strong>FAZ</strong>-B25/3278849<strong>FAZ</strong>-B32/3278850<strong>FAZ</strong>-B40/3278851<strong>FAZ</strong>-B50/3278852<strong>FAZ</strong>-B63/3278853Pricesee pricelistStd.packPart no.Article no.1 off <strong>FAZ</strong>-B6/4279029<strong>FAZ</strong>-B8/4279030<strong>FAZ</strong>-B10/4279031<strong>FAZ</strong>-B12/4279032<strong>FAZ</strong>-B13/4279033<strong>FAZ</strong>-B15/4279034<strong>FAZ</strong>-B16/4279035<strong>FAZ</strong>-B20/4279036<strong>FAZ</strong>-B25/4279037<strong>FAZ</strong>-B32/4279038<strong>FAZ</strong>-B40/4279039<strong>FAZ</strong>-B50/4279040<strong>FAZ</strong>-B63/427904112354 678Pricesee pricelistStd.pack1 NPart no.Article no.1 off <strong>FAZ</strong>-B6/1N278642<strong>FAZ</strong>-B8/1N278643<strong>FAZ</strong>-B10/1N278644<strong>FAZ</strong>-B12/1N278645<strong>FAZ</strong>-B13/1N278646<strong>FAZ</strong>-B15/1N278647<strong>FAZ</strong>-B16/1N278648<strong>FAZ</strong>-B20/1N278649<strong>FAZ</strong>-B25/1N278650<strong>FAZ</strong>-B32/1N278651<strong>FAZ</strong>-B40/1N278652<strong>FAZ</strong>-B50/1N278653<strong>FAZ</strong>-B63/1N2786542N 2 4 6Pricesee pricelistStd.packWith 3 protected poles, Nswitching with polesPart no.Article no.1 off <strong>FAZ</strong>-B6/3N278943<strong>FAZ</strong>-B8/3N278944<strong>FAZ</strong>-B10/3N278945<strong>FAZ</strong>-B12/3N278946<strong>FAZ</strong>-B13/3N278947<strong>FAZ</strong>-B15/3N278948<strong>FAZ</strong>-B16/3N278949<strong>FAZ</strong>-B20/3N278950<strong>FAZ</strong>-B25/3N278951<strong>FAZ</strong>-B32/3N278952<strong>FAZ</strong>-B40/3N278953<strong>FAZ</strong>-B50/3N278954<strong>FAZ</strong>-B63/3N278955135NNPricesee pricelistStd.pack1 offNotesSwitching capacity(IEC/EN 60898)Switching capacity(IEC/EN 60947-2)10 kA15 kAAccessoriesAuxiliary contacts a 16/17Voltage releasesMounting accessories a 16/18<strong>FAZ</strong>-B4/1-HS, <strong>FAZ</strong>-B4/2-HS special miniature<strong>circuit</strong>-<strong>breaker</strong>s with much reduced let-throughenergy to prevent contact welding of auxiliarycontacts1 poleDepth 71 mmWidth 17.5 mm3 poleDepth 71 mmWidth 52.5 mm2-pole; 1N-poleDepth 71 mmWidth 35 mm4-pole; 3-pole + NDepth 71 mmWidth 70 mm<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s


For Moeller Electric Sales and Support call KMparts.com (866) 595-961616/6Ordering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>sOrdering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/7<strong>FAZ</strong>-C, <strong>FAZ</strong>-DMoeller HPL0211-2007/2008http://catalog.moeller.nethttp://catalog.moeller.netMoeller HPL0211-2007/2008<strong>FAZ</strong>-C, <strong>FAZ</strong>-D<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s <strong>FAZ</strong>Characteristic CInstantaneous releaseresponse <strong>current</strong> 5 … 10x I n Switching capacity 15kA (IEC/EN 60947-2)Rated <strong>current</strong>I nA1 pole 2 pole 3 pole 4 pole 2 pole 4 polePart no.Article no.0.5 <strong>FAZ</strong>-C0,5/12785441 <strong>FAZ</strong>-C1/12785461.6 <strong>FAZ</strong>-C1,6/12785482 <strong>FAZ</strong>-C2/12785493 <strong>FAZ</strong>-C3/12785514 <strong>FAZ</strong>-C4/12785536 <strong>FAZ</strong>-C6/12785558 <strong>FAZ</strong>-C8/127855610 <strong>FAZ</strong>-C10/127855713 <strong>FAZ</strong>-C13/127855916 <strong>FAZ</strong>-C16/127856120 <strong>FAZ</strong>-C20/127856225 <strong>FAZ</strong>-C25/127856332 <strong>FAZ</strong>-C32/127856440 <strong>FAZ</strong>-C40/127856550 <strong>FAZ</strong>-C50/127856663 <strong>FAZ</strong>-C63/127856712Pricesee pricelistStd. packWith 2 protected poles With 3 protected poles With 4 protected poles With 1 protected pole,N switching with polePart no.Article no.12 off <strong>FAZ</strong>-C0,5/2278743<strong>FAZ</strong>-C1/2278745<strong>FAZ</strong>-C1,6/2278747<strong>FAZ</strong>-C2/2278748<strong>FAZ</strong>-C3/2278750<strong>FAZ</strong>-C4/2278752<strong>FAZ</strong>-C6/2278754<strong>FAZ</strong>-C8/2278755<strong>FAZ</strong>-C10/2278756<strong>FAZ</strong>-C13/2278758<strong>FAZ</strong>-C16/2278760<strong>FAZ</strong>-C20/2278761<strong>FAZ</strong>-C25/2278762<strong>FAZ</strong>-C32/2278763<strong>FAZ</strong>-C40/2278764<strong>FAZ</strong>-C50/2278765<strong>FAZ</strong>-C63/22787661234Pricesee pricelistStd.pack1 3 52 4 6Part no.Article no.1 off <strong>FAZ</strong>-C0,5/3278856<strong>FAZ</strong>-C1/3278858<strong>FAZ</strong>-C1,6/3278860<strong>FAZ</strong>-C2/3278861<strong>FAZ</strong>-C3/3278863<strong>FAZ</strong>-C4/3278865<strong>FAZ</strong>-C6/3278867<strong>FAZ</strong>-C8/3278868<strong>FAZ</strong>-C10/3278869<strong>FAZ</strong>-C13/3278871<strong>FAZ</strong>-C16/3278873<strong>FAZ</strong>-C20/3278874<strong>FAZ</strong>-C25/3278875<strong>FAZ</strong>-C32/3278876<strong>FAZ</strong>-C40/3278877<strong>FAZ</strong>-C50/3278878<strong>FAZ</strong>-C63/3278879Pricesee pricelistStd.packPart no.Article no.1 off <strong>FAZ</strong>-C0,5/4279044<strong>FAZ</strong>-C1/4279046<strong>FAZ</strong>-C1,6/4279048<strong>FAZ</strong>-C2/4279049<strong>FAZ</strong>-C3/4279051<strong>FAZ</strong>-C4/4279053<strong>FAZ</strong>-C6/4279055<strong>FAZ</strong>-C8/4279056<strong>FAZ</strong>-C10/4279057<strong>FAZ</strong>-C13/4279059<strong>FAZ</strong>-C16/4279061<strong>FAZ</strong>-C20/4279062<strong>FAZ</strong>-C25/4279063<strong>FAZ</strong>-C32/4279064<strong>FAZ</strong>-C40/4279065<strong>FAZ</strong>-C50/4279066<strong>FAZ</strong>-C63/427906712354 678Pricesee pricelistStd.pack1 NPart no.Article no.1 off <strong>FAZ</strong>-C,5/1N278657<strong>FAZ</strong>-C1/1N278659<strong>FAZ</strong>-C1,6/1N278661<strong>FAZ</strong>-C2/1N278662<strong>FAZ</strong>-C3/1N278664<strong>FAZ</strong>-C4/1N278666<strong>FAZ</strong>-C6/1N278668<strong>FAZ</strong>-C8/1N278669<strong>FAZ</strong>-C10/1N278670<strong>FAZ</strong>-C13/1N278672<strong>FAZ</strong>-C16/1N278674<strong>FAZ</strong>-C20/1N278675<strong>FAZ</strong>-C25/1N278676<strong>FAZ</strong>-C32/1N278677<strong>FAZ</strong>-C40/1N278678<strong>FAZ</strong>-C50/1N278679<strong>FAZ</strong>-C63/1N2786802N 2 4 6Pricesee pricelistStd.packWith 3 protected poles, Nswitching with polesPart no.Article no.1 off <strong>FAZ</strong>-C0,5/3N278958<strong>FAZ</strong>-C1/3N278960<strong>FAZ</strong>-C1,6/3N278962<strong>FAZ</strong>-C2/3N278963<strong>FAZ</strong>-C3/3N278965<strong>FAZ</strong>-C4/3N278967<strong>FAZ</strong>-C6/3N278969<strong>FAZ</strong>-C8/3N278970<strong>FAZ</strong>-C10/3N278971<strong>FAZ</strong>-C13/3N278973<strong>FAZ</strong>-C16/3N278975<strong>FAZ</strong>-C20/3N278976<strong>FAZ</strong>-C25/3N278977<strong>FAZ</strong>-C32/3N278978<strong>FAZ</strong>-C40/3N278979<strong>FAZ</strong>-C50/3N278980<strong>FAZ</strong>-C63/3N278981135NNPricesee pricelistStd.pack1 offNotesSwitching capacity(IEC/EN 60898)Switching capacity(IEC/EN 60947-2)10 kA15 kAAccessories PageAuxiliary contacts, a 16/17voltage releasesMounting accessories a 16/181 poleDepth 71 mmWidth 17.5 mm3 poleDepth 71 mmWidth 52.5 mm2 pole; 1 N poleDepth 71 mmWidth 35 mm4 pole; 3N poleDepth 71 mmWidth 70 mm<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sCharacteristic DInstantaneous releaseresponse <strong>current</strong> 10 … 20x I n Switching capacity 15kA (IEC/EN 60947-2)6 <strong>FAZ</strong>-D6/12785788 <strong>FAZ</strong>-D8/127857910 <strong>FAZ</strong>-D10/127858013 <strong>FAZ</strong>-D13/127858216 <strong>FAZ</strong>-D16/127858420 <strong>FAZ</strong>-D20/127858525 <strong>FAZ</strong>-D25/127858632 <strong>FAZ</strong>-D32/127858740 <strong>FAZ</strong>-D40/127858812 off <strong>FAZ</strong>-D6/2278777<strong>FAZ</strong>-D8/2278778<strong>FAZ</strong>-D10/2278779<strong>FAZ</strong>-D13/2278781<strong>FAZ</strong>-D16/2278783<strong>FAZ</strong>-D20/2278784<strong>FAZ</strong>-D25/2278785<strong>FAZ</strong>-D32/2278786<strong>FAZ</strong>-D40/22787871 off <strong>FAZ</strong>-D6/3278890<strong>FAZ</strong>-D8/3278891<strong>FAZ</strong>-D10/3278892<strong>FAZ</strong>-D13/3278894<strong>FAZ</strong>-D16/3278896<strong>FAZ</strong>-D20/3278897<strong>FAZ</strong>-D25/3278898<strong>FAZ</strong>-D32/3278899<strong>FAZ</strong>-D40/32789001 off <strong>FAZ</strong>-D6/4279078<strong>FAZ</strong>-D8/4279079<strong>FAZ</strong>-D10/4279080<strong>FAZ</strong>-D13/4279082<strong>FAZ</strong>-D16/4279084<strong>FAZ</strong>-D20/4279085<strong>FAZ</strong>-D25/4279086<strong>FAZ</strong>-D32/4279087<strong>FAZ</strong>-D40/42790881 off <strong>FAZ</strong>-D6/3N278992<strong>FAZ</strong>-D8/3N278993<strong>FAZ</strong>-D10/3N278994<strong>FAZ</strong>-D13/3N278996<strong>FAZ</strong>-D16/3N278998<strong>FAZ</strong>-D20/3N278999<strong>FAZ</strong>-D25/3N279000<strong>FAZ</strong>-D32/3N279001<strong>FAZ</strong>-D40/3N2790021 off


16/8Ordering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>FAZ</strong>-PNMoeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>FAZ</strong>-PN miniature <strong>circuit</strong>-<strong>breaker</strong>sCharacteristic B Instantaneous releaseresponse <strong>current</strong> 3 … 5 x InSwitchingcapacity 6 kA (IEC/EN 60898)Rated <strong>current</strong>I nA2 poleWith 1 protected pole, Nswitching with pole1 N2NPart no.Article no.Pricesee price listStd. pack6 <strong>FAZ</strong>-PN-B6/1N27914610 <strong>FAZ</strong>-PN-B10/1N27914713 <strong>FAZ</strong>-PN-B13/1N27914816 <strong>FAZ</strong>-PN-B16/1N27914920 <strong>FAZ</strong>-PN-B20/1N27915025 <strong>FAZ</strong>-PN-B25/1N27915132 <strong>FAZ</strong>-PN-B32/1N27915240 <strong>FAZ</strong>-PN-B40/1N27915312 offAccessoriesAuxiliary contacts a 16/17Voltage releases1 N poleDepth 71 mmWidth 17.5 mmCharacteristic C Instantaneous releaseresponse <strong>current</strong> 5 … 10 x I n Switchingcapacity 6 kA (IEC/EN 60898)2 <strong>FAZ</strong>-PN-C2/1N2791544 <strong>FAZ</strong>-PN-C4/1N2791556 <strong>FAZ</strong>-PN-C6/1N27915610 <strong>FAZ</strong>-PN-C10/1N27915713 <strong>FAZ</strong>-PN-C13/1N27915816 <strong>FAZ</strong>-PN-C16/1N27915920 <strong>FAZ</strong>-PN-C20/1N27916025 <strong>FAZ</strong>-PN-C25/1N27916132 <strong>FAZ</strong>-PN-C32/1N27916240 <strong>FAZ</strong>-PN-C40/1N27916312 offFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616Ordering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong> for DC application16/9http://catalog.moeller.netMoeller HPL0211-2007/2008<strong>FAZ</strong>...-DCRated <strong>current</strong><strong>FAZ</strong> miniature <strong>circuit</strong>-<strong>breaker</strong>s for DCapplicationsCharacteristic CInstantaneous release response <strong>current</strong> 5… 10 x I nSwitching capacity 10 kA (IEC/EN 60947-2) (L/R = 4 ms)Rated voltage 250 V DC per poleI nA1 pole 2 poleWith 2 protected poles+ + –1 1 322 4–– +Part no.Article no.Pricesee pricelistStd. packPart no.Article no.Pricesee pricelistStd.pack<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s2 <strong>FAZ</strong>-C2/1-DC2791223 <strong>FAZ</strong>-C3/1-DC2791234 <strong>FAZ</strong>-C4/1-DC2791246 <strong>FAZ</strong>-C6/1-DC27912510 <strong>FAZ</strong>-C10/1-DC27912613 <strong>FAZ</strong>-C13/1-DC27912716 <strong>FAZ</strong>-C16/1-DC27912820 <strong>FAZ</strong>-C20/1-DC27912925 <strong>FAZ</strong>-C25/1-DC27913032 <strong>FAZ</strong>-C32/1-DC27913140 <strong>FAZ</strong>-C40/1-DC27913250 <strong>FAZ</strong>-C50/1-DC27913312 off <strong>FAZ</strong>-C2/2-DC279134<strong>FAZ</strong>-C3/2-DC279135<strong>FAZ</strong>-C4/2-DC279136<strong>FAZ</strong>-C6/2-DC279137<strong>FAZ</strong>-C10/2-DC279138<strong>FAZ</strong>-C13/2-DC279139<strong>FAZ</strong>-C16/2-DC279140<strong>FAZ</strong>-C20/2-DC279141<strong>FAZ</strong>-C25/2-DC279142<strong>FAZ</strong>-C32/2-DC279143<strong>FAZ</strong>-C40/2-DC279144<strong>FAZ</strong>-C50/2-DC2791451 offAccessoriesAuxiliary contacts a 16/17Voltage releasesMounting accessories a 16/181 poleDepth 71 mmWidth 17.5 mm2-pole; 1N-poleDepth 71 mmWidth 35 mmNoteCircuit design notesNote polarity!1 pole+12+250 V/L++–0 V/L––+–0 V/L–+250 V/L+2 pole+1–3++500 V/L+–0 V/L––+2– +40 V/L––++500 V/L++–


For Moeller Electric Sales and Support call KMparts.com (866) 595-961616/10Ordering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>sOrdering<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/11AZMoeller HPL0211-2007/2008http://catalog.moeller.nethttp://catalog.moeller.netMoeller HPL0211-2007/2008AZ<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sI nA<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s AZRated <strong>current</strong>1 pole 2 pole 3 pole 4 pole 4 poleWith 2 protected poles With 3 protected poles With 4 protection poles With 3 protection poles, N switchingwith poles12Part no.Article no.Pricesee pricelistStd. pack1234Part no.Article no.Pricesee pricelistStd. pack1 3 52 4 6Part no.Article no.Pricesee pricelistStd. pack12354 6Part no.Article no.78Pricesee price listStd. pack1352 4 6Part no.Article no.NNPricesee price listStd. packNotes<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sCharacteristic CInstantaneous releaseresponse <strong>current</strong> 5 … 10x I n Switching capacity15 … 25 kA (IEC/EN60947-2)20 AZ-C2021176925 AZ-C2521177432 AZ-C3221177940 AZ-C4021178450 AZ-C5021178963 AZ-C6321179480 AZ-C80211799100 AZ-C100211804125 AZ-C12521180912 off AZ-2-C20211770AZ-2-C25211775AZ-2-C32211780AZ-2-C40211785AZ-2-C50211790AZ-2-C63211795AZ-2-C80211800AZ-2-C100211805AZ-2-C1252118102 off AZ-3-C20211771AZ-3-C25211776AZ-3-C32211781AZ-3-C40211786AZ-3-C50211791AZ-3-C63211796AZ-3-C80211801AZ-3-C100211806AZ-3-C1252118111 off AZ-4-C20211772AZ-4-C25211777AZ-4-C32211782AZ-4-C40211787AZ-4-C50211792AZ-4-C63211797AZ-4-C80211802AZ-4-C100211807AZ-4-C1252118121 off AZ-3N-C20211773AZ-3N-C25211778AZ-3N-C32211783AZ-3N-C40211788AZ-3N-C50211793AZ-3N-C63211798AZ-3N-C80211803AZ-3N-C100211808AZ-3N-C1252118131 offFor switching capacity refer to TechnicalDataAccessoriesAuxiliary contacts, Voltagereleasesa 16/17Mounting accessories a 16/181 poleDepth 75 mmWidth 27 mm3 poleDepth 75 mmWidth 81 mm2 poleDepth 75 mmWidth 54 mm4-pole; 3N-poleDepth 75 mmWidth 108 mmCharacteristic DInstantaneous releaseresponse <strong>current</strong> 10 …20 x I n Switchingcapacity 15 … 25 kA(IEC/EN 60947-2)50 AZ-D5021181463 AZ-D6321181880 AZ-D80211822100 AZ-D10021182612 off AZ-2-D50211815AZ-2-D63211819AZ-2-D80211823AZ-2-D1002118272 off AZ-3-D50211816AZ-3-D63211820AZ-3-D80211824AZ-3-D1002118281 off AZ-3N-D50211817AZ-3N-D63211821AZ-3N-D80211825AZ-3N-D1002118291 off


16/12Ordering<strong>Residual</strong>-<strong>current</strong> protective modules for <strong>FAZ</strong> and AZ<strong>FI</strong>M, AZ<strong>FI</strong>MP, AZ<strong>FI</strong>MSMoeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sRateduninterrupted<strong>current</strong>I uA2 pole 4 polePart no.Article no.Pricesee pricelistStd.packPart no.Article no.Pricesee pricelistPart no.Article no.Pricesee pricelistStd.pack<strong>Residual</strong>-<strong>current</strong> protectivemodules for <strong>FAZ</strong>Rated fault<strong>current</strong> I DN = 30mARated fault<strong>current</strong> I DN =300 mA40 <strong>FI</strong>M-40/2/0,03-A27851063 <strong>FI</strong>M-63/2/0,03-A27851240 <strong>FI</strong>M-40/2/0,3-A27851163 <strong>FI</strong>M-63/2/0,3-A2785131 off <strong>FI</strong>M-40/4/0,03-A2785141 off <strong>FI</strong>M-63/4/0,03-A2785161 off <strong>FI</strong>M-40/4/0,3-A2785151 off <strong>FI</strong>M-63/4/0,3-A2785171 off1 off1 off1 off2 pole 4 pole 4 poleSelectiveRateduninterrupted<strong>current</strong>Part no.Article no.Pricesee pricelistStd.packPart no.Article no.Pricesee pricelistPart no.Article no.Pricesee pricelistStd.packI uA<strong>Residual</strong>-<strong>current</strong> protectivemodules for AZRated fault<strong>current</strong> I DN = 30mARated fault<strong>current</strong> I DN =300 mA80 AZ<strong>FI</strong>MP-4-80-0,03255484125 AZ<strong>FI</strong>MP-4-125-0,0325548880 AZ<strong>FI</strong>MP-2-80-0,3255477125 AZ<strong>FI</strong>MP-2-125-0,32554811 off AZ<strong>FI</strong>MP-4-80-0,32554851 off AZ<strong>FI</strong>MP-4-125-0,3255489AZ<strong>FI</strong>MS-4-80-0,3255492AZ<strong>FI</strong>MS-4-125-0,32554951 off1 off1 off1 offNotes <strong>FI</strong>M-.../2/... <strong>FI</strong>M-.../4/... AZ<strong>FI</strong>MP-2-... AZ<strong>FI</strong>MP-4-...AZ<strong>FI</strong>MS-4-...1' 3'/N 131' 3' 5' 7'/N 132 4TH2 4 6 8NTHTHTH2' 4'2' 4' 6' 8'N2' 4'/N 142' 4' 6' 8'/N 14For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


OrderingCombined RCD/MCB <strong>device</strong>s16/13http://catalog.moeller.netMoeller HPL0211-2007/2008PKNMRated <strong>current</strong>2 pole 2 pole1 N2 NPart no.Article no.HPricesee price listPart no.Article no.I nA Rated fault <strong>current</strong> I DN = 30 mA Rated fault <strong>current</strong> I DN = 300 mA1 N2 NHPricesee price listStd. pack<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sPKNM conbination switch, type ACharacteristic BSwitching capacity10 kA6 PKNM-6/1N/B/003-A-DW23858010 PKNM-10/1N/B/003-A-DW238640PKNM-6/1N/B/03-A-DW238582PKNM-10/1N/B/03-A-DW2386421 off13 PKNM-13/1N/B/003-A-DW238701PKNM-13/1N/B/03-A-DW23870316 PKNM-16/1N/B/003-A-DW238773PKNM-16/1N/B/03-A-DW23877520 PKNM-20/1N/B/003-A-DW238807PKNM-20/1N/B/03-A-DW23880925 PKNM-25/1N/B/003-A-DW238837PKNM-25/1N/B/03-A-DW23883932 PKNM-32/1N/B/003-A-DW238867PKNM-32/1N/B/03-A-DW23886940 PKNM-40/1N/B/003-A-DW238896PKNM-40/1N/B/03-A-DW238898Characteristic CSwitching capacity10 kA6 PKNM-6/1N/C/003-A-DW23859010 PKNM-10/1N/C/003-A-DW238650PKNM-6/1N/C/03-A-DW238592PKNM-10/1N/C/03-A-DW23865213 PKNM-13/1N/C/003-A-DW238713PKNM-13/1N/C/03-A-DW23871516 PKNM-16/1N/C/003-A-DW238785PKNM-16/1N/C/03-A-DW23878720 PKNM-20/1N/C/003-A-DW238817PKNM-20/1N/C/03-A-DW23881925 PKNM-25/1N/C/003-A-DW238847PKNM-25/1N/C/03-A-DW23884932 PKNM-32/1N/C/003-A-DW238877PKNM-32/1N/C/03-A-DW23887940 PKNM-40/1N/C/003-A-DW238906PKNM-40/1N/C/03-A-DW238908For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/14Ordering<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>FI</strong>...-AMoeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sRateduninterrupted<strong>current</strong>I uA2 pole 4 polePart no.Article no.<strong>Residual</strong> <strong>current</strong> <strong>device</strong> F1, Type ARated fault <strong>current</strong> I DN = 30 mA 16 <strong>FI</strong>-16/2/003-A279183Pricesee price listStd. pack1 offPart no.Article no.Pricesee price listStd. pack25 <strong>FI</strong>-25/2/003-A2791841 off <strong>FI</strong>-25/4/003-A2792131 off40 <strong>FI</strong>-40/2/003-A2791871 off <strong>FI</strong>-40/4/003-A27921763 <strong>FI</strong>-63/4/003-A27922180 <strong>FI</strong>-80/4/003-A279225100 <strong>FI</strong>-100/4/003-A/-102936125 <strong>FI</strong>-125/4/003-A279165Rated fault <strong>current</strong> I DN = 100 mA 25 <strong>FI</strong>-25/2/01-A2791851 off <strong>FI</strong>-25/4/01-A2792141 off40 <strong>FI</strong>-40/2/01-A2791881 off <strong>FI</strong>-40/4/01-A27921863 <strong>FI</strong>-63/4/01-A279222Rated fault <strong>current</strong> I DN = 300 mA 25 <strong>FI</strong>-25/2/03-A2791861 off <strong>FI</strong>-25/4/03-A2792151 off40 <strong>FI</strong>-40/2/03-A2791891 off <strong>FI</strong>-40/4/03-A27921963 <strong>FI</strong>-63/4/03-A27922380 <strong>FI</strong>-80/4/03-A279226100 <strong>FI</strong>-100/4/03-A/-102937125 <strong>FI</strong>-125/4/03-A279167Rated fault <strong>current</strong> I DN = 500 mA 25 <strong>FI</strong>-25/4/05-A2792161 off40 <strong>FI</strong>-40/4/05-A27922063 <strong>FI</strong>-63/4/05-A27922480 <strong>FI</strong>-80/4/05-A279227100 <strong>FI</strong>-100/4/05-A/-102938125 <strong>FI</strong>-125/4/05-A279169Notes 1 NF 100 A 125 A1 3 5 NH1HTTT3 572NH24 6N2 4 68For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616Ordering<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/15http://catalog.moeller.netMoeller HPL0211-2007/2008<strong>FI</strong>...-U, <strong>FI</strong>...-S/A, <strong>FI</strong>...-B4 poleRateduninterrupted<strong>current</strong>I uAPart no.Article no.Suitable for frequency inverters, type URated fault <strong>current</strong> I DN = 100 mA 40 <strong>FI</strong>-40/4/01-U27923463 <strong>FI</strong>-63/4/01-U279236Rated fault <strong>current</strong> I DN = 300 mA 40 <strong>FI</strong>-40/4/03-U27923563 <strong>FI</strong>-63/4/03-U279237Pricesee price listStd. pack1 offNotes1 3 5 NT2 4 6 NH<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sSelective and surge-proof 5 kA, type S/ARated fault <strong>current</strong> I DN = 100 mA 63 <strong>FI</strong>-63/4/01-S/A279228Rated fault <strong>current</strong> I DN = 300 mA 63 <strong>FI</strong>-63/4/03-S/A279229<strong>FI</strong>-80/4/03-S/A2792301 offT1 3 5NH24 6NSensitive to AC/DC, B typeRated fault <strong>current</strong> I DN = 30 mA 40 <strong>FI</strong>-40/4/003-B24071063 <strong>FI</strong>-63/4/003-B24071180 <strong>FI</strong>-80/4/003-B240712125 1) <strong>FI</strong>-125/4/003-B240717Rated fault <strong>current</strong> I DN = 100 mA 40 <strong>FI</strong>-40/4/01-B27917063 <strong>FI</strong>-63/4/01-B27917180 <strong>FI</strong>-80/4/01-B279172125 1) <strong>FI</strong>-125/4/01-B240722Rated fault <strong>current</strong> I DN = 300 mA 40 <strong>FI</strong>-40/4/03-B27917363 <strong>FI</strong>-63/4/03-B27917480 <strong>FI</strong>-80/4/03-B279175125 1) <strong>FI</strong>-125/4/03-B240727AC/DC, selective, B typeRated fault <strong>current</strong> I DN = 300 mA 40 <strong>FI</strong>-40/4/03-S/B28102263 <strong>FI</strong>-63/4/03-S/B28102380 <strong>FI</strong>-80/4/03-S/B2810241 off1 offT1357I >2 4 6 8For us in 50 Hz AC <strong>current</strong> systems with electrical equipment suchas frequency inverters, UPS systems of switched-mode powersupplies.During a malfunction electrical equipment can cause AC fault<strong>current</strong>s and pulsed DC fault <strong>current</strong>s as well as smooth pulsatingd.c. fault <strong>current</strong>, where RCCB's of type C will not trip. The residual<strong>current</strong> <strong>device</strong>s <strong>FI</strong>-B detects all fault <strong>current</strong> types in accordancewith the tripping characteristic B of the IEC 60755, i.e. evenpulsating d.c. fault <strong>current</strong>• Caution: In some countries the insurance companies placespecial demands on RCCS's.• Contact position display red-green• Position independent function• Trip occurs independent of the mains voltage (<strong>current</strong>s type ACand A)• 30 V AC necessary for detection of type B <strong>current</strong>• Mains connection side top• Type S/B 40 ms delay and selective switch off• Auxiliary contacts on requestNotes1) Neutral pole right, at 125 A neutral pole on left


16/16Ordering<strong>Residual</strong> <strong>current</strong> <strong>device</strong>s <strong>FI</strong> for export<strong>FI</strong>Moeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sRateduninterrupted<strong>current</strong>I uA2 pole 4 pole 4 poleSelective and surge-proof 5kAPart no.Article no.Pricesee price listStd. packPart no.Article no.Pricesee price listStd. packPart no.Article no.Pricesee price listStd. pack<strong>FI</strong> residual-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s,only for export (AC type)Rated fault <strong>current</strong> I DN= 30 mA16 <strong>FI</strong>-16/2/0032791761 off25 <strong>FI</strong>-25/2/003279177<strong>FI</strong>-25/4/0032791961 off40 <strong>FI</strong>-40/2/003279180<strong>FI</strong>-40/4/00327920063 <strong>FI</strong>-63/2/003279190<strong>FI</strong>-63/4/00327920480 <strong>FI</strong>-80/2/003279192<strong>FI</strong>-80/4/003279208Rated fault <strong>current</strong> I DN= 100 mA25 <strong>FI</strong>-25/2/012791781 off <strong>FI</strong>-25/4/012791971 off40 <strong>FI</strong>-40/2/01279181<strong>FI</strong>-40/4/0127920163 <strong>FI</strong>-63/2/01279191<strong>FI</strong>-63/4/01279205<strong>FI</strong>-63/4/01-S2792101 off80 <strong>FI</strong>-80/2/01279193<strong>FI</strong>-80/4/01279231Rated fault <strong>current</strong> I DN= 300 mA25 <strong>FI</strong>-25/2/032791791 off <strong>FI</strong>-25/4/032791981 off40 <strong>FI</strong>-40/2/032791821 off <strong>FI</strong>-40/4/0327920263 <strong>FI</strong>-63/4/03279206<strong>FI</strong>-63/4/03-S2792111 off80 <strong>FI</strong>-80/4/03279209<strong>FI</strong>-80/4/03-S2792121 offRated fault <strong>current</strong> I DN= 500 mA25 <strong>FI</strong>-25/4/0527919940 <strong>FI</strong>-40/4/0527920363 <strong>FI</strong>-63/4/05279207Notes1N1 3 5NTHTH2N24 6NFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.netMoeller HPL0211-2007/2008OrderingAuxiliary contacts, voltage releases, MCB lock<strong>FAZ</strong>-X, AZ-X, <strong>FI</strong>P-X16/17ContactsNumberContactsequenceSpace units 1 SU= 18 mmSUPart no.Article no.Auxiliary contacts and voltage releasesAuxiliary contacts for <strong>FAZ</strong>, AZ, PKNM13 21<strong>FAZ</strong>Up to 63 A 1 N/O/1 N/C 0.5 <strong>FAZ</strong>-XHIN11PKNM2860541 C/O 12 140.5 <strong>FAZ</strong>-XHINW1286055AZ Up to 125 A 1 N/O/1 N/C 1.13 1.21 0.5 AZ-XHI112120671114 22Pricesee price listStd. pack10 off10 off10 off<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s1.14 1.22Trip-indicating auxiliary contact for <strong>FAZ</strong>, PKNM 1)<strong>FAZ</strong>PKNMUp to 63 A 2 C/O 1.12 1.14 4.12 4.14 0.5 <strong>FAZ</strong>-XAM00226241410 offAuxiliary contact for <strong>FI</strong><strong>FI</strong> Up to 100 A 1 N/O/1 N/C 1.13 1.21 0.5 <strong>FI</strong>P-XHI112251211.114.1110 off<strong>FI</strong> 2)From 125 A andType B1.14 1.221 N/O/1 N/C 1.12 1.14 1.21 0.5 <strong>FI</strong>PA-XAM01126257810 offShunt releases for <strong>FAZ</strong>, AZ, PKNM<strong>FAZ</strong>PKNM<strong>FAZ</strong>PKNM1.11 1.22Up to 63 A C11 <strong>FAZ</strong>-XAA-C-12-110VAC278518C2Up to 63 A C11 <strong>FAZ</strong>-XAA-C-110-415VAC27851910 off10 offAZ Up to 125 A C11.5 AZ-XAA(110-415VAC)212059AZ Up to 125 A C11.5 AZ-XAA(12-60VAC)212061Undervoltage releases for <strong>FAZ</strong><strong>FAZ</strong> D1U1 <strong>FAZ</strong>-XUA(115VAC)212049<strong>FAZ</strong>D21 <strong>FAZ</strong>-XUA(230VAC)212051<strong>FAZ</strong> 1 <strong>FAZ</strong>-XUA(400VAC)212053Lockout<strong>device</strong> for<strong>FAZ</strong>/<strong>FI</strong>P– IS/SPE-1TE101911C2C2C210 off10 off10 off10 off10 off10 offNotes 1) The <strong>device</strong> is supplied with the groove in the yellow selector button in the horizontal: Changeover contact 4.11 … 4.12/4.14switches when tripped manually or electrically. Turning the yellow selector button by 90° results in contact 4.11 … 4.12/4.14responding only to electrical tripping: the contact 4.11 … 4.12/4.14 remains closed when tripped by hand.2) The <strong>device</strong> is supplied with the “Auxiliary contact” function set such that both contacts switch on manual and electrical tripping. Achange of function to “Signalling switch” means that both contacts switch only under fault conditions.AC-11, 230 V DC/6 ADC-11, 230 V DC/1 AMinimum voltage: 12 V AC/DCMinimum <strong>current</strong>: 100 mATerminal capacity: 1 x 2.5 mm 2 , 2 x 1.5 mm 2Max. tightening torque: 0.8 Nm


OrderingMounting accessories16/19http://catalog.moeller.netMoeller HPL0211-2007/2008Ratedoperational<strong>current</strong>No. ofpolesI eA mm 2 mCross-section Length Part no.Article no.Mounting accessories1-phase, 80 A 80 1 16 1 Z-GV-16/1P-1TE2710613-phase, 63 A 63 3 10 1 Z-GV-10/3P-3TE271060End caps for Z-GV-10/3P-3ST – 3 10 – Z-AK-10/2+3P271069Pricesee price listStd. pack50 off20 off10 off<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s80 3 16 1 Z-GV-16/3P-3TE27106420 off– 3 16 – Z-AK-16/2+3P27107010 off80 4 16 1 Z-GV-16/3P+N-4TE27106615 off– 4 16 – Z-AK-16/4P27107110 offFeeder blockWith end feeder max. 80 Awith center feeder max. 125 A– – 1 x 251 x 50– <strong>FAZ</strong>/<strong>FI</strong>P-XVS-KL21210912 offIncoming terminals4,3 Nm, touch-proof busbar connection to miniature<strong>circuit</strong>-<strong>breaker</strong>M5: 3.0 Nm, M8: 4.3 Nm Touch-proof connection to<strong>FAZ</strong>-XIS... busbar– – 25 – <strong>FAZ</strong>-XK25212116– – 35 – <strong>FAZ</strong>-XK3521211950 off10 offProtective coversFor shrouding unused terminals on the busbar – – – ZV-BS-G104903Bracket for securing the covers 2 off required per group ofMCB's– – – REG-BB2121061 off20 offRated operational<strong>current</strong>LengthPart no.Article no.Pricesee price listStd. packI eAmExtension terminals, 80 ASame extension terminal, turned by 180°Busbars1m long.Shroud section1m long, for 50 and 80 A.End cap for shroudL1, N 80 – ZV-L1/N-80A-10263950L1, N 80 – ZV-L1/N-80A-36263951L1, N 80 – ZV-L1/N-80A-100263952L2, L3 80 – ZV-L2/L3-80A-10263953L2, L3 80 – ZV-L2/L3-80A-36263954L2, L3 80 – ZV-L2/L3-80A-10026395550 1 ZV-SS26395680 1 ZV-SS-80A263957– – ZV-ADP263958– – ZV-AEK26395910 off36 off100 off10 off36 off100 off10 off10 off100 off10 offFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


For Moeller Electric Sales and Support call KMparts.com (866) 595-961616/20OrderingRemote switching modules, fuse bases<strong>FAZ</strong>-<strong>FI</strong>P, Z-FW, D0…-SOMoeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sPart no.Article no.Remote switching modules• IEC/EN 60669-2-2• For remote switching and automatic miniature <strong>circuit</strong>-<strong>breaker</strong>s <strong>FAZ</strong> and residual <strong>current</strong> <strong>device</strong>s <strong>FI</strong> up to 80 Awith the exception ot type B• Mechanically lockable and sealable• Operating and alarm display via LED• Mechanical switching capability up to <strong>FAZ</strong>-…63 or <strong>FI</strong>-80… with the exception of type B (-XFSM)• …25 °C/+40 °C• Rated operational voltage 24 … 240 V AC, 24 … 48 V DC• Terminal capacity 2 x 1.5 mmB, 1 x 2.5 mmB; 0.4 Nm• Mechanical/electrical live 10,000 switching operations• Power consumption 5 W220 … 240 V AC <strong>FAZ</strong>/<strong>FI</strong>P-XAWM26251448 V DC <strong>FAZ</strong>/<strong>FI</strong>P-XDWM274404Pricesee price listStd. pack1 off1 offRemote test module• External test module with test resistor for RCCB <strong>device</strong>s• Version adapted for rated fault <strong>current</strong>s with stipulated “external” test button function0.01 A Z-FW/0012482970.03 A Z-FW/0032482980.1 A Z-FW/0102482990.3 A Z-FW/0302483000.5 A Z-FW/0502483014 off4 off4 off4 off4 offPoleRatedoperational<strong>current</strong>Ratedoperationalvoltage<strong>Fuse</strong>cartridgePart no.Article no.Pricesee pricelistStd. packNotesI eU e<strong>Fuse</strong> baseA V AC Size1 pole 16 – D01 D01-SO/16/11027521 pole 63 – D02 D02-SO/63/11026751 off Equipment supplied:Empty, without1 off screw on cover3 pole 16 – D01 D01-SO/16/31026743 pole 63 – D02 D02-SO/63/31026761 off1 off


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616OrderingMounting accessories16/21http://catalog.moeller.netMoeller HPL0211-2007/2008For use withTerminalcapacity forroundconductormm 2Part no.Article no.Covers for 1-pole fuse basesStandard dimension 45 mmS...-1/... – P-E14086182S...-1/... – P-E18088555S...-1/... – P-E27090928S...-1/... – P-E33093301Transparent shroudWith cable entry knockouts top and bottom – – H-S27-1029118Busbar connector 63 AFor fuse bases, 3 pole D0.../3 – Z-SV-16/3P271072CoverFor busbar block Z-SV-16/3P – Z-AK-16/2+3P271070Notched phase busbars, can be cut to lengthPricesee pricelistStd. pack20 off20 off10 off10 off10 off20 off10 offNotes<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>sFor gauge ring (gauge screw: /FORMP)990 mm long, for max. 36 fuse bases, rated <strong>current</strong> 100 A990 mm long, for max. 36 fuse bases, rated <strong>current</strong> 160 A980 mm long, for max. 22 fuse bases, rated <strong>current</strong> 100 A960 mm long, for max. 18 fuse bases, rated <strong>current</strong> 160 ATerminalsS14-1/CS18-1/CS27-1/CS33-1/CKS14050502KS18052875KS27055248KS330599945 off5 off5 off5 offFor gauge ring (gauge screw: /FORMP)For round conductors up to 35 mm 2 or flat conductors 6 x 9 x 0.8KS14 – KS33K35-AB06433920 offFor retrofitting as PE/N terminalS27/1 a 1.5 – 6 K6/1002270S33/1 a 4 … 16s 4 … 16q 4 … 10K16/1002272100 off Terminal capacitya solids strandedq flexible with25 off ferruleDimensions (W x H x D)Rated operational<strong>current</strong>I eCu factorPart no.Article no.Pricesee pricelistStd. packmmABusbarsFlat copper busbars, tinned12 x 5 Supplied in lengths of 1500 mm 160 0,81 CU12X503412120 x 5 Supplied in lengths of 1500 mm 250 1,34 CU20X504409220 x 10 Supplied in lengths of 1500 mm 400 2,68 CU20X1004171910 off10 off5 off


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/22OrderingBusbar mounting switch-disconnectorD02, Z-D0...Busbar mounting switch-disconnectorWith fuses D02-S/63/3-RS for 60 mm distancebetween busbar centres• 3 pole, 36 mm• Supplied empty and without screw on cover<strong>Fuse</strong> cartridgeSizeMoeller HPL0211-2007/2008Rated uninterrupted<strong>current</strong>I uAPart no.Article no.D02 max. 63 D02-S/63/3-RS284649<strong>Fuse</strong>s, utilisation class gG (gL)• Snap-fit on DIN rail• in a plastic box in the colour of the indicatorD01 24Z-D01/SE-2288934Z-D01/SE-42889356 Z-D01/SE-628893610 Z-D01/SE-1028893713 Z-D01/SE-1328893816 Z-D01/SE-16288939D02 20 Z-D02/SE-2028894025 Z-D02/SE-2528894132 Z-D02/SE-3228894235 Z-D02/SE-3528894340 Z-D02/SE-4028894450 Z-D02/SE-5028894563 Z-D02/SE-63288946Gauge ringD01 2 Z-D01/PE-2• D01 for fuse base D02 and fuse switchdisconnector288909D024 Z-D01/PE-4• Snap-fit on DIN rail288910• in a plastic box in the colour of the indicator6 Z-D01/PE-628891110, 13 Z-D01/PE-10288912D02 20 Z-D02/PE-2028891325 Z-D02/PE-2528891435, 32 Z-D02/PE-3528891540 Z-D02/PE-4028891650 Z-D02/PE-50288917• D01 for fuse base D02 and fuse switchdisconnectorD02-D01 2 Z-D02-D01/PE-2D02263112• Snap-fit on DIN rail4 Z-D02-D01/PE-4• in a plastic box in the colour of the indicator2631136 Z-D02-D01/PE-626315010, 13 Z-D02-D01/PE-1026315116 Z-D02-D01/PE-16263152Screw cap D01 max. 16 Z-D01/SK100650D02 max. 63 Z-D02/SK100651http://catalog.moeller.netPricesee pricelistStd. pack1 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off1 off1 offSpring• For inserting D01 fues links in the screw cap Z-D02/SKD02-D01Z-D02/SIKA-HF26314950 off


16/24Ordering<strong>Fuse</strong> setsZ-SLS, Z-SLZMoeller HPL0211-2007/2008http://catalog.moeller.netRated uninterrupted<strong>current</strong><strong>Fuse</strong> cartridgePart no.Article no.Pricesee price listStd. pack<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Fuse</strong> setsRated operational voltage 60 … 400 VACI uASize1 Z-SLS/B-1A2689832 Z-SLS/B-2A2689844 Z-SLS/B-4A2689856 Z-SLS/B-6A26898610 Z-SLS/B-10A26898713 Z-SLS/B-13A28997216 Z-SLS/B-16A26898820 Z-SLS/B-20A26898925 Z-SLS/B-25A26899032 Z-SLS/B-32A28997335 Z-SLS/B-35A26899140 Z-SLS/B-40A28997450 Z-SLS/B-50A26899263 Z-SLS/B-63A268993Dissconnector kit• For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK• Snap-fit on DIN rail• 1 set consists of: 3 switch conversion sets, 3 <strong>current</strong> codings, 1 plastic box• The fuse switch-disconnector is thus converted to a switch-disconnector.63 Z-SLS/TR-SET10066012 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off12 off1 offSwitch-on inhibits• For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK• Only 1 stop required per <strong>device</strong>Stop with metal lockStop with plastic lockZ-SLZ/SC268980Z-SLZ/SP26898112 off12 offIncoming double terminal• For Z-SLS/NEOZ, Z-SLK/NEOZ, Z-SLS/CEK•2 x 3 x 35 mm 2 Z-SLZ/KL26898215 offFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


Ordering<strong>Fuse</strong> switch-disconnector16/25http://catalog.moeller.netMoeller HPL0211-2007/2008VLCPolePart no.Article no.<strong>Fuse</strong> switch-disconnectors, empty• For cylindrical fusesSize 14 x 51, up to 50 AWithout flashing function 1 VLC14-1P2853611 + N VLC14-1P+N2853622 VLC14-2P285363Pricesee price listStd. pack12 off12 off12 off<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s3 VLC14-3P28536412 off3 + N VLC14-3P+N28536512 offWith flashing function 1 VLC14-1P/L28537112 off1 + N VLC14-1P+N/L28537212 off2 VLC14-2P/L28537312 off3 VLC14-3P/L28537412 off3 + N VLC14-3P+N/L28537512 offSize 22 x 58, up to 100 AWithout flashing function 1 VLC22-1P28536612 off1 + N VLC22-1P+N28536712 off2 VLC22-2P28536812 off3 VLC22-3P28536912 off3 + N VLC22-3P+N28537012 offWith flashing function 1 VLC22-1P/L28537612 off1 + N VLC22-1P+N/L28537712 off2 VLC22-2P/L28537812 off3 VLC22-3P/L28537912 off3 + N VLC22-3P+N/L28538012 offFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/26OrderingLV h.b.c. fuse bases, LV h.b.c. fuse switch-disconnectorsGS…, GST…Moeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sIntervalbetweenbusbarcentresBusbarsizeRatedoperational<strong>current</strong>Max. fuseI e 500 V 690 V Sizemm mm A A APart no.Article no.Low-voltage h.b.c. fuse bases3-pole– – 160 160 100 NH00 GS00-160026741Pricesee price listStd. pack1 off– – 250 250 200 NH1 GSU12890161 off– 400 400 315 NH2 GSU22890171 off– 630 630 500 NH3 GSU32890181 offLowvoltage h.b.c. fuse switchdisconnectorsfor fitting to mounting plate, MR251 poleWithout handguard– 160 160 100 NH00 GSTA00-160-1P 1)2250001 off3 poleWithout handguard– 160 160 100 NH00 GSTA00-160095558– 250 250 200 NH1 GSTA1017250– 400 400 315 NH2 GSTA2021996– 630 630 500 NH3 GSTA30267421 off1 off1 off1 offFor mounting on busbars, flat busbars3 poleWithout handguard3-pole60 12 … 30x 5 … 10100 100 NH000 LTS-100/C00/3-R2846901 offWithout handguardConnectiontop andbottom40/50/60 12 … 30x 5 … 10160 160 100 NH00 GST00-160-40-60-AOU2245501 offFor mounting on busbars3 poleWith hand guardConnection atbottom60 20 … 30x 5 … 10250 250 200 NH1 GST1-AU1072511 off400 400 315 NH2 GST2-AU1072531 off630 630 500 NH3 GST3-AU1072551 offConnection attop250 250 200 NH1 GST1-AO1072501 off400 400 315 NH2 GST2-AO1072521 off630 630 500 NH3 GST3-AO1072541 offNotes1) Can be fitted to GSTA00-160 for 4-pole low-voltage h.b.c. fuse switch-disconnectorTwo <strong>device</strong>s can be combined to make a 2-pole low-voltage h.b.c. fuse switch-disconnectorFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


OrderingNH fuse mounting accessories16/27http://catalog.moeller.netMoeller HPL0211-2007/2008C-GST, PSK, ZBSClip setCan be retrofitted, adjustableFor latching on to two top-hat rails to IEC/EN 60715 (35 mm)For distances of 100 to 125 mm between busbar centresFor use withGSTA00-160Part no.Article no.C-GSTA00040922Sets of clamp-type terminalsOne set comprises 3 clamptype terminalsTerminal range 1 x (70 150) mmB Cu/Al GSU1, GST...1 PSK1038734Pricesee price listStd. pack5 off1 off<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sTerminal range 1 70 150) mmB Cu/Al GSU2, GST...2 PSK20434801 offTerminal range 1 x (120 300) mmB Cu/Al GSU3, GST...3 PSK30482261 offSets of double clamp-type terminalsOne set comprises of 3 double clamptype terminals.Terminal range 2 x (70 95) mmB Cu/Al GSU1, GST...1 PSK120411071 offTerminal range 2 x (120 150) mmB Cu/Al GSU2, GST...2 PSK220458531 offTerminal range 2 x (120 240) mmB Cu/Al GSU3, GST...3 PSK320505991 offHand guard for fuse switch-disconnectorsProvides additional protection for the operator during actuation of the fuse-switch disconnectorGST00...GSTA00...GSTA1GSTA2GSTA3ZBS-GSTA00014411ZBS-GSTA1082800ZBS-GSTA2082801ZBS-GSTA308280210 off10 off5 off1 offInsulating surround for fuse switch-disconnectorsFor compensation between the GA… protective cover and the <strong>device</strong>(for use in the CI insulated distribution board system)GST00B-GST00-40-60/CI/12245535 offFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/28OrderingLow-voltage h.b.c. switch-fuse unitsNH-SLS, Z-NHMoeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sRated operational <strong>current</strong> <strong>Fuse</strong> cartridge Part no.Article no.I eASizeLow-voltage h.b.c. switch-fuse units NH-SLS, 3 pole• With connection area cover• Mounting without holes with spike type terminalEquipment supplied• NH-SLS-00/160(-SI): with spike-type terminal and clamp terminal• NH-SLS-00/160-60(-SI): with clamp terminal• NH-SLS Größen 1, 2, 3: without spike-type terminal, without clamp terminalBusbar mounting• For size 00:• NH-SLS-00/160(-SI) clearance 100 mm, mounting without holes or screw mounting• NH-SLS-00/160-60(-SI) clearance 60 mm, mounting without holes• Sizes 1, 2, 3: clearance 185 mm, mounting without holes or screw mountingWithout fuse monitoring 160 00 NH-SLS-00/160106210Pricesee price listStd. pack0 off160 00 NH-SLS-00/160-60106211250 1 NH-SLS-1/250106212400 2 NH-SLS-2/400106213630 3 NH-SLS-3/630106214With fuse monitoring 160 00 NH-SLS-00/160-SI106215160 00 NH-SLS-00/160-60-SI106216250 1 NH-SLS-1/250-SI106217400 2 NH-SLS-2/400-SI106218630 3 NH-SLS-3/630-SI106219Part no.Article no.Pricesee price listStd. packAdapterSingle adapter 100/185Z-NH-SLS-00-SAD1062200 offDouble adapter 100/185Z-NH-SLS-00-SADD106221Single adapter 100/185 for mounting without holesZ-NH-SLS-00-SAD-KR106222Terminal shroud/size adapter to NH-SLSFor NH-SLS-00/160Z-NH-SLS-KA1062230 offClaw-terminalFor connection at bottomZ-NH-SLS-KRU1062240 offFor connection at topZ-NH-SLS-KRO106225V terminalsUp to 240 mm 2 for stranded sector conductor, up to 300 mm 2 for solid sector conductorFor size 1, 2For size 3Z-NH-SLS-1+2-VAK106226Z-NH-SLS-3-VAK1062270 offFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


OrderingNH fuse mounting accessories16/29http://catalog.moeller.netMoeller HPL0211-2007/2008Z-NH, Z-WASTermination expansion for 2 cable lugsFor size 1, 2For size 3Device carrier with DIN rail for terminals etc.CoverTransformer ratioK NAPart no.Article no.Z-NH-SLS-1+2-AE106239Z-NH-SLS-3-AE106240Z-NH-SLS-1+2+3-GTAB106231Pricesee price listStd. pack0 off0 off<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sLower sectionZ-NH-SLS-1+2+3-GT106230Current transformerNH-SLS-00• Fix on Z-NH-SLS-00-SAD… with fixing clip Z-NH-SLS-00BC.NH-SLS size 1, 2, 3• Swing into the standard rail, no additional space requirement.• Mounting of spike type terminal still possible• Fix <strong>current</strong> transformer cables with fixing clip Z-NH-SLS-1+2+3-BC.150/5 Z-WAS-150/5A-1106232200/5 Z-WAS-200/5A-1106233250/5 Z-WAS-250/5A-1106234300/5 Z-WAS-300/5A-1106235400/5 Z-WAS-400/5A-1106236500/5 Z-WAS-500/5A-1106237600/5 Z-WAS-600/5A-11062380 offFixing clipFixing for <strong>current</strong> transformer on the busbar adapter in185 mm busbar system (size 00)Z-NH-SLS-00-BC1062290 offFixing of the (<strong>current</strong> transformer) cables to the rear ofthe NH rails for sizes 1, 2, 3Z-NH-SLS-1+2+3-BC1062280 offFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616


For Moeller Electric Sales and Support call KMparts.com (866) 595-961616/32EngineeringLet-through characteristics<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>FAZ</strong><strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>FAZ</strong>...Let-through energy JAccording to IEC/EN 608982i dt 10 52[A s] . 8<strong>FAZ</strong>-B<strong>FAZ</strong>-C6421.563 A50 A40 A32 A25 20 A16 A13 A10 A6 A4 ALet-through <strong>current</strong> x DAccording to IEC/EN 60898Î D 10 4[A] 9876543<strong>FAZ</strong>-B<strong>FAZ</strong>-CMoeller HPL0211-2007/2008http://catalog.moeller.net63 A40 A 50 A25 A 32 A20 A16 A13 A10 A6 A4 A3 A10 4863 A2 A21.52 A410 321.510 38<strong>FAZ</strong>-...-B4HI1 A0.5 A51 A0.5 A6430.5 1 1.5 2 3 4 5 6 7 8 9 10 1520.5 1 1.5 2 3 4 5 6 7 8 9 10 15I cc rms [kA]I cc rms [kA]2i dt2[A s] .10 5 8642<strong>FAZ</strong>-D40 A32 A25 A20 A16 A13 A10 A6 AÎ D[A]10 4987654<strong>FAZ</strong>-D40 A32 A25 A20 A16 A13 A10 A6 A1.5310 48261.5410 321.510 385640.5 1 1.5 2 3 4 5 6 7 8 9 10 15I cc rms [kA]20.5 1 1.5 2 3 4 5 6 7 8 9 10 15I cc rms [kA]


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616EngineeringLet-through characteristics16/33http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>sAZ...Let-through energy Ji 2 dt[A 2 s]AZ-C1.510 5864Moeller HPL0211-2007/2008125 A 100 A80 A 63 A50 A40 A32 A25 A20 ALet-through <strong>current</strong> x DÎ D[A]10 486AZ-CAZ80 A100 A 63 A125 A 50 A40 A32 A25 A20 A<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s321.510 41 st half-wave t = 10 ms4382641.53210 31.510 3 550.5 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25I cc rms [kA]0.5 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25I cc rms [kA]∫ i 2 dt[As]1.5AZ-D100 A 80 A 63 A50 AID[A]10 4AZ-D80 A100 A63 A50 A10 588664321.510 4864321.51 st half-wave t = 10 ms4321.510 310 3 550.5 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25I cc rms [kA]0.5 1 1.5 2 3 4 5 6 7 8 9 10 15 20 25I cc rms [kA]


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/34PKNM, Z-DOCombined RCD/MCB <strong>device</strong>sPKNM-...Let-through energy JAccording to IEC/EN 60898i 2 dt 10 5[A 2 s] 86421.5PKNM.../B...EngineeringLet-through characteristics40 A32 A25 A20 A16 A13 A10 ALet-through energy JAccording to IEC/EN 608982i dt 10 52[A s] 8PKNM.../C...6421.5Moeller HPL0211-2007/2008http://catalog.moeller.net40 A32 A25 A20 A16 A13 A10 A10 486 A10 486 A664421.521.510 3810 386644330.5 1 1.5 2 3 4 5 6 7 8 9 10 150.5 1 1.5 2 3 4 5 6 7 8 910 15I cc rms [kA]I cc rms [kA]<strong>Fuse</strong>Z-D0.../S...Let-through <strong>current</strong> characteristic curve<strong>Fuse</strong>Z-D0.../S...Time <strong>current</strong> curve202I P 2 I P 210 32 46 101620253550 63Rated <strong>current</strong> I N in ALet-through <strong>current</strong> I D in kA104210.40.2Possible peak short-<strong>circuit</strong> <strong>current</strong>s With large DC elementWithout DC element63503525201610642Rated <strong>current</strong> I N in AFusing time in s10 210 110 010 -110 -20.10.1 0.2 0.4 1 2 4 10 20 100Short-<strong>circuit</strong> <strong>current</strong> I P in kA10- 3 2 4 10 1 2 4 10 2 2 4 10 3 2 4 10 4Unconditional <strong>current</strong> I P in A


Technical Data<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/35http://catalog.moeller.netMoeller HPL0211-2007/2008<strong>FAZ</strong>, AZ<strong>FAZ</strong> <strong>FAZ</strong>-…-DC <strong>FAZ</strong>-PN AZElectricalStandards IEC/EN 60947-2 IEC/EN 61131-2 IEC/EN 60898 IEC/EN 61131-2IEC/EN 60898Rated operational voltageV AC 230/400 – 230 230/400V DC 48 (per pole) 250 (per pole) 48 (per pole) 60 (per pole)Rated switching capacity kA 15 10 6 25Operational switching capacity kA 7.5 – – 20Characteristic B, C, D C B, C Similar: D, CMax. back-up fuse A gL/gG 125 100 100 200Selectivity Class 3 3 3 Compliant with Class 3Lifespan Operations > 10000 > 10000 > 4000 > 10000Direction of incoming supply As required Polarity dependent As required As required<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sMechanicalStandard front dimension mm 45Enclosure height mm 80 80 80 90Terminal protectionFinger and back-of-hand proof to BGV A2Mounting width per pole mm 17.5 17.5 17.5 27MountingIEC/EN 60715 top-hat railProtection typeIP20, IP40 (when fitted)Terminals top and bottom Twin-purpose terminals Lift terminalsTerminal capacitiesSolid mm 2 1 x 25 1 x 25 1 x 16 2.5 … 50flexible mm 2 2 x 10 2 x 10 – –Thickness of busbar material mm 0.8 … 2 0.8 … 2 – –Mounting position As required – –For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/36Technical Data<strong>Residual</strong> <strong>current</strong> <strong>device</strong>PKNM, <strong>FI</strong>M, AZ<strong>FI</strong>MP, <strong>FI</strong>Moeller HPL0211-2007/2008http://catalog.moeller.netPKNM <strong>FI</strong>M AZ<strong>FI</strong>MP <strong>FI</strong> F 100 A <strong>FI</strong> 125 A and type B<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sElectricalStandards IEC/EN 61009 IEC/EN 61009 IEC/EN 61131-2 IEC/EN 61008 IEC/EN 61008Tripping A 250 (8/20m) non-delayed surge resistent Non-delayed, SRated operational voltage U e V AC 230 230/400 230/400 230/400 230/400Limit values of the operating V AC 196 … 253 196 … 440 196 … 440 184 … 440 184 … 440voltageRated frequency f Hz 50Rated fault <strong>current</strong>s I Dn mA 30, 300 30, 300 30, 300 30, 100, 300, 500 30, 100, 300, 500Rated non-tripping <strong>current</strong> 0.5 x I dn 0.5 x I dn 0.5 x I dn 0.5 x I dn 0.5 x I dnRated fault switchingcapacityI Dm A In = 16…40 A: 500In = 63 A: 630In = 80 A: 800In = 100A: 1000In = 125 A: 1250for Type B:60. 80 A: 80040 A: 500125 A: 1250230 V kA 6 – – – –400 V kA 3 – – – –Sensitivity DC and pulsed <strong>current</strong> Pulsed <strong>current</strong> andAC/DCRated switching capacity cn I kA 10 As fitted <strong>FAZ</strong> As fitted AZ 10 10Operational switchingcapacityRated ultimate short-<strong>circuit</strong>breaking capacityI cs kA As fitted <strong>FAZ</strong>I cu As fitted AZ As fitted AZRated short-<strong>circuit</strong> switching= I cucapacityRated <strong>current</strong> I e A 6 … 40 40, 63 80, 125 16 … 100 40 … 125Rated impulse withstand U imp kV 6 (1.2/50 ms) 4 (1.2/50 ms) 6 6voltageCharacteristicB, CMaximum max. as short<strong>circuit</strong>protective <strong>device</strong>A gL 100 I n = 16…63 A: 63I n = 80 A: 80I n = 100 A: 100I n = 125 A: 125for Type B:I n F 80: 100I n = 125: 125Selectivity Class 3LifespanElectrical Operations > 4000 > – > 1500 > 4000 > 2000Mechanical Operations > – > – > 10000 > 20000 > 5000MechanicalStandard front dimension mm 45 45 45 45 45Enclosure height mm 80 90 90 80 85Terminal protection Protection against electric shock to IEC 536Mounting width mm 35 (2 space units) 70 (2-pole), 125 (4-pole)MountingPermanent screwconnection with<strong>FAZ</strong>95 (5.5 space unit) 35 (2 space unit), 70(4 space units)Screwed on to AZ(2- to 4-pole)Top-hat rail IEC/EN60715Degree of protectionSwitch IP 20Integrated IP40 IP40 IP40 IP40 IP40Terminals top and bottomTwin-purposeterminalsLift terminals Lift terminals Twin-purposeterminals70 (4 space unit)Top-hat rail IEC/EN60715Twin-purposeterminalsTerminal capacitiesSolid mm 2 1 x 25 1 x (1 – 25) 2.5 … 50 1.5 … 35 1.5 … 50flexible mm 2 1 x (0.75 – 16) 2 x 16 2 x (1.5 – 16)Thickness of busbar material mm 0.8 … 2 0.8 … 2 0.8 … 2 0.8 … 2Admissible ambient°C -25 … +40 -25 … +40 -25 … +40 -25 … +40 -25 … +40temperature rangeClimatic proofing IEC/EN 61009 IEC/EN 61009 IEC/EN 60068-2 IEC/EN 61008 IEC/EN 61008For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


Technical DataAuxiliary contacts, voltage releases16/37http://catalog.moeller.netMoeller HPL0211-2007/2008<strong>FAZ</strong>-XHIN, <strong>FAZ</strong>-X…<strong>FAZ</strong>-XHIN11 <strong>FAZ</strong>-XHINW1 <strong>FAZ</strong>-XAM002 <strong>FAZ</strong>-XAA-C <strong>FAZ</strong>-XUAElectricalRated operational voltage U e V AC 250 250 250 – 115, 230, 400Contact function 1 NO + 1 NC 1 W 2 C/O – –Voltage range V AC – – – 12 … 110 –110 … 415Closing threshold x U n – – – – 0.8Tripping threshold x U – – – – 0.5Rated frequency f Hz 50/60 50/60 50/60 50/60 50/60Rated <strong>current</strong> I e A 6 6 4 – –Conventional free air thermal <strong>current</strong> I th A 6 6 4 – –Rated operational <strong>current</strong>AC-12 e I A 3 (250 V AC) 3 (250 V AC) 3 (250 V AC) – –AC-15 e I A 2 (250 V AC) 2 (250 V AC) 2 (250 V AC) – –DC-13 e I A 0.5 (110 V DC) 0.5 (110 V DC) 0.5 (110 V DC) – –Rated insulation voltage U i V AC 250 250 250 – –Minimum operating voltage per contact U min V DC 5 5 5 – –Rated impulse withstand voltage (1.2/50 ms) U imp kV 2.5 2.5 2.5 – –Rated conditional short-<strong>circuit</strong> <strong>current</strong>sc I kA 1 1 1 – –With 6 A back-up fuseMax. admissible back-up fuse A gL 6 6 4<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sMechanicalStandard front dimension mm 45 45 45 45 45Enclosure height mm 80 80 80 80 80Mounting width mm 8.8 (0.5 space 8.8 (0.5 space 8.8 (0.5 space 17.5 (1 space 17.5 (1 spaceMountingmax. 2 x onMCBmax. 2 x onMCBOn MCB IEC/EN 60715top-hat railDegree of protectionIntegratedIP40Terminal protection Protection against electric shock to IEC 536Terminals Lift terminals Lift terminals Lift terminals Twin-purposeterminalsIEC/EN 60715top-hat railTwin-purposeterminalsTerminal capacitiesSolid mm 2 0.5 … 2.5 0.5 … 2.5 0.5 … 2.5 1 … 2.5 2 x (1 – 2.5)flexible mm 2 0.5 … 2.5 0.5 … 2.5 0.5 … 2.5 1 … 2.5 2 x (1 – 2.5)Tightening torque of terminal screws Nm F 1.2 F 1.2 0.8 … 1.0 2.4 0.8For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/38Technical DataAuxiliary contacts, voltage releasesAZ-X…, <strong>FI</strong>-X…Moeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sAZ-XHI11 AZ-XAA <strong>FI</strong>-XHI11 F 100 A <strong>FI</strong>PA-XAM011125 A RCCB andtype BElectricalContact function 1 M + 1 B 1 M + 1 B 1 C/O + 1 BVoltage range V AC 12 … 110110 … 415Voltage range V DC 12 … 60110 … 220Min. operating voltage U e V/mA 24/50 24/50Rated operational <strong>current</strong>AC–-14230 V I e A 6 6 6AC–-13250 V I e A 6 – 6 –400 V I e A 2 – 2 –DC–1124 V I e A 4 – – 1DC-1360 V I e A 4 – 4 –110 V I e A 2 – 2 –230 V I e A 0.5 – 0.5 –Rated insulation voltage U i V AC 440 440 440 440Minimum operating voltage per contact U min V DCRated impulse withstand voltage (1.2/50 ms) U imp kVRated conditional short-<strong>circuit</strong> <strong>current</strong> With 6 A sc I kA – – – –back-up fuseMax. admissible back-up fuse A gL 6 Inherently short<strong>circuit</strong>-proof6 6LifespanMechanical Operations > 6000 > 4000 > 6000 –Inrush <strong>current</strong>AC A – 38 – –Pick up time AC ms – 2.1 – –DC A – 34 – –Pick up time DC ms – 2 – –MechanicalStandard front dimension mm 45 45 45 45Enclosure height mm 90 90 90 90Mounting width mm 8.8 (0.5 space unit) 17.5 (1 space unit) 8.8 (0.5 space unit) 8.8 (0.5 space unit)MountingIEC/EN 60715 top-hat railDegree of protectionIntegratedIP40Switch IP 20Terminal capacitiesSolid mm 2 1 x (1 – 25)2 x (1 – 4)flexible mm 2 1 x (1 – 25)2 x (1 – 4)1 x (1 – 25)2 x (1 – 4)1 x (1 – 25)2 x (1 – 4)2 x (0.5 – 2.5)1 x (0.5 – 2.5)2 x (0.5 – 2.5)1 x (0.5 – 2.5)Tightening torque of terminal screws Nm 0.8 3 0.8 0.82.52.5For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


Technical DataRemote switching module, fuse material16/39http://catalog.moeller.netMoeller HPL0211-2007/2008<strong>FAZ</strong>-<strong>FI</strong>P, D01-S, D02-S<strong>FAZ</strong>/<strong>FI</strong>P-XAWM<strong>FAZ</strong>/<strong>FI</strong>P-XDWMElectricalOperational voltage rangeV AC 220 … 240V DC 48Rated frequency f Hz 50/60Relay output for alarm, 250 V AC, potential-free A 5 5FunctionAutomatic controlFunction selectorAutomatic 5 x, OFF/RESETMechanicalStandard front dimension mm 45 45Enclosure height mm 80 80Mounting width mm 70 70Mounting Top-hat rail to IEC/EN 60715Degree of protectionIntegratedIP40Terminal protection Protection against electric shock to IEC 536TerminalsLift terminalsTerminal capacitiesSolid mm 2 2 x 1.51 x 2.5flexible mm 2 2 x 1.51 x 2.52 x 1.51 x 2.52 x 1.51 x 2.5<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sElectricalNumber of polesD01-S0/ D02-S0/ D02-S/63/3-RSRated operating voltage U e V AC 400 400 400V DC 250 250Rated short-<strong>circuit</strong> <strong>current</strong> tested with links I e kA 50 (AC) / 8 (DC) 50 (AC) / 8 (DC) 50Rated frequency f Hz 40…60Rated operational <strong>current</strong> I e A 16 63 63Conventional thermal <strong>current</strong> with fuse links I th A 63Rated operating modeUninterrupted operationOvervoltage categoryIIIUtilization categoryAC 23 BRated impulse withstand voltage U imp kV – – 8Current heat loss per contact at I e W – – 0.5Power lossHeat dissipation per contact with fuse link at I e W – – 7.51P3P1P3P3PMax. permissible heat losses of the fuse links W 5.5Utilization category gG (gL) gG (gL)MechanicalStandard front dimension mm 45 45 –Enclosure height mm 68 68 212Mounting width mm 27 (per pole) 27 (per pole) 36Weight g 1P 763P 2301P 763P 230Electrical hoist E14 E18 E18Mounting Quick attachment for top-hat rail IEC/EN 60715 Busbar with 60 mmclearanceDegree of IntegratedIP30protectionTerminals Double function terminals Lift terminalsTerminal Solid mm 2 1.5 … 35 1.5 … 35 1.5 … 25 CucapacitiesTemperature range °C -25 … +55Specified tightening torque for terminal screws Nm 2.5 … 3 2.5 … 3 max. 2.6Pollution degree 3Creepage resistance CTI 200 CTI 200260For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/40Technical Data<strong>Fuse</strong> materialZ-SLS, Z-SLKMoeller HPL0211-2007/2008Z-SLS/NE0Zhttp://catalog.moeller.netZ-SLK/NE0Z<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sElectricalNumber of polesRated operational voltage V DC 1P up to 110V / 2P up to 220VRated operating voltage U e V AC 400 400Rated operational <strong>current</strong> I e A 63 63Rated uninterrupted <strong>current</strong> I u A 63 63Rated short-<strong>circuit</strong> making capacity 50 kAeff 50 kAeffN/O5A/250VSwitching category AC 22 B, DC 21 B AC 22 B, DC 21 BOvervoltage category IV IVRated impulse withstand voltage U imp kV 6 6Current heat loss per contact at I e W 0.5 0.5Power lossHeat dissipation per contact with fuse link at I e W 7.5 7.51P1P+N2P3P3P+N1P1P+N2P3P3P+NRelay section electricalOperating voltage range V AC 24 … 240Operational voltage tolerance g10%Power consumption VA – 5Frequency Hz 50…60Function displayMains: 1 LEDFault: 1 LEDDuty factor % 100Response delay/On-delay ms – 100Recovery time t W ms – Approx.100Relay contacts2 changeover contacts,5A/250VOvervoltage categoryIIIAuxiliary contactsRated impulse withstand voltage U imp kV – 4MechanicalStandard front dimension mm 45 45Enclosure height mm 86 86Mounting width mm 27/per pole (1.5 SU) 27/per pole (1.5 SU) + 27Weight g 1P 1131P+N 2252P 2243P 4503P+N 4721P 2242P 3453P 4503P+N 472Mounting Quick attachment for top-hat rail IEC/EN 60715Integrated IP20 IP20Terminals Lift terminals Lift terminalsTerminal capacitiesSolid mm 2 1.5 … 35 1.5 … 35Temperature range °C -25 … +60 -25 … +60Flammability classification to EN 60730 V0, glow-wire test 960°CSpecified tightening torque for terminal screws max. 4.5 max. 4.5Pollution degree 3 3Creepage resistance CTI 600 CTI 600Relay section mechanicalTerminals Lift terminals Lift terminalsTerminal capacitiesSolid mm 2 0.14…4flexible mm 2 0.14…2.5Specified tightening torque for terminal screws0.5…0.7For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


Technical Data<strong>Fuse</strong> switch-disconnectors, safety material16/41http://catalog.moeller.netMoeller HPL0211-2007/2008VLC, Z-D0…, Z-SLS…VLC14VLC22ElectricalNumber of polesRated operating voltage U e V AC 690 690Rated operational <strong>current</strong> I e A 50 100Rated conditional short-<strong>circuit</strong> <strong>current</strong> I e kA 100 100Rated frequency f Hz 50 50Utilization category AC 22 B AC 21 BRated impulse withstand voltage U imp kV 8 8<strong>Fuse</strong> W gG: 5, aM: 3 gG: 9.5, aM: 71P1P+N2P3P3P+N1P1P+N2P3P3P+N<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sMechanicalStandard front dimension mm 45 45Enclosure height mm 94 121Mounting width mm 27/per pole 36/per poleWeight g 1P 1001P+N 2222P 2013P 3083P+N 4371P 1601P+N 3552P 3103P 4803P+N 680Mounting Quick attachment for top-hat rail IEC/EN 60715Degree of protectionIntegratedIP20TerminalsLift terminalsTerminal capacitiesSolid mm 2 1.5…10 2.5…35Temperature range °C -25 … +60 -25 … +60Specified tightening torque for terminal screwsTightening torque Nm max. 2 max. 2.5Pollution degree 1 1Creepage resistance CTI 400 CTI 400Z-D01/SEZ-D02/SEElectricalRated operating voltage U e V AC 400 400V DC 220 220Utilization category gG (gL) gG (gL)Rated frequency f Hz 45…65 45…65Rated insulation voltage U i V 2500 2500Rated short-<strong>circuit</strong> switching capacity50 kA (AC)8 kA (DC)50 kA (AC)8 kA (DC)Z-SLS/B Z-SLS/B24 Z-SLS/TR-SETElectricalRated operational voltage V DC 24Rated operating voltage U e V AC 60 … 400 24 400Utilization category gG (gL) gG (gL)Test voltage kV 5 5 5Rated uninterrupted <strong>current</strong> I u A – – 63For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/42Technical DataNH fuse switch-disconnectorLTS…, GST…Moeller HPL0211-2007/2008http://catalog.moeller.netLTS-100/C00/3-R GST…00-160 GST…1 GST…2 GST…3<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sGeneralStandards IEC/EN 60947-3Climatic proofing Damp heat, constant, to IEC 60068-2-78Damp heat, cyclical, to IEC 60068-2-30Ambient temperature °C -25 … +55 -25 … +55 -25 … +55 -25 … +55 -25 … +55Altitude m 2000 2000 2000 2000 2000Mounting positionVertical, horizontalOvervoltage category/pollution degree III/3 III/3 III/3 III/3 III/3Degree of protection, from the frontOperational state IP20 IP20 IP20 IP20 IP20Front cover open IP10 IP10 IP10 IP10 IP10Direction of incoming supplyAs requiredWeight kg 0.57 0.72 GSTA0.93 GST2.5 GSTA4.4 GST3.3 GSTA5.3 GST4.6 GSTA6.6 GSTContactsRated operational voltage U e V AC 500 500690Rated operational voltage Ue V DC 220 220440Rated operational <strong>current</strong> I e A 100 160100Rated frequency Hz 40 – 60 40 – 60 40 – 60 40 – 60 40 – 60Rated conditional short-<strong>circuit</strong> <strong>current</strong> AC kA rms 50 50 50 50 50Rated conditional short<strong>circuit</strong> <strong>current</strong> DC kA rms 25 25 25 25 25Utilization category AC22BRated making capacity A 300 480300Rated breaking capacity A 300 480300Utilization category DC21BRated making capacity A 400 150 300 475 750Rated breaking capacity A 400 150 300 475 750Lifespan, electrical Switching operations 300 300 200 200 200Lifespan, mechanical Switching operations 1700 1700 1400 800 800Heat dissipation at I th AC, without NH-SE W 11.5 6.92.7Heat dissipation at I th DC, without NH-SE W 7.7 4.61.8Rated insulation voltage U i V AC 500 750 750 750 750Max. fuseSize NH000 NH00 NH1 NH2 NH3Max. rated <strong>current</strong> gG/g A 100 160 250 400 630Max. admissible heat dissipation NH-SE Pv W 7.5 12 23 34 4850069022044025020075060075060012.98.38.65.5500690220440400315120094512009452716.71811.250069022044063050018901500189015005232.834.721.8Terminal capacityBox terminalStranded mm 2 1.5 – 50 1.5 – 70 – – –Copper strip Number of segments x width x thickness mm 6 x 9 x 0.8 6 x 9 x 0.8Tightening torque Nm 2.6 2.6Box terminalStranded – – 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Copper strip mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Tightening torque mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Tightening torque Nm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Box terminalStranded copper mm 2 1.5 … 70 25 … 150 25 … 240 25 … 300Copper braid Number of segments x width x thickness mm 6 x 16 x 0.8 10 x 16 x 0.8 11 x 21 x 1Tightening torque Nm 9.5 23 23Clamp-type terminalStranded aluminium/copper mm 2 70 … 150 120 … 240 120 … 300Tightening torque Nm 4.5 11 11Double clamp-type terminalStranded aluminium/copper mm 2 2 x (70 …95)2 x (120 …150)Tightening torque Nm 4.5 11 112 x (120 …240)For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


Technical dataLow-voltage h.b.c. switch-fuse units16/43http://catalog.moeller.netMoeller HPL0211-2007/2008NH-SLSNH-SLS-00/160(-60) NH-SLS-1/250 NH-SLS-2/400 NH-SLS-3/630ElectricalTechnical data to IEC/EN 60947-3Size 00 1 2 3Number of poles/phases 3 3 3 3Conventional free-air <strong>current</strong>with low-voltage h.b.c fuse links I th A 160 250 400 630Max. permissible rated heat dissipationof the low-voltage h.b.c. fuse links W 12 23 34 48Utilization category AC 23 BRated operational voltage U e V AC 400 500 500 500Rated operational <strong>current</strong> I e A 160 250 400 630Rated conditional short-<strong>circuit</strong> <strong>current</strong>with fuse protection kA 50 100 100 100Utilization category AC 22 B, AC 21 BRated operational voltage U e V AC 690 690 690 690Rated operational <strong>current</strong> I e A 160 250 400 630Rated conditional short-<strong>circuit</strong> <strong>current</strong>with fuse protection kA 50 100 100 100Rated insulation voltage U i V 1000 1000 1000 1000Overvoltage category III III III IIIRated impulse withstand voltage U imp kV 8 12 12 12Rated frequency Hz 50…60 50…60 50…60 50…60Rated operating mode Uninterrupted operation 1)Power consumption without low-voltage h.b.c. fuse links 20 W at 160 A 30 W at 250 A 67 W at 400 A 116 W at 630 A<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sMechanicalMounting on busbarsSpike terminal for busbar thickness mm 10 (5 … 10) 10 10 10Screw for busbar thickness mm 5 … 10M8 (without screws)5 … 10M125 … 10M125 … 10M12Standard connection screw M8 M10 M10 M12Cable lug – Cu conductor according to rated <strong>current</strong>s tomm 2 1 x 70 120 240 2 x 185IEC/EN 60947-1Current busbar max. width mm 20 30 30 30Ambient temperature range °C –5 … +40 –5 … +40 –5 … +40 –5 … +40Degree of protection IP30 IP30 IP30 IP30Pollution degree 3 3 3 3Notes1) With uninterrupted operation of several adjaced <strong>device</strong>s the rated diversity factor to EN 60439-1, Tabel 1 must be observed.The distance to earthed parts must be at least 50/100 mm at the top and 25/50 mm on the sides with sizes 00/1-3.For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/44Technical dataLow-voltage h.b.c. switch-fuse unitsNH-SLS…-SIMoeller HPL0211-2007/2008http://catalog.moeller.netNH-SLS-00/160(-60)-SI NH-SLS-1/250-SI NH-SLS-2/400-SI NH-SLS-3/630-SI<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sElectricalTechnical data to IEC/EN 60947-3Size 00 1 2 3Number of poles/phases 3 3 3 3Conventional free-air <strong>current</strong>with low-voltage h.b.c fuse links I th A 160 250 400 630Max. permissible rated heat dissipationof the low-voltage h.b.c. fuse links W 12 23 34 48Utilization categories AC 23 B, AC 22 B, AC 21 BRated operational voltage U e V AC 400 400 400 400Rated operational <strong>current</strong> I e A 160 250 400 630Rated conditional short-<strong>circuit</strong> <strong>current</strong>with fuse protection kA 50 100 100 100Rated insulation voltage U i V 400 400 400 400Rated impulse withstand voltage U imp kV 4 4 4 4Rated frequency Hz 50…60 50…60 50…60 50…60Rated operating mode Uninterrupted operation 1)Overvoltage category III III III IIIPower consumption without low-voltage h.b.c. fuselinks20 W at 160 A 30 W at 250 A 67 W at 400 A 116 W at 630 AMechanicalMounting on busbarsSpike terminal for busbar thickness mm 10 (5…10) 10 10 10Screw for busbar thickness mm 5…10M8 (without screws)Standard connection screw M8 M10 M10 M12Cable lug – Cu conductor according to rated <strong>current</strong>smm 2 1 x 70 120 240 2 x 185to IEC/EN 60947-1Current busbar max. width mm 20 30 30 30Ambient temperature range °C –5…+40 –5…+40 –5…+40 –5…+40Degree of protection IP30 IP30 IP30 IP30Pollution degree 3 3 3 3Electronic fuse monitoringElectricalRated voltage V AC 3 x 400Rated frequency Hz 50…60Rated insulation voltage U i V 400Overvoltage categoryIIIRated impulse withstand voltage U imp kV 4Relay contacts2 changeover contacts 1 A, 250 VMechanicalTerminalsLift terminalsTerminal cross-sectionSolid mm 2 2 x 2.5Flexible mm 2 2 x 1.5Tightening torque of terminal screws Nm 0.85…10M125…10M125…10M12Notes1) With uninterrupted operation of several adjaced <strong>device</strong>s the rated diversity factor to EN 60439-1, Tabel 1 must be observed.The distance to earthed parts must be at least 50/100 mm at the top and 25/50 mm on the sides with sizes 00/1-3.For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


Technical DataLV h.b.c. fuse bases16/45http://catalog.moeller.netMoeller HPL0211-2007/2008GS…, GSU…GS00-160 GSU1 GSU2 GSU3GeneralStandards IEC/EN 60 269-2-1;VDE0636-201Climatic proofing Damp heat, constant, to IEC 60068-2-78Damp heat, cyclical, to IEC 60068-2-30Ambient temperature °C -25 … +55 -25 ... +55 -25 ... +55 -25 ... +55Altitude m 2000 2000 2000 2000Mounting position Vertical, horizontal Vertical, horizontal Vertical, horizontal Vertical, horizontalOvervoltage category/pollution degree III/3 III/3 III/3 III/3Degree of protection, from the frontOperational state IP00 IP00 IP00 IP00Direction of incoming supply As required As required As required As requiredWeight kg 0.4 1.7 2.1 2.7<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sContactsRated operational voltage U e V AC 690 690 690 690Rated operational voltage Ue V DC 440 440 440 440Rated operational <strong>current</strong> I e A 160 250 400 630Rated frequency Hz 40 – 60 40 – 60 40 – 60 40 – 60Heat dissipation at I th AC, without NH-SE W 6.9 12.9 27 52Heat dissipation at I th DC, without NH-SE W 4.6 8.6 18 34.7Rated insulation voltage U i V AC 750 750 750 750Max. fuseSize NH00 NH1 NH2 NH3Max. rated <strong>current</strong> gG/g A 160 250 400 630Max. admissible heat dissipation NH-SE Pv W 12 23 34 48Terminal capacityBox terminalStranded mm 2 – – – –Copper strip Number of segments x mmwidth x thicknessTightening torqueNmBox terminalStranded – 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Copper strip mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Tightening torque mm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Tightening torque Nm 6 x 9 x 0.8 6 x 9 x 0.8 6 x 9 x 0.8Box terminalStranded copper mm 2 1.5 … 70 25 – 150 25 – 240 25 – 300Copper braid Number of segments x mm 6 x 9 x 0.8 6 x 16 x 0.8 10 x 16 x 0.8 11 x 21 x 1width x thicknessTightening torque Nm 2.6 9.5 23 23Clamp-type terminalStranded aluminium/copper mm 2 70 – 150 120 – 240 120 – 300Tightening torque Nm 4.5 11 11Double clamp-type terminalStranded aluminium/copper mm 2 2 x 70 … 95 2 x 120 … 150 2 x 120 … 240Tightening torque Nm 4.5 11 11For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


16/46Dimensions<strong>Miniature</strong> Circuit-Breakers, <strong>Residual</strong>-Current Circuit-Breakers<strong>FAZ</strong>, AZ, <strong>FI</strong>M, PKNM, AZ<strong>FI</strong>MMoeller HPL0211-2007/2008http://catalog.moeller.net<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>FAZ</strong>...17.535<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>sAZ...52.570805.54460458<strong>FAZ</strong>-PN-...17.5805.544609.5451590452754811085.54460<strong>Residual</strong>-<strong>current</strong> protective modulesCombined RCD/MCB <strong>device</strong>s<strong>FI</strong>M-...PKNM-...9.59.59090458045355.544701255.5446060<strong>Residual</strong>-<strong>current</strong> protective modulesAZ<strong>FI</strong>M...90904594.55494.51085.54460<strong>Residual</strong> <strong>current</strong> <strong>device</strong><strong>FI</strong>-...10.59.58545804535705.54460726314460For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


For Moeller Electric Sales and Support call KMparts.com (866) 595-9616http://catalog.moeller.netAuxiliary contacts<strong>FAZ</strong>-XHIN11808.85.54460DimensionsShunt releases, undervoltage releases, restarting moduleMoeller HPL0211-2007/200845<strong>FAZ</strong>-XAM002AZ-XHI11 <strong>FI</strong>P-XHI11 <strong>FI</strong>PA-XAM011808.85.54460<strong>FAZ</strong>-X, AZ-X, <strong>FAZ</strong>/<strong>FI</strong>P, <strong>FI</strong>P(A), Z-FW4516/4790<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s45804580854595.544608.85.52344608.85.5 4460Shunt releases Shunt releases Undervoltage releases<strong>FAZ</strong>-XAA-C... AZ-XAA... <strong>FAZ</strong>-XUA...80459045804517.55.5 30.5 4.5 9.626.2 44602739.15.544 156017.55.54460Restarting module<strong>FAZ</strong>/<strong>FI</strong>P-...Z-FW-LPZ-FW-LPD11.88045804518.4705.544 11.8607018.4705.544FT70Z-FW-MO80453544FT


16/48DimensionsBusbars, fuse bases, fuse switch-disconnector<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sBusbarsEVG-16/...Extension terminalsZV-...-80A-...6517<strong>Fuse</strong> baseD01-SO/...D02-SO/...a46EVG-16, ZV, D0…-S, Z-SLS, Z-SLKc1.5b1bMoeller HPL0211-2007/2008http://catalog.moeller.netType a b b1 cEVG-16/1PHAS/2MODUL 33 25.9 14 3.4EVG-16/1PHAS/6MODUL 105 25.9 14 3.4EVG-16/1PHAS/12MODUL 210 25.9 14 3.4EVG-16/2PHAS/4MODUL 75.5 30.9 19 7.3EVG-16/2PHAS/6MODUL 105 30.9 19 7.3EVG-16/2PHAS/12MODUL 209.5 30.9 19 7.3EVG-16/3PHAS/6MODUL 102.5 30.9 19 10.3EVG-16/3PHAS/9MODUL 156 30.9 19 10.3EVG-16/3PHAS/12MODUL 209.5 30.9 19 10.3EVG-16/3PHAS/16MODUL 285 30.9 19 10.3EVG-16/3PHAS/20MODUL 353 30.9 19 10.3EVG-16/4PHAS/8MODUL 138 30.9 19 13.3EVG-16/4PHAS/12MODUL 209.5 30.9 19 13.3EVG-16/3PHAS/N/5MODUL/LS 156 30.9 19 10.3EVG-16/3PHAS/N/8MODUL/LS 209.5 30.9 19 10.3EVG-16/1PHAS/2MODUL/HI 60 25.9 14 3.4EVG-16/1PHAS/6MODUL/HI 156.5 25.9 14 3.4EVG-16/1PHAS/9MODUL/HI 237 25.9 14 3.4EVG-16/2PHAS/4MODUL/HI 75.5 30.9 19 7.3EVG-16/2PHAS/6MODUL/HI 120 30.9 19 7.3EVG-16/2PHAS/10MODUL/HI 209.5 30.9 19 7.3EVG-16/3PHAS/6MODUL/HI 115 30.9 19 10.3EVG-16/3PHAS/12MODUL/HI 237 30.9 19 10.3EVG-16/3x 1PHAS/6MODUL/HI 152 30.9 19 10.3EVG-16/3x 1PHAS/8MODUL/HI 209.5 30.9 19 10.3EVG-16/3x 1PHAS/9MODUL/HI 229 30.9 19 10.3Busbar mounting switch-disconnectorD02-S/63/3-RS21325 – 101942126068604520 – 3031.527 816556036 77fuse switch-disconnectorWith fuse monitoring, emptyStandard, emptyZ-SLS/NEOZ/...Z-SLK/NEOZ/...8645864527 466027 27 46607070For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


http://catalog.moeller.netMoeller HPL0211-2007/2008<strong>Fuse</strong> switch-disconnectors, emptyVLC14...27 5.2 42.554.670459094Dimensions<strong>Fuse</strong> base, fuse switch-disconnectorVLC22...36 6.2 42.554.670VLC, GS…, GST…4511712116/49<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>sLow-voltage h.b.c. fuse baseGSU1 GSU2 GSU3 GS00-160rst7o 7.53025581362550abco 5.5d32.5 32.588o 5.5o 10.5104giqhgefoType a b c d e f g h i o q r s tGSU1 175 200 248 M10 35 2 66 200 34 107 191 164 150 100GSU2 200 225 248 M10 35 2 66 200 34 115 191 164 150 100GSU3 210 250 273 M10 35 3 84 254 40 132.5 245 200 186 136Low-voltage h.b.c. fuse switch-disconnectors1 pole 3 poleGSTA00-160-1P GSTA00-160 GSTA1 GSTA2 GSTA3135430220.5270o 10.599130.596147Part no. a a1 b b1 b2 b3 b4 b5 c c3 d e fGSTA00-160-1P 49 - 169 79 149 120 - - 86.5 - 7 - -GSTA00-160 106 66 169 79 149 120 25 26 86.5 197 7 50 -GSTA1 182 116 250 115 230 184 30 23 111 294 5.5 150 -GSTA2 208 132 275 128 256 217 30 19,5 125 330.5 5.5 175 25GSTA3 254 164 283 135 270 238 30 16 142 348 5.5 200 50For Moeller Electric Sales and Support call KMparts.com (866) 595-9616


fFor Moeller Electric Sales and Support call KMparts.com (866) 595-9616<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s16/50Dimensions<strong>Fuse</strong> bases, fuse switch-disconnectorsGS00160, GST(A), LTSLow-voltage h.b.c. fuse switch-disconnectorsDrilling dimensionsGSTA00-160-1P GSTA2GSTA1GSTA325ed50fedMoeller HPL0211-2007/2008LTS-100/C00/3-R19460 6012 – 30 31.563 5 – 1031.5 3260101http://catalog.moeller.netPart no. a a1 b b1 b2 b3 b4 b5 c c3 d e fGSTA00-160-1P 49 - 169 79 149 120 - - 86.5 - 7 - -GSTA00-160 106 66 169 79 149 120 25 26 86.5 197 7 50 -GSTA1 182 116 250 115 230 184 30 23 111 294 5.5 150 -GSTA2 208 132 275 128 256 217 30 19,5 125 330.5 5.5 175 25GSTA3 254 164 283 135 270 238 30 16 142 348 5.5 200 50GST00-160-40-60-AOUG0V40101G0/19540/50/6015822940/50/6015119412/20/30412112106.4GU/19533 3331105.5GUV60135.../ES005 – 15 3235GST1-...GST2-...l1l.../A0ecF 30h 60 60.../ES00gbkk F 10 i.../AUajdPart no. a b c d e f g h i j k l l1GST1-… 184 230 247 70 121 16.5 115 42 27 55 58 151 161GST2-… 210 256 272 83 135 16.5 128 53 27 55 66 165 175


http://catalog.moeller.netMoeller HPL0211-2007/2008Low-voltage h.b.c. fuse switch-disconnectorsGST3-...430Dimensions<strong>Fuse</strong> switch-disconnectors, NH fuse switch-disconnectors141 60 6020 – 30216 134350GST, NH-SLS16/5180<strong>Miniature</strong> <strong>circuit</strong>-<strong>breaker</strong>s<strong>Residual</strong>-<strong>current</strong> <strong>circuit</strong>-<strong>breaker</strong>s82 822545 – 10 54117119.5170.5NH-SLS-00/160NH-SLS-00/160-SINH-SLS-00/160-60NH-SLS-00/160-60-SI120136F 238455a 61026.526.533 335.5289455a 61026.526.533 335.528950 31 67.584.550 15 83.5100.5NH-SLS-1/250NH-SLS-1/250-SINH-SLS-2/40099NH-SLS-2/400-SINH-SLS-3/630NH-SLS-3/630-SI197148145a NH-SLS…-SI(with safety monitoring)764a 908322 258580610F 45714.55716.55058For Moeller Electric Sales and Support call KMparts.com (866) 595-9616