Modular electrical linear drives OSP-E - parker-origa.com

Modular electrical linear drives OSP-E - parker-origa.com Modular electrical linear drives OSP-E - parker-origa.com

operatorserv.ro
from operatorserv.ro More from this publisher
12.07.2015 Views

Modular electrical linear drives OSP-E9 Accessories9.1 Multi-axle systemWith the use of Parker-Origa adapter plates, profile attachments and/or intermediate drive shafts, the connectionof linear drives in a multi-axle arrangement is possible.Further information on this subject can be found in the OSP-E catalogue.9.2 Linear guidesThe Origa System Plus–OSP–offers the possibility of adapting various types of guides to the linear drive.Further information on this subject is available in the OSP-E catalogue or in the separate operating instructionsfor guides and brakes.9.3 Mountings and sensorsWith the help of the comprehensive range of Parker-Origa accessories for mounting components, the lineardrives can be secured depending on the surrounding conditions.With the Parker-Origa sensors, a non-contact scanning of the linear drives is achieved at end and/or intermediatepositions.Further information on this subject can be found in the OSP-E catalogue.9.4 Couplingbox and coupling9.4.1 OSP-E belt drive• Push the location ring (6) over the drive shaft (7) until this is positioned in the cover of the drive. Observeand ensure correct location of the location ring !• Connect the coupling (5) with the drive shaft (7) in such a way that there is a defined clearance “X”, asstated in the table• or make sure that the hex screw at the motor end of the coupling is accessible through the window in thecoupling housing (4).• Secure coupling (5) to the drive shaft (7).• Push the coupling housing (4) onto the location ring (6).Size Dimension „X“ Dimension „Y“ Tightening torqueOSP-E20BHD 6,4 mm 2 mm 10,5 NmOSP-E20BV 6,4 mm 2 mm 10,5 NmOSP-E25BV 13 mm 2 mm 10,5 NmOSP-E25B 14 mm 1 mm 0,76 NmY5 7OSP-E32B 10 mm 1,5 mm 1,34 NmOSP-E50B 5 mm 2 mm 10,5 Nm34

EN• Place location ring (3) into the coupling housing. Observe and ensure correct location of the location ring !1 23 4• Fix-position the motor flange (2) at the coupling housing (4).• Secure the coupling unit at the linear drive with the screws (1).• Tightly screw the motor to the motor flange (2).• Tighten the screws of the coupling through the window of the coupling case (4). Use a screw driver to assistin the alignment of the screws. This can be inserted into the notch at the coupling and the couplingcan then be turned into the desired position.• Insert the plugs into the coupling housing to prevent the penetration of dirt.9.4.2 OSP-E spindle driveAttentionSome motor systems (e.g., Servo) are to be adjusted in advance before they are connected up to the drive.• Push the location ring (2) over the drive shaft (1) until this is positioned in the cover of the drive. Observeand ensure correct location of the location ring !• Connect the coupling (3) with the drive shaft (1) in such a way that there is a defined clearance “X”, asstated in the table• or make sure that the hex screw at the motor end of the coupling is accessible through the window in thecoupling housing (4).Size Dimension „X“ Dimension „Y“Tighteningtorque25 5 mm 1 mm 0,76 Nm32 15 mm 1,5 mm 1,34 Nm50 13 mm 2 mm 10,5 Nm35

<strong>Modular</strong> <strong>electrical</strong> <strong>linear</strong> <strong>drives</strong> <strong>OSP</strong>-E9 Accessories9.1 Multi-axle systemWith the use of Parker-Origa adapter plates, profile attachments and/or intermediate drive shafts, the connectionof <strong>linear</strong> <strong>drives</strong> in a multi-axle arrangement is possible.Further information on this subject can be found in the <strong>OSP</strong>-E catalogue.9.2 Linear guidesThe Origa System Plus–<strong>OSP</strong>–offers the possibility of adapting various types of guides to the <strong>linear</strong> drive.Further information on this subject is available in the <strong>OSP</strong>-E catalogue or in the separate operating instructionsfor guides and brakes.9.3 Mountings and sensorsWith the help of the <strong>com</strong>prehensive range of Parker-Origa accessories for mounting <strong>com</strong>ponents, the <strong>linear</strong><strong>drives</strong> can be secured depending on the surrounding conditions.With the Parker-Origa sensors, a non-contact scanning of the <strong>linear</strong> <strong>drives</strong> is achieved at end and/or intermediatepositions.Further information on this subject can be found in the <strong>OSP</strong>-E catalogue.9.4 Couplingbox and coupling9.4.1 <strong>OSP</strong>-E belt drive• Push the location ring (6) over the drive shaft (7) until this is positioned in the cover of the drive. Observeand ensure correct location of the location ring !• Connect the coupling (5) with the drive shaft (7) in such a way that there is a defined clearance “X”, asstated in the table• or make sure that the hex screw at the motor end of the coupling is accessible through the window in thecoupling housing (4).• Secure coupling (5) to the drive shaft (7).• Push the coupling housing (4) onto the location ring (6).Size Dimension „X“ Dimension „Y“ Tightening torque<strong>OSP</strong>-E20BHD 6,4 mm 2 mm 10,5 Nm<strong>OSP</strong>-E20BV 6,4 mm 2 mm 10,5 Nm<strong>OSP</strong>-E25BV 13 mm 2 mm 10,5 Nm<strong>OSP</strong>-E25B 14 mm 1 mm 0,76 NmY5 7<strong>OSP</strong>-E32B 10 mm 1,5 mm 1,34 Nm<strong>OSP</strong>-E50B 5 mm 2 mm 10,5 Nm34

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!