12.07.2015 Views

SWAN AMI Codes-II CC - WJF Instrumentation

SWAN AMI Codes-II CC - WJF Instrumentation

SWAN AMI Codes-II CC - WJF Instrumentation

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>SWAN</strong> Analytische Instrumente AGCH-8340 Hinwil/SwitzerlandTel. +41 44 943 63 00swan@swan.ch . www.swan.chMonitor <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>Data sheet no. DenA2544X7XX0Complete monitoring system for the automatic, continuous measurement of free chlorine,monochloramine, total residual chlorine and combined chlorine in potable water,sanitary water and effluent.Monitor <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong> For the continuous online determination of disinfectantsbased on the DPD colorimetric method(EN ISO 7393-2; APHA 4500-Cl G). Measurement values : free chlorine, monochloramine,total residual chlorine, combinedchlorine, flow and if installed pH and temperature. Also applicable for water containing additives likecyanuric acid. Complete system including measurement andcontrol electronics, photometer, flow indicator, reactionchamber, reagent dosing system and reagentcontainers. Integrated pH measurement with temperaturecompensation (available as option). All usual dosing devices for disinfectants and pHcontrol can be connected either through relays oranalog output signals. Two independent controllerscan operate simultaneously. Dosing of disinfectant can be interrupted automaticallywith an external signal, e.g. during sampleflow interruption or filter backwashing. Two (optionally three) selectable measurementvalues are available as analog output signals. Alarm display and activation of alarm relay whenuser defined, critical limits for a measurementvalue are reached. Continuous, automatic monitoring of main instrumentfunctions (dirty photometer, sample flow,reagents). Large back-lit LCD display showing all measuredvalues and status information simultaneously. Factory tested, ready for installation and operation.Options: pH option containing pH sensor, temperaturesensor, cables and electronics board. Chemical cleaning module. For details pleasesee separate data sheet no. DenA82312000.Order scheme Monitor <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong> A – 2 5 . 4 4 X. 7 X. 0 Power supply: 100 - 240 VAC, 50/60 Hz .......................................................................................................................................1 24 VDC, direct current ...........................................................................................................................................2 pH measurement: None .....................................................................................................................................................................0 pH- and integrated temperature measurement ......................................................................................................1 Electrical output options: None .....................................................................................................................................................................0Third current signal output 0/4 - 20 mA ..................................................................................................................1Profibus DP interface ............................................................................................................................................2HyperTerminal interface (for logger download .......................................................................................................3Modbus interface (for Webserver connection .........................................................................................................411/2011 Subject to change without notice DenA2544X7XX0_<strong>AMI</strong>_<strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>.docx


<strong>SWAN</strong> Analytische Instrumente AGCH-8340 Hinwil/SwitzerlandTel. +41 44 943 63 00swan@swan.ch . www.swan.chMonitor <strong>AMI</strong> <strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>Data sheet no. DenA2544X7XX0Disinfectant measurementFree chlorine, monochloramine, totalresidual chlorineMeasuring rangeAccuracy0.00 - 1.00 ppm 0.01 ppm1.00 - 3.00 ppm 0.06 ppm3.00 - 5.00 ppm 0.2 ppmElectrical Connection SchemeCombined chlorine: calculated by thedifference of total residual chlorine andfree chlorine.Measurement time:2 min.Cycle time free chlorine: 1 - 12 min.Cycle time total resid. chlorine: 6 - 60 min.pH measurement (option)Measuring range: pH 2 - 12Resolution:0.01 pHTemperature measurement (Option)with Nt5k sensorMeasuring range : -30 to +100 °CResolution : 0.1 °CTransmitter Specifications andFunctionalityElectronics case:AluminumProtection degree: IP 66 / NEMA 4XDisplay: backlit LCD, 75 x 45 mmElectrical connectors: screw clampsAmbient temperature: -10 to +50 °CLimit range of operation: -25 to +65 °CStorage and transport: -30 to +85 °CHumidity:10 to 90 % relative,non condensingPower supplyVoltage: 100 - 240 VAC ( 10 %),50/60 Hz ( 5 %)or 24 VDC ( 15 %)Power consumption:max. 20 VAOperationEasy operation based on separate menusfor “Messages”, “Diagnostics”,“Maintenance”, “Operation” and “Installation”.User menus in English, German, Frenchand SpanishSeparate, menu specific password protection.Display of process value, alarm statusand time during operation.Storage of event log, and alarm log andcalibration history.Storage of the last 1’500 data records inlogger with selectable time interval.Safety featuresNo data loss after power failure, all datais saved in non-volatile memory. Overvoltageprotection of in- and outputs.Galvanic separation of measuring inputsand signal outputs.Transmitter temperature monitoringWith programmable high/low alarm limits.Real-time clock with calendarFor action time stamp and preprogrammedactions.1 Alarm relayOne potential free contact for summaryalarm indication for programmable alarmvalues and instrument faults.Maximum load:1A / 250 VAC1 InputOne input for potential-free contact. Programmablehold or remote off function.2 Relay outputsTwo potential-free contacts programableas limit switches for measuring values,controllers or timer with automatic holdfunction.Rated load:1A / 250 VAC2 Signal outputs (3 rd optional)Two programmable signal outputs formeasured values (freely scaleable, linearor bilinear) or as continuous control outputs(control parameters programmable).Current loop:Maximum burden:Control functionsRelays or current outputs programmablefor 1 or 2 pulse dosing pumps, solenoidvalves or for one motor valve.Programmable P, PI, PID or PD controlparameters.1 Communication interface(option)RS232 interface for logger download toPC with Microsoft HyperTerminal orRS485 interface (galvanically separated)with Fieldbus protocol Modbus or ProfibusDP.Remote instrument access with PC requiresModbus interface and optionalWebserver.Monitor DataSample conditionsWater consumption: min. 10 l/hWater inlet pressure 0.15 to 2 barSample temperature: 5 to 50 °CFlow cell and connectionsMade of acrylic glass with water inlet filterand needle valve.Openings for pH and temperature sensors.Inlet tubing:6 x 8 mmOutlet pressure: atmospheric drain0/4 - 20 mA Outlet tubing: 15 x 20 mm (1/2")510 PanelPanel dimensions: 400 x 850 x 200 mmPanel material:PVCWeight:9.0 kg11/2011 Subject to change without notice DenA2544X7XX0_<strong>AMI</strong>_<strong>Codes</strong>-<strong>II</strong> <strong>CC</strong>.docx

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!