12.07.2015 Views

P280 brochure EN - Hill-Rom

P280 brochure EN - Hill-Rom

P280 brochure EN - Hill-Rom

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Comfortably safe:<strong>Hill</strong>-<strong>Rom</strong> ® <strong>P280</strong> OverlayComfortably safe.Effective clinical outcomes in the prevention of pressureulcer for risk patients using the <strong>Hill</strong>-<strong>Rom</strong> ® <strong>P280</strong> Overlay.Three zones: Static head zone, alternatinglow or constant low pressure sacrum,dedicated 5° sloped air heel zoneUnlike other typical overlays, <strong>P280</strong> providesdifferentiated zones to address the individualneeds of the patient’s most vulnerable areas.P-maxA firm area at the sacrum zone helps assistwith patient mobilization and bed egress.Easy CPR connectorWith the <strong>Hill</strong>-<strong>Rom</strong> ® <strong>P280</strong> Air Overlay,caregivers simply have to disconnect theconnector from the control unit to create arapid CPR.Safety alarmsCaregivers are informed of any malfunction.Adjustable alternating cycle time andcomfort settingsThe cycle time can be adjusted to adapt tothe patient’s medical condition and providesincreased comfort when sleeping. Comfortsettings help to adjust firmness or softness topatient’s preferences.Automatic Lock-outThis security feature helps maintain thepatient’s prescription unchanged andprevents it being inadvertenly changed.360° welded detachable coverHelps preventing fluid ingress and providesimproved quality as a detachable coveris designed to facilitate cleaning andmaintenance.Transport mode for ten hoursA key benefit to assist caregivers in their dailycare: The static mode ensures the patient issupported when transported to X-rays orother areas of the facility.Manually adjustable with five settingsPressure redistribution is provided inalternating low pressure mode and constantlow pressure mode, adjustable cycle time toadapt to patient’s condition, and to contributeto his increased comfort.Comfort settings help to adjust firmness orsoftness to patient’s preferences. Overinflatingfunction in sit-up-position helps withmobilization. P-max enables nursingprocedures.Technical specificationsMattress OverlayLength:Width:Height:WeightMaximum patient weight:Minimum patient weight:Top cover:203 cm90 cm10 cm± 7,8 kg140 kg30 kgPolyurethaneControl UnitLength:Width:Height:WeightNoise level:29,1 cm20 cm11,7 cm2,2 kg< 45 dB (A)Power supply:AC 220-240 V, 50 Hz, AC 120 V, 50 + 60 HzConsumption: 9,64 W (220-240V, 50 Hz)8,46 W (120V, 60 Hz)10,28 W (120V, 50 Hz)045993/42/EECConformity to standards<strong>EN</strong> IEC 60601-1<strong>EN</strong> IEC 60601-1-2<strong>EN</strong> ISO 13485Doc. No: 5<strong>EN</strong>118301-01 • 2010-08<strong>Hill</strong>-<strong>Rom</strong> and Design and <strong>Hill</strong>-<strong>Rom</strong> word mark are trademarks or registered trademarks of <strong>Hill</strong>-<strong>Rom</strong> Services Inc. Safe Skin and I-mmersion are trademarks orregistered trademarks of <strong>Hill</strong>-<strong>Rom</strong> ®Services Inc.The <strong>Hill</strong>-<strong>Rom</strong> ® <strong>P280</strong> OverlayFrance..................................................................................................................................................................................................................................................+33 (0)2 97 50 92 12United Kingdom..........................................................................................................+44 (0)1530 411000Deutschland.......................................................................................................................................................................+49 (0)211 16450-0Nederland..................................................................................................................................................................................................+31 (0)347 32 35 32Italia............................................................................................................................................................................................................................................................................................................................+ 39 (0)2 950541Suisse/Schweiz.................................................................................................................................+41 (0)21 706 21 30(deutschsprachig).........................................................................................+41 (0)21 706 21 38Österreich...................................................................................................................................................................................................................+43 (0)2243 28550Ireland...........................................................................................................................................................................................................................................................+353 (0)1 413 6005Iberia....................................................................................................................................................................................................................................................................................+34 (0)93 6856000Nordic Countries..........................................................................................................+46 (0)920 47 47 11Export..............................................................................................................................................Contact your local <strong>Hill</strong>-<strong>Rom</strong>distributor or contact your Area Manager viawebsite or call.........................................................................................................................................................................................+1 812 934 8173www.hill-rom.com<strong>Hill</strong>-<strong>Rom</strong> reserves the right to make changes withoutnotice in design, specifications and models. The onlywarranty <strong>Hill</strong>-<strong>Rom</strong> makes is the express written warrantyextended on the sale or rental of its products.© 2010 <strong>Hill</strong>-<strong>Rom</strong> SARL, ALL RIGHTS RESERVED


<strong>Hill</strong>-<strong>Rom</strong> ® <strong>P280</strong> Overlay: Good newsfor your Safe Skin environment.Aligned with the 2009 NPUAP/EPUAP Consensus,<strong>Hill</strong>-<strong>Rom</strong> ® provides highest quality products and therapies toensure the appropriate measures for a Safe Skin environmentfor your patients.Preventing pressure ulcers for your riskpatients just became significantly easier.<strong>Hill</strong>-<strong>Rom</strong> ® I-mmersion Therapy using the 3-Zone <strong>P280</strong> Air Overlay• helps reduce prevalence and incidence of pressure ulcersby using alternating low pressure redistribution and theappropriate amount of immersion• meets the patient’s individual needs through the flexibilityof having the choice of therapies (alternating ormcontinuous low pressure)• provides effective pressure ulcer prevention and treatment• ensures alternating low pressure using highly conformableureth ne bladders• improved patient comfort with adjustable cycle times andfirmness or softness• improves patient and caregiver safety with featuresincluding automatic lock-out, safety alarms andeasy-to-use transport mode• maintains patients’ mobilityAn inadaequte amount of immersiondistributes high pressure on tissue.<strong>Hill</strong>-<strong>Rom</strong> ® I-mmersion Therapy redistributespressure to a larger area, significantlyreducing compression of vulnerable tissue.“Use an active support surface(overlay or mattress) for patientsat higher risk of pressure ulcerdevelopment where frequentmanual repositioning is not possible.”EPUAP/NPUAP Consensus 2009The <strong>Hill</strong>-<strong>Rom</strong> ® <strong>P280</strong> Overlay is perfectly easy to use: Just unfold and secure it on the mattresses’ surface... ...plug in and activate the control unit......and cover with a bedsheet – <strong>P280</strong> is ready to use! Result: Comfortably Safe Skin for your patient.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!