warp/m service manual - ADB Lighting Technologies
warp/m service manual - ADB Lighting Technologies
warp/m service manual - ADB Lighting Technologies
- No tags were found...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
WARP HeadWARP Head8.11 Remove / Change Front Filter cassetteRequired Tool(s) Spare Part Code Preliminary readingScrew Driver PZ2Hexagonal H51001.61.500 None1. Unplug the WARP2. Open the two lenses cover3. Remove the 2 screws M6 on the front4. Remove the Filter Cassette1001.61.500 includes:• 1 Complete Filter Cassette• 2 screws M6 * 30• 2 Locking Washers• 2 Safety Wire AttachmentWARNING:Due to mechanical adjustment, someWARP were manufactured with asmall sheet spacer between the filtercassette and arms.Don’t forget the SafetyWire AttachmentBefore you remove the cassette, makenote of the spacer position, to replaceit correctly.Service Manual - page 90Issue 0.9www.adblighting.com