Motorised Yoke7.26 IR SensorRequired Tool(s) Spare Part Code Preliminary readingScrewdriver PZ11001.65.270 Right1001.65.260 LeftChapter 7.221. Remove the Motor Wing from the WARP (see chapter 7.22)2. Remove the 3 Screws from the motor Wing3. Remove the Plate protection and the IR board.4. Replace the board using new screws and nylon washers (one beneath and one above theboard on each M3 Insert, put blue Loctite 243 on screws)Important:‣ Don’t forget Nylon Washer on each sideof the board (can’t work without)‣ Take care of insulation above the boardNotice:‣ In factory, M3 screws are stop withLoctite Glue 243; if difficult to remove,use a hot air gun to un-stick.1001.65.270 includes:• 1 IR Board Right withInsulation• 4 Screws M3*6 PZ1• 8 Nylon Washer1001.65.260 includes:• 1 IR Board Left with Insulation• 4 Screws M3*6 PZ1• 8 Nylon WasherInsulation stickerCAUTION:‣ It is very important to respectmotors and IR board setting (seechapter 7.26.2)‣ You must have a photoelectriccell in front of each gearNylon Washerswww.adblighting.com Service Manual - page 67Issue 0.9