Motorised Yoke7.13 Replace Coarse PAN AMR SensorRequired Tool(s) Spare Part Code Preliminary readingScrewdriver PZ2 1001.65.230Chapter 7.1Chapter 6.11. Switch OFF and Unplug the WARP2. Disconnect sensor wire3. Remove the 2 Taptite screws4. Replace the Sensor Magnetic using new screws1001.65.230 includes:• 1 Sensor cable• 3 Screws M3*10• 3 Washers + 3 nuts• 2 cable tiesImportant:• The first time you replace AMR SENSOR, youhave to replace all taptite screws By TCBC M4x8ZN DIN 7985-Z.• When you re-start the WARP you have to recalibratePAN AXIS.• This can be started from web page, desk or localdisplay.1001.65.230Note:Distance between sensorand magnet should bearound 1 mm.Service Manual - page 50Issue 0.9www.adblighting.com