warp/m service manual - ADB Lighting Technologies
warp/m service manual - ADB Lighting Technologies warp/m service manual - ADB Lighting Technologies
Motorised Yoke7.5 Replace Front PanelRequired Tool(s) Spare Part Code Preliminary readingFlat ScrewdriverScrewdriver PZ2Wire Cutter1001.65.000Chapter 7.2Chapter 6.11. Remove External connector and Slide Lamp Wire through the Cable Gland2. Disconnect 24 V Power in + WARP Link 1 + GND (from the Board)3. Cut cable tie behind Top Board (which fixes WARP Link 1)4. Disconnect 230 V Power IN from 24 V Power Supply5. Replace the Front Panel1001.65.000 includes:• 1 Front panelassembly• 3 cable tiesImportant:• When you change the Front Panel Board, youhave to enter the correct IP address by meansof the WEB PAGE. The IP address is writtenon the label on the right Arm.• If you replace only this board, you don’t haveto re-calibrate PAN&TILT2Do not disconnectfrom the RelayBoard1001.65.00031Service Manual - page 42Issue 0.9www.adblighting.com
Motorised Yoke7.6 Replace Top Board PCBRequired Tool(s) Spare Part Code Preliminary readingScrewdriver PZ 0.75Flat ScrewdriverOpen ended spanner 5.51001.65.290Chapter 7.5Chapter 6.11. Remove 6 screws from XLR connectors (PZ 0.75)2. Remove 3 screws (Flat)3. Remove 3 spacers and 2 screws(Open ended spanner + Flat)4. Change the boardImportant:• When you change the Top Board, you have to enterthe correct IP address by means of the WEB PAGE.The IP address is written on the label on the right Arm.• If you replace only this board, you don’t have to recalibratePAN&TILTWARNING:• If you replace the top box Board, you have to send itwith the RMA correctly completed. The IP address ofthe WARP is written into the right Arm on a selfadhesive label.1001.65.290 includes:• 7 Screws M3*12• 6 Screws M3*8• 4 Spacers M3*8• 6 Washers• 2 Nut M3• 1 Top Box Board11001.65.29032www.adblighting.com Service Manual - page 43Issue 0.9
- Page 1: Motorised WARPService ManualIssue 0
- Page 4 and 5: IndexIndexFOREWORD ................
- Page 6 and 7: Introduction1 IntroductionAbout Thi
- Page 8 and 9: Tools3 ToolsAdequate tools are requ
- Page 10 and 11: Spare Parts4.2 Spare Parts for the
- Page 12 and 13: Spare Parts4.2.2 Spare Parts for WA
- Page 14 and 15: Spare PartsConnector cable Power 10
- Page 16 and 17: Trouble Shooting5.2 Problems with T
- Page 18 and 19: Trouble Shooting5.4 Problems with S
- Page 20 and 21: Trouble Shooting5.5 Problems with a
- Page 22 and 23: Technical Description6 Technical De
- Page 24 and 25: Technical Description6.2.1 24 V Pow
- Page 26 and 27: Technical Description6.2.3 Boards D
- Page 28 and 29: Technical Description6.3.1.3 PCB 14
- Page 30 and 31: Technical Description6.3.2 Pan & Ti
- Page 32 and 33: Technical Description6.3.8 Descript
- Page 34 and 35: Technical Description6.4 Wheels dri
- Page 36 and 37: Technical DescriptionFunctions:This
- Page 38 and 39: Technical DescriptionFunctions:This
- Page 40 and 41: Motorised Yoke7 Motorised Yoke - Ma
- Page 42 and 43: Motorised Yoke7.3 Open Motor WingRe
- Page 46 and 47: Motorised Yoke7.7 Change Motor Boar
- Page 48 and 49: Motorised Yoke7.9 Replace PCB Shutt
- Page 50 and 51: Motorised Yoke7.11 Replace Top Box
- Page 52 and 53: Motorised Yoke7.13 Replace Coarse P
- Page 54 and 55: Motorised Yoke7.15 Replace Coarse T
- Page 56 and 57: Motorised Yoke7.17 Remove WARP from
- Page 58 and 59: Motorised Yoke7.19 Replace Tilt MOT
- Page 60 and 61: Motorised Yoke7.21 Remove Coarse TI
- Page 62 and 63: Motorised Yoke7.22.2 How to install
- Page 64 and 65: Motorised Yoke7.22.2.2 Left Motor W
- Page 66 and 67: Motorised Yoke7.24 Remove Yoke from
- Page 68 and 69: Motorised Yoke7.25 Replace Pan Belt
- Page 70 and 71: Motorised Yoke7.27 IR Sensor Settin
- Page 72 and 73: Motorised Yoke7.28 Motor WingRequir
- Page 74 and 75: Motorised Yoke7.30 Adjust Motors in
- Page 76 and 77: Motorised Yoke8.1.2 How to place th
- Page 78 and 79: Motorised Yoke8.3 Replace the Refle
- Page 80 and 81: Motorised Yoke8.4.2 How replace the
- Page 82 and 83: WARP HeadWARP Head8.4.2.2 Introduce
- Page 84 and 85: WARP HeadWARP HeadPlace all graduat
- Page 86 and 87: WARP HeadWARP Head8.5 Replace the B
- Page 88 and 89: WARP HeadWARP Head8.7 Replace the B
- Page 90 and 91: WARP HeadWARP Head8.9 Change Gears
- Page 92 and 93: WARP HeadWARP Head8.11 Remove / Cha
Motorised Yoke7.5 Replace Front PanelRequired Tool(s) Spare Part Code Preliminary readingFlat ScrewdriverScrewdriver PZ2Wire Cutter1001.65.000Chapter 7.2Chapter 6.11. Remove External connector and Slide Lamp Wire through the Cable Gland2. Disconnect 24 V Power in + WARP Link 1 + GND (from the Board)3. Cut cable tie behind Top Board (which fixes WARP Link 1)4. Disconnect 230 V Power IN from 24 V Power Supply5. Replace the Front Panel1001.65.000 includes:• 1 Front panelassembly• 3 cable tiesImportant:• When you change the Front Panel Board, youhave to enter the correct IP address by meansof the WEB PAGE. The IP address is writtenon the label on the right Arm.• If you replace only this board, you don’t haveto re-calibrate PAN&TILT2Do not disconnectfrom the RelayBoard1001.65.00031Service Manual - page 42Issue 0.9www.adblighting.com