warp/m service manual - ADB Lighting Technologies
warp/m service manual - ADB Lighting Technologies warp/m service manual - ADB Lighting Technologies
Technical DescriptionFunctions:This board PCB 1525 is designed to:• Control all Motors in the Right Motor Wing: Shutter A, Shutter D, Rear Acc. And FocusComponents:Components you can change on this board are:• Fuse 2A (spare part code 1001.65.300)Reset procedure:When you switch On the WARP/M, all shutter rings will turn automatically to their IR Sensor.When the Silvered index of the ring pass in front of the IR Sensor, the ring stop and go back to the 0position.If the Ring doesn’t stop in front of the IR sensor, the reset has failed.In this case, send a calibration as explain in the user manual.Service Manual - page 36Issue 0.9www.adblighting.com
Technical Description6.4.4 DMX Auxiliary connector (J1)This connector is only mounted on Shield board with the DMX option. The connector is a NEUTRIKNC4FAH (with lock) or NC4FAH-0 (without lock), with the following wiring:1 2 3GND DMX 512 Data – DMX 512 Data+ +24 VDCThe +24 VDC power supply is issued from the internal motor power supply. It is protected through a1A fuse (RAYCHEM Polyswitch) and filtered by a bypass capacitor.The DMX is not terminated nor polarized in the PCB. The board provides standard protection againstelectrostatic discharge (ESD) transients (up to 15kV for 100pF / 1,5kΩ model).6.5 Warplink - Inter Board Communications ProtocolThe link consists of a single RS485 multi-drop bus. Each transceiver on the link is called a "station".6.5.1 Transceivers and TerminationThe link is not terminated since runs are short and configuration is a star, butit is biased at each station so that with transmitters switched off or with the linkdisconnected, a logical 1 is read. An effective circuit is shown in figure. In theclosed system of the Warp there is no need for isolated transceivers. Slewrate limited transceivers should be used.6.5.2 MediumA controlled impedance line is not necessary. However the data pair shouldbe twisted if possible and steps must be taken to ensure that the two wires of the pair are kept closetogether throughout the run.6.5.3 Byte FormatThe protocol uses the 9 bit communications scheme common in microcontrollers, bit 8 is a start ofmessage flag. It is 1 for the first character of a frame and is otherwise 0. This first character issufficient to indicate to receivers whether they have any interest in the ensuing message. If not, areceiver can revert to an idle mode pending the next start of frame character. Data format is 1 startbit, 8 data bits (LSB first), 1 Start of message flag, 1 Stop bit.Link data rate is 125kBaud.6.5.4 WarpLink connectorsThe internal WarpLink connector is a HE14 1x10 connector, with the following wiring:1 2 3 4 5 6 7 8 9 10GND +24V +24V +24V GND data B data A GND Spare 1 spare 2www.adblighting.com Service Manual - page 37Issue 0.9
- Page 1: Motorised WARPService ManualIssue 0
- Page 4 and 5: IndexIndexFOREWORD ................
- Page 6 and 7: Introduction1 IntroductionAbout Thi
- Page 8 and 9: Tools3 ToolsAdequate tools are requ
- Page 10 and 11: Spare Parts4.2 Spare Parts for the
- Page 12 and 13: Spare Parts4.2.2 Spare Parts for WA
- Page 14 and 15: Spare PartsConnector cable Power 10
- Page 16 and 17: Trouble Shooting5.2 Problems with T
- Page 18 and 19: Trouble Shooting5.4 Problems with S
- Page 20 and 21: Trouble Shooting5.5 Problems with a
- Page 22 and 23: Technical Description6 Technical De
- Page 24 and 25: Technical Description6.2.1 24 V Pow
- Page 26 and 27: Technical Description6.2.3 Boards D
- Page 28 and 29: Technical Description6.3.1.3 PCB 14
- Page 30 and 31: Technical Description6.3.2 Pan & Ti
- Page 32 and 33: Technical Description6.3.8 Descript
- Page 34 and 35: Technical Description6.4 Wheels dri
- Page 36 and 37: Technical DescriptionFunctions:This
- Page 40 and 41: Motorised Yoke7 Motorised Yoke - Ma
- Page 42 and 43: Motorised Yoke7.3 Open Motor WingRe
- Page 44 and 45: Motorised Yoke7.5 Replace Front Pan
- Page 46 and 47: Motorised Yoke7.7 Change Motor Boar
- Page 48 and 49: Motorised Yoke7.9 Replace PCB Shutt
- Page 50 and 51: Motorised Yoke7.11 Replace Top Box
- Page 52 and 53: Motorised Yoke7.13 Replace Coarse P
- Page 54 and 55: Motorised Yoke7.15 Replace Coarse T
- Page 56 and 57: Motorised Yoke7.17 Remove WARP from
- Page 58 and 59: Motorised Yoke7.19 Replace Tilt MOT
- Page 60 and 61: Motorised Yoke7.21 Remove Coarse TI
- Page 62 and 63: Motorised Yoke7.22.2 How to install
- Page 64 and 65: Motorised Yoke7.22.2.2 Left Motor W
- Page 66 and 67: Motorised Yoke7.24 Remove Yoke from
- Page 68 and 69: Motorised Yoke7.25 Replace Pan Belt
- Page 70 and 71: Motorised Yoke7.27 IR Sensor Settin
- Page 72 and 73: Motorised Yoke7.28 Motor WingRequir
- Page 74 and 75: Motorised Yoke7.30 Adjust Motors in
- Page 76 and 77: Motorised Yoke8.1.2 How to place th
- Page 78 and 79: Motorised Yoke8.3 Replace the Refle
- Page 80 and 81: Motorised Yoke8.4.2 How replace the
- Page 82 and 83: WARP HeadWARP Head8.4.2.2 Introduce
- Page 84 and 85: WARP HeadWARP HeadPlace all graduat
- Page 86 and 87: WARP HeadWARP Head8.5 Replace the B
Technical Description6.4.4 DMX Auxiliary connector (J1)This connector is only mounted on Shield board with the DMX option. The connector is a NEUTRIKNC4FAH (with lock) or NC4FAH-0 (without lock), with the following wiring:1 2 3GND DMX 512 Data – DMX 512 Data+ +24 VDCThe +24 VDC power supply is issued from the internal motor power supply. It is protected through a1A fuse (RAYCHEM Polyswitch) and filtered by a bypass capacitor.The DMX is not terminated nor polarized in the PCB. The board provides standard protection againstelectrostatic discharge (ESD) transients (up to 15kV for 100pF / 1,5kΩ model).6.5 Warplink - Inter Board Communications ProtocolThe link consists of a single RS485 multi-drop bus. Each transceiver on the link is called a "station".6.5.1 Transceivers and TerminationThe link is not terminated since runs are short and configuration is a star, butit is biased at each station so that with transmitters switched off or with the linkdisconnected, a logical 1 is read. An effective circuit is shown in figure. In theclosed system of the Warp there is no need for isolated transceivers. Slewrate limited transceivers should be used.6.5.2 MediumA controlled impedance line is not necessary. However the data pair shouldbe twisted if possible and steps must be taken to ensure that the two wires of the pair are kept closetogether throughout the run.6.5.3 Byte FormatThe protocol uses the 9 bit communications scheme common in microcontrollers, bit 8 is a start ofmessage flag. It is 1 for the first character of a frame and is otherwise 0. This first character issufficient to indicate to receivers whether they have any interest in the ensuing message. If not, areceiver can revert to an idle mode pending the next start of frame character. Data format is 1 startbit, 8 data bits (LSB first), 1 Start of message flag, 1 Stop bit.Link data rate is 125kBaud.6.5.4 WarpLink connectorsThe internal WarpLink connector is a HE14 1x10 connector, with the following wiring:1 2 3 4 5 6 7 8 9 10GND +24V +24V +24V GND data B data A GND Spare 1 spare 2www.adblighting.com Service Manual - page 37Issue 0.9