Trouble Shooting5.4 Problems with ShuttersImportant: On this chapter, consider that Top Board and 24V Power Supply are working properlyTrouble/Symptom Origin SolutionWARP Link 1 Damaged Control and replace WARP Link 1NOSome shutters don’t respondRight Board is damaged(orange LED is off)NOReplace Board 1001.65.220 (seeChapter 7.7)Left Board is damaged(orange LED is off)Too much dust or oil (fromsmoke machine)NOReplace Board 1001.65.210 (seechapter 7.9)Clean all IR sensors (right and left) withair cleaner or alcoholCalibration on Shutters A andD always failsRight IR sensor is disconnector Right IR sensor cable isdamagedNOControl connection and replace cable ifnecessaryA and D IR Sensor isdamagedToo much dust or oil (fromsmoke machine)Replace Right IR sensor (see chapter7.26)Clean all IR sensors (right and left) withair cleaner or alcoholNOCalibration on Shutters B andC always failsLeft IR sensor is disconnect orLeft IR sensor cable isdamagedNOControl connection and replace cable ifnecessaryA and D IR Sensor isdamagedReplace Left IR sensor (see chapter7.26)Service Manual - page 16Issue 0.9www.adblighting.com