6 Commissioning / Shutdown6.2.3 Internal Display and Operating ElementsMultifunction key T 2Maintenance switch S 1Display of operation (green) LED 6Display of operating mode (green)LED 5OperationMeasurementCalibrationOffset compensation (flashes slowly)With test gas / comparative measurement(flashes quickly)Maintenance mode offMaintenance mode onMaintenance (orange) LED 1 Warning/fault display (red) LED 12® Maintenance mode active® Normal operation® No warning / fault® At least one warning present® At least one fault presentNOTICE!FunctionToggle the displayed warning/ faultReset the displayed warning/faultRapid start-up of the measured gas pump, abortcold-startTrigger an offset calibration or test gas calibrationKey operationPress brieflyPress for longer than 3 sec*Press for longer than 3 sec**Press key for longer than 3 secduring measurement*** Some warnings and faults cannot be reset if the error is still present or the routine is still running.**If at least one warning or fault is still present, the key must be pressed for longer than 6 seconds.33
6 Commissioning / Shutdown6.3 Measurement Start-upWARNING!When installing the probe and during later operation, ensure that the probe does not into contactwith oils, grease or boiler cleaning materials.This applies not just to the cell, but also the connector region!The thread and the clamping ring should be treated with mounting paste type 655 R 1090against seizing.Poisoned or contaminated probes can be identified by an air voltage of -20…-30 mV. In addition,the probe must always be in operation when installed. This avoids the precipitation ofmoisture on the measuring cell, which in certain cases could lead to erroneous measurementsand to the probe's destruction!• Connect the probe but do not install itSwitch to Maintenance either via the display and operating unit in menu "diag” or with themaintenance switch S1Maintenance (orange) LED 1NOTICE!The maintenance switch always has priority.– Maintenance mode active– Normal operation– Maintenance mode off– Maintenance mode on• Switch on voltage• LED 1 shows "Maintenance”• Probe warms up• Cold-start is shownLED 6 "Operation” ONLED 5 "Measurement OFFNOTICE!During cold start the display and operating unit or the monitor output shows/output the cell’sinner resistance R I .The measurement function is operational after 10 minutes.TMeasurement is shownLED 6 "Operation” lights upLED 5 "Measurement " lights upNOTICE!The cold-start delay can be activated from the display and operating unit → "cal” key. Proceedas prompted by the menu, or it can be interrupted by pressing the multifunction key T2 (forlonger than 3 seconds, or if a warning or a fault is still present, for longer than 6 seconds).• Observe the cell’s inner resistance and read the probe voltage alternatively via display andoperating unit (if available) or at the monitor output.34
- Page 1: Quick Reference for End-UsersLambda
- Page 4 and 5: Table of Contents5.3 Wiring Example
- Page 6 and 7: 1 General Information1 General Info
- Page 8 and 9: 2 Safety2.2 For Your Safety2.2.1 Ex
- Page 10 and 11: 2 SafetyUser groupsTwo user groups
- Page 12 and 13: 3 Overview3 Overview3.1 System Over
- Page 14 and 15: 3 Overview3.2 Brief DescriptionUniv
- Page 16 and 17: 4 Technical Description10 LT2 Lambd
- Page 18 and 19: 4 Technical Description4.2.2 Probe
- Page 20 and 21: 4 Technical Description3: Displaya0
- Page 22 and 23: 4 Technical Description12: Analogue
- Page 24 and 25: 4 Technical Description4.5 Options4
- Page 26 and 27: 4 Technical DescriptionMeasurement
- Page 28 and 29: 4 Technical DescriptionDigital outp
- Page 30 and 31: 5 LAMTEC SYSTEM BUS (LSB)5 LAMTEC S
- Page 32 and 33: 6 Commissioning / Shutdown6 Commiss
- Page 36 and 37: 6 Commissioning / ShutdownNOTICE!Re
- Page 38 and 39: 7 Operation7 Operation7.1 Operation
- Page 40 and 41: 7 Operation7.2.3 Liquid Purificatio
- Page 42 and 43: 8 Service and MaintenanceCAUTION!Do
- Page 44 and 45: 9 Faults / Warnings9 Faults / Warni
- Page 46 and 47: 9 Faults / Warnings9.3.1 Faults - C
- Page 48 and 49: 9 Faults / Warnings9.4.2 Offset Vol
- Page 50 and 51: 11 Appendix11 Appendix11.1 Technica
- Page 52 and 53: 11 AppendixTechnical Data Lambda Tr
- Page 54 and 55: 11 Appendix11.3 Electric Connection
- Page 56 and 57: 11 Appendix11.4 Wet/Dry Measurement
- Page 58 and 59: 12 Declaration of Conformity12 Decl
- Page 60: 12 Declaration of Conformity59
6 Commissioning / Shutdown6.3 Measurement Start-upWARNING!When installing the probe and during later operation, ensure that the probe does not into contactwith oils, grease or boiler cleaning materials.This applies not just to the cell, but also the connector region!The thread and the clamping ring should be treated with mounting paste type 655 R 1090against seizing.Poisoned or contaminated probes can be identified by an air voltage of -20…-30 mV. In addition,the probe must always be in operation when installed. This avoids the precipitation ofmoisture on the measuring cell, which in certain cases could lead to erroneous measurementsand to the probe's destruction!• Connect the probe but do not install itSwitch to Maintenance either via the display and operating unit in menu "diag” or with themaintenance switch S1Maintenance (orange) LED 1NOTICE!The maintenance switch always has priority.– Maintenance mode active– Normal operation– Maintenance mode off– Maintenance mode on• Switch on voltage• LED 1 shows "Maintenance”• Probe warms up• Cold-start is shownLED 6 "Operation” ONLED 5 "Measurement OFFNOTICE!During cold start the display and operating unit or the monitor output shows/output the cell’sinner resistance R I .The measurement function is operational after 10 minutes.TMeasurement is shownLED 6 "Operation” lights upLED 5 "Measurement " lights upNOTICE!The cold-start delay can be activated from the display and operating unit → "cal” key. Proceedas prompted by the menu, or it can be interrupted by pressing the multifunction key T2 (<strong>for</strong>longer than 3 seconds, or if a warning or a fault is still present, <strong>for</strong> longer than 6 seconds).• Observe the cell’s inner resistance and read the probe voltage alternatively via display andoperating unit (if available) or at the monitor output.34