Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec
Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec Quick Reference for End-Users Lambda Transmitter LT2 ... - lamtec
5 LAMTEC SYSTEM BUS (LSB)5 LAMTEC SYSTEM BUS (LSB)5.1 Jumpers, LED, Fuses and Terminals1 F6 - T315mA DC5V-LSB2 BR12, BR13 → position „C“3 LED1 – green → RxD from LSBLED2 – yellow → TxD from LSB4 BR101 → Position 1-2 (right) without termination→ Position 2-3 (left) with termination5 Terminal 71 → CAN-GNDTerminal 74 → CAN-HTerminal 75 → CAN-L5.2 FunctionNOTICE!The data transfer of the LT2 only works via LAMTEC SYSTEM BUS, if the device is set to"Measuring" and if it isn’t set to "MAINTENANCE MODE" or "ERROR" .If the communication works properly LED 1 and LED 2 are flickering.29
5 LAMTEC SYSTEM BUS (LSB)5.3 Wiring ExampleMaster ID9 with DisplaySlave ID10 without DisplayLAMTEC SYSTEM BUSBR101: 1-2CAN-HCAN-LCAN-GNDLAMTEC SYSTEM BUSBR101: 2-3CAN-HCAN-LCAN-GNDtermination not active KL. 74KL. 75KL. 71termination activeKL. 74KL. 75KL. 71NOTICE!You must set the master LT (with display) to LSB- device ID 9 and the slave to ID 10 for remotedisplay via LSB (LT-parameter 3801).- It is not possible to connect the master (LT with display) to the remote software and to theremote display at the same time. The connection which is established first takes priority overthe other.- You can use the remote software on the slave LT (LT without display) simultaneously.- You can establish and interrupt the remote connection in the menu diag/remote. You can interruptthe connection at the master and the slave as well.30
- Page 1: Quick Reference for End-UsersLambda
- Page 4 and 5: Table of Contents5.3 Wiring Example
- Page 6 and 7: 1 General Information1 General Info
- Page 8 and 9: 2 Safety2.2 For Your Safety2.2.1 Ex
- Page 10 and 11: 2 SafetyUser groupsTwo user groups
- Page 12 and 13: 3 Overview3 Overview3.1 System Over
- Page 14 and 15: 3 Overview3.2 Brief DescriptionUniv
- Page 16 and 17: 4 Technical Description10 LT2 Lambd
- Page 18 and 19: 4 Technical Description4.2.2 Probe
- Page 20 and 21: 4 Technical Description3: Displaya0
- Page 22 and 23: 4 Technical Description12: Analogue
- Page 24 and 25: 4 Technical Description4.5 Options4
- Page 26 and 27: 4 Technical DescriptionMeasurement
- Page 28 and 29: 4 Technical DescriptionDigital outp
- Page 32 and 33: 6 Commissioning / Shutdown6 Commiss
- Page 34 and 35: 6 Commissioning / Shutdown6.2.3 Int
- Page 36 and 37: 6 Commissioning / ShutdownNOTICE!Re
- Page 38 and 39: 7 Operation7 Operation7.1 Operation
- Page 40 and 41: 7 Operation7.2.3 Liquid Purificatio
- Page 42 and 43: 8 Service and MaintenanceCAUTION!Do
- Page 44 and 45: 9 Faults / Warnings9 Faults / Warni
- Page 46 and 47: 9 Faults / Warnings9.3.1 Faults - C
- Page 48 and 49: 9 Faults / Warnings9.4.2 Offset Vol
- Page 50 and 51: 11 Appendix11 Appendix11.1 Technica
- Page 52 and 53: 11 AppendixTechnical Data Lambda Tr
- Page 54 and 55: 11 Appendix11.3 Electric Connection
- Page 56 and 57: 11 Appendix11.4 Wet/Dry Measurement
- Page 58 and 59: 12 Declaration of Conformity12 Decl
- Page 60: 12 Declaration of Conformity59
5 LAMTEC SYSTEM BUS (LSB)5.3 Wiring ExampleMaster ID9 with DisplaySlave ID10 without DisplayLAMTEC SYSTEM BUSBR101: 1-2CAN-HCAN-LCAN-GNDLAMTEC SYSTEM BUSBR101: 2-3CAN-HCAN-LCAN-GNDtermination not active KL. 74KL. 75KL. 71termination activeKL. 74KL. 75KL. 71NOTICE!You must set the master LT (with display) to LSB- device ID 9 and the slave to ID 10 <strong>for</strong> remotedisplay via LSB (LT-parameter 3801).- It is not possible to connect the master (LT with display) to the remote software and to theremote display at the same time. The connection which is established first takes priority overthe other.- You can use the remote software on the slave LT (LT without display) simultaneously.- You can establish and interrupt the remote connection in the menu diag/remote. You can interruptthe connection at the master and the slave as well.30